The DP2000/9000-M and DP2000-R are low-cost
indicator/controllers for 100 Ω platinumRTD’s with
alpha of 0.00385. They are complete with sensor
excitation and break detection. Resolution can be
1° (DP2000-M) or 0.1° (DP9000-M or DP2000-R).
Readout can be in °C or °F.
POWER AND DISPLAY OPTIONS
Six types of power supplies are available: 120 Vac,
240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and
isolated 26 to 56 Vdc. An LED display is standard,
an LCD display is optional and is recommended for
viewing in bright ambient light. A NEMA 4 (IP65)
splash-proof lens cover is available.
Signal input and power connections are made via a
rear barrier terminal strip. The motherboard rear edge
connector provides access to hold and test, polarity,
clock, and the standard analog output and optional
analog outputs. Decimal point positions can be
selected by jumpers.
ANALOG OUTPUT OPTIONS
A 1 mV/count (±2V full-scale) or 0.1 mV/count (±1V
full-scale) analog output is standard and is ideal for
driving a strip-chart recorder. An additional analog
output can be provided by an optional vertical plug-in
board. Available output signals are 0 to 5 Vdc, 0 to
10 Vdc, 0 to 1 mA (source or sink) and 4 to 20 mA
(source or sink). The top and bottom of each output
range can be scaled to fit a user-selected display span.
CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal
upper board. Available options include single-setpoint
control with one 10 A relay, dual-setpoint control
with two 10 A relays, 4 to 20 mA proportional control
(source or sink), time-proportional 2 A solid-state relay
control, and isolated, parallel BCD output.
SPECIFICATIONS Analog Input RTD Type: 100 Ω platinum with alpha of 0.00385 Calibration: To DIN 43760, October 1980 Excitation Current: 0.42 mA (DP2/9M), 4.2 mA (DP2/9R) Sensor Connection: 2, 3 or 4 wires Maximum Lead Resistance: 20 Ω for 2, 3 or 4-wire connection Zero Adjustment: ±5°C (±9°F) Overvoltage Protection: 15 Vp Analog-to-Digital Conversion (DP9 only) Input Configuration: Differential, Bipolar Technique: Dual-slope, average-value Polarity: Automatic Signal Integration Period: 100 ms, nominal Read Rate: 2.5/s Display LED: Red, 14.2 mm (0.56"), 7-segment LCD: 12.7 mm (0.50"), 7-segment Power AC Models: 120, 240 or 24 Vac 10%/-15%, 49 to 440 Hz DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated Common Mode Voltage: 1500 Vp test (354 Vp per IEC spacing) Rejection: 120 dB Environmental Operating Temperature: 0 to 60°C (32 to 140°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Humidity: 95% RH, noncondensing @ 0 to 40°C (32 to 104°F) Mechanical Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31") Depth Behind Bezel: 139.8 mm (5.50") Panel Cutout: 92 W x 45 mm H (3.62 x 1.77") Weight: 17 oz (480 g) Case Material: 94V-0 UL-rated polycarbonate
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual. Ordering Example: (1) DP2101-M2 3-1/2 digit RTD meter, LCD, 120 Vac power, dual setpoint (10A relay), 1.0°F resolution, -328 to 1526°F, $530.00, plus (1) DP2000-M1 3-1/2 digit RTD meter, red LED, 120 Vac power, 1.0°C resolution, -200 to 830°C, $315.00, $530.00 + 315.00 = $845.00
Part Number Builder
Option Descriptions
(1)
Display Resolution and Case Style
Select 2 for ±1999 counts (3 1/2 digits) 9 for ±9999 counts (4 digits)
(2)
Display & Power Options
Select 0 for LED 120 Vac (49/440 Hz) (BQ20 or BQ90) 1 for LCD 120 Vac (49/440 Hz) (BQ21) 2 for LED 240 Vac (49/440 Hz) (BQ22 or BQ92) 3 for LCD 240 Vac (49/440 Hz) (BQ23) 4 for LED 9-32 Vdc (isolated) (BQ24 or BQ94) 5 for LCD 9-32 Vdc (isolated) (BQ25) 6 for LED 5 Vdc** (BQ26 or BQ96) 7 for LCD 5 Vdc** (BQ27) 8 for LED 24 Vac (BQ28 or BQ98) 9 for LCD 24 Vac (BQ29) A for LED 26-56 Vdc (isolated) (BQ2A or BQ9A) B for LCD 26-56 Vdc (isolated) (BQ2B)
(3)
Analog Outputs
Select 0 for 1mV/count (DP2) or 0.1mV/count (DP9) analog output (standard) 1 for 0-5 Vdc non-isolated (BA01) 2 for 0-10 Vdc non-isolated (BA01) 3 for 0-1 mA source or sink non-isolated (BA01) 4 for 4-20 mA source or sink non-isolated (BA01) 5 for 4-20 mA sink (high-compliance) non-isolated. (BA02) 6 for 4-20 mA ISOLATED (BA03)
(4)
Control Outputs
Select 0 for None 1 for Dual-setpoint 10 A relay. (BDT1) 2 for Proportional 4-20 mA control source or sink (BDP1) 3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control source or sink. (BDP2) 4 for BCD (isolated latched buffered byte addressable). Includes 50-pin mass-termination connector. (BDD2) 5 for Single-setpoint 10 A relay (BDS1)
(5)
Input Type and Range
Select M1 for RTD (Pt 100) input (BSCM) -200 to +830°C (DP2) or -200.0 to +830.0°C (DP9) (BSCM) M2 for RTD (Pt 100) input (BSCM) -328 to +1526°F (DP2) or -328.0 to +999.9°F (DP9) (BSCM) R1 for RTD (Pt 100) input (BSCM) -199.9 to 199.9°C (DP2). Not Recommended for DP9 (BSCR) R2 for RTD (Pt 100) input (BSCM) -199.9 to 199.9°F (DP2). Not Recommended for DP9 (BSCR)
(6)
Display Color
Select Nothing(leave field blank) for for Red Display (standard) -G for Green Display
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
Keywords:RTD Meters, Indicators/Controllers, 1/8 DIN