Cart  |  Contact  |  Help  | 
1-888-826-6342  | 
US and Canada1-888-826-6342
International1-203-359-1660

Your One-Stop Source for Process Measurement & Control!

fluid flow control

 

Liquid Flow Controllers | FLV400
Very Low Average Power Demand (Approximately 1.25 Watts) Variable Area Flowmeters, Rotameters & Switches - View related products Order Table Description Specs Manuals Reviews Print ... http://www.omega.com/pptst/FLV400.html - 111K - 2/9/2016

MASS FLOW CONTROLLER | GAS FLOW | FMA-LP2600A
Full Scale Ranges from 0.5 SCCM to 500 SLM Response Time of 50 to 100 ms Typical Turndown Ratio of 200:1 Position Insensitive ±0.8% Reading Accuracy RS232 Standard Custom Live Gas ... http://www.omega.com/pptst/FMA-LP2600A.html - 428K - 2/8/2016

Flow Monitors for Corrosive or Ultrapure Fluids Capacities: 0.5 to 7 GPM of Water | FL-X3
Comes complete with operator's manual. Ordering Example: (1) FL-X3 0-3 GPM of Water, Readout increments of 1, 3/4" FNPT connections., $530.00 Keywords: Flow Monitors for Corrosive ... http://www.omega.com/pptst/FL-X.html - 123K - 2/9/2016

Mass Flow Controllers with 20+ Gas Select Function | FMA-2600 SERIES
Full Scale Ranges from 0.5 SCCM to 3000 LPM Response Time of 100 milliseconds Typical Turndown Ratio of 100:1 Typical Position Insensitive Accuracy of ±1% Full Scale RS232 ... http://www.omega.com/pptst/FMA2600_FVL2600.html - 746K - 2/9/2016

Liquid Flow Transmitters With Visual Indication | FPR-200 Series
Pulse output transmitter with clear cover 1/2" NPT, 200 PSIG, 0.5 to 5 GPM Qty 0 FPR204-PS Availability: In Stock $325.00 Blind pulse output transmitter 1/2"NPT, 500 PSIG, 0.5 to 5 ... http://www.omega.com/pptst/FPR200.html - 217K - 2/11/2016

Liquid Flow Transmitter and Switch, Available with 1-1/2" Tri-Clamp Mounting | FSW-9000 Series
Intrinsic safety barriers required for explosion proof areas. Measuring Ranges for FSW-9000 Series The FSW-9000 Series nominal measuring range is 0.04 to 2.0 m/s. The switch can be ... http://www.omega.com/pptst/FSW9000.html - 147K - 2/6/2016

Mass Flow Controller w/RS485 Standard and Alarm Functions | FMA6500 Series
... Vdc and 4 to 20 mA inputs and outputs. Auto Zero The FMA6500 automatically nulls the sensor zero offset whenever the flow setpoint is below 2% of full scale. To accommodate this ... http://www.omega.com/pptst/FMA6500.html - 187K - 2/9/2016

Liquid Flow Through Heaters | FTH Series
The heaters have a titanium element that resists corrosion. The flow through tube is 381 mm (15") long and has 1 1/2 NPT female pipe connections and is available in 304 SS. The ... http://www.omega.com/pptst/FTH.html - 109K - 2/9/2016

PTFE Liquid Flow Sensors | FPR-1500
... Comes complete with 0.9 m (3') long cable with pigtails and operator's manual. Note: Maximum differential pressure (delta P) across flow sensor occurs at maximum rated flow using ... http://www.omega.com/pptst/FPR1500.html - 124K - 2/9/2016

Gas Circulation Heater | GCHCIS Series
Stainless Steel (304) construction of all wetted parts. Thermal Insulation: High temperature pipe insulation inside protective outer jacket. Process Control: Accurate process ... http://www.omega.com/pptst/GCHCIS_HEATER.html - 106K - 2/9/2016




< Previous topic: fluid control valves