Universal Panel Meter / Controller | DP41
Power Consumption: 6 W nom., 10 W max Normal-Mode Rejection: 60 dB Common-Mode Rejection: 120 dB Common-Mode Voltage: 1500 Vp per HV test Resolution: 17-bit Conversion: Dual-slope ... http://www.omega.com/pptst/DP41.html - 183K - 2/5/2016

¼ DIN Temperature/Process Limit Controllers | CN2504 Series
Power Consumption: 5 W/7.5 VA maximum Inputs Thermocouples: J, T, K, L, N, B, R, S, C; Pt Rh 20% vs. Pt 40% Rh RTD: 3-wire, PT100 DC linear (scalable -1999 to +9999) Volts: 0 to ... http://www.omega.com/pptst/CN2504.html - 133K - 2/5/2016

1/8 DIN Temperature/Process Limit Controllers | CN2508 Series
Power Consumption: 5 W/7.5 VA maximum Inputs Thermocouples: J, T, K, L, N, B, R, S, C; Pt Rh 20% vs. Pt 40% Rh RTD: 3-wire, PT100 DC linear (scalable -1999 to +9999) Volts: 0 to ... http://www.omega.com/pptst/CN2508.html - 133K - 2/11/2016

1/16 DIN Temperature/Process Limit Controllers | CN2516 Series
Power Consumption: 5 W/7.5 VA maximum Inputs Thermocouples: J, T, K, L, N, B, R, S, C; Pt Rh 20% vs. Pt 40% Rh RTD: 3-wire, PT100 DC linear (scalable -1999 to +9999) Volts: 0 to ... http://www.omega.com/pptst/CN2516.html - 132K - 2/11/2016

Temperature Controller | CN7600 Series
Two 4-digit, 7-segment 9.53 mm (0.38") H LEDs PV: Red SV: Green Accuracy: ±0.25% span, ±1 least significant digit Supply Voltage: 100 to 240 Vac, 50/60 Hz Power Consumption: 5 VA ... http://www.omega.com/pptst/CN7600_SERIES.html - 121K - 2/9/2016

Limit Process Controller | CN3101
... Specify input code TC, RTD, mV, V or mA. For complete product specifications, including range table for the various inputs choices download the detailed PDF data sheet in the ... http://www.omega.com/pptst/CN3101.html - 128K - 2/5/2016

1/8 DIN Process Meter & Controller | DP25B Series
... Power Options are not field installable. All units come complete with a operator's manual. Part Number Builder (1) (2) (3) DDPP2255BB-- E S -230 -DC10/32 -DC26/56 -A -R -AR -AI-R ... http://www.omega.com/pptst/DP25B.html - 138K - 2/9/2016

Strainmeter, High Performance | DP41-S
The DP41-S has standard built-in excitation. The input range is selected via internal jumpers, and scaling to engineering units is performed using the front keypad. The DP41-S ... http://www.omega.com/pptst/DP41-S.html - 123K - 2/9/2016

Autotune Controller | CN76000 Series
Standard features include self-diagnosis with fault indication. Non-volatile memory retains all process parameters when power is off, without battery backup. Settings for the ... http://www.omega.com/pptst/CN76000.html - 249K - 2/6/2016

Heater Controller | CN7800 Series
Control methods includes on/off, PID, auto-tune and manual-tune. PID control is supported with 64 ramp/soak control actions. Two additional alarm outputs are standard on the CN7800 ... http://www.omega.com/pptst/CN7800.html - 127K - 2/9/2016