Loop Powered and Four-Wire Ultrasonic Level Transmitters |
| LVU1500 Series Ultrasonic Level Transmitters |
|
 |
|
Loop Powered and Four-Wire Ultrasonic Level Transmitters
 |
| Click for larger image. |
|
|
|
|
| |
0.3 to 7.6 m (1 to 25') Range
|
| |
Exclusive VSS Sensor Sense™ with 3/4" NPT Mounting
|
| |
Programmable Zero and Span Through BCD Switches
|
| |
Direct Replacement of Capacitance System
|
| |
CSA Approval, Intrinsically Safe and Explosion Proof Rating with 316SS Sensor, PTFE, Tefzel®, Sensors
|
| |
STD Near Zone Varies from 152.4 to 305 mm (6 to 12")
|
View related products - Level Measurement
|
| |
|
|
|
 |
The LVU1500-LP Series Two-Wire ("Four-Wire" for four wire unit),
non-contact continuous level
transmitter, is easy to program, can
be used in hazardous locations, and
offers unique stainless steel and ¾
NPT sensors. It is a great choice for
sanitary, hazardous, dirty, corrosive
or high purity processes. The 4 to
20 mA output is compatible with all
control systems and updates quickly
making the LVU1500 Series the
right choice for fast filling processes.
The LVU1500 Series is plug-andplay.
Digital signal processing,
and automatic temperature
compensation eliminates all
adjustment except zero and span.
Zero and span calibration is set
directly in inches using digital
switches and requires no power.
The rugged epoxy coated aluminum
enclosure survives where plastic
enclosures fail.
Operation
The sensor is mounted on the top
of the tank. The electronics
generate an electronic signal that is
converted by the sensor to
ultrasonic pulses that are
transmitted through air space.
At the liquid/air interface, the pulses
are reflected back to the sensor.
These echoes are received by the
microprocessor in the electronics,
which samples the echoes and
calculates the level in the tank.
A continous output of 4 to 20 mA
(isolated) adjustable in increments
of 1"/0.1" over entire span is
provided to satisfy a number of
applications. Programming is done
through a pair of BCD switches.
SPECIFICATIONS
Range: 0.3 to 7.6 m (1 to 25')
Accuracy analog output: 0.25% of full scale
Repeatability:
Four Wire: 3.2 mm (1/8") typical
Loop Power: ±0.13 mm (±0.005") typical
Input Power:
Four Wire: 24 Vdc
Loop Power: 18 Vdc to 36 Vdc
Two Wire: Loop Power
Output Signal:
Four Wire: 4 to 20 mA DC (isolated), 2 to 10 Vdc
Loop Power: 4 to 20 mA DC (isolated)
Lost Echo Indicator:
Four Wire: LED Flashes
Two Wire: LED Flashes and output at 22.0 mA
Temperature Compensation: Automatic over full range of sensor operating temperature
Controls: Programmable zero and span, height & distance-mode through BCD switches increments of 25 mm (1") up to 7.6 m (300"), increments of 2.5 mm (0.1") up to 2.5 m (99.9")
Temperature Range:
Sensor: -29 to 82°C (-20 to 180°F),
Electronics: -29 to 77°C (-20 to 170°F)
Sensor Pressure Rating:
316LSS: 17.2 bar (100 psig)
ETFE:6.9 bar (40 psig)
Sensor Construction: ETFE or 316SS or PTFE
Electronics Enclosures: NEMA-4/7 Explosion-Proof: Class I, Divisions 1 or 2 Groups B, C & D, Class II, Divisions 1 and 2, Groups E, F & G, Class III Cenelec, CSA & UL Approved
Mounting: ¾"
NPT and Sanitary: Up to 3 m (10')
2 NPT: Up to 6 m (20')
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes with complete operator’s manual.
Ordering Example: (1) LVU1502-LP loop powered transmitter with 1” sanitary fitting, (1) CNI3233 1/32 DIN controller = $1,228.00
|
|
 |
|
 |
|  |
|
Keywords.:Loop Powered and Four-Wire Ultrasonic Level Transmitters
|