The OM-CP-BRIDGE110 is a
miniature battery powered, stand
alone, bridge/strain gage data logger.
The OM-CP-BRIDGE110
features a real-time clock module
that extends the battery life to more
than 10 years (15 minute reading
rate at 25°C) and allows for high
speed downloads. This is an all-in-one
compact, portable, easy-to-use
device that will measure and record
up to 32,767 measurements. The storage medium is
non-volatile solid state memory,
providing maximum data security
even if the battery becomes
discharged. The device can be
started and stopped directly from
your computer and its small size
allows it to fit almost anywhere. The
OM-CP-BRIDGE110 makes data
retrieval quick and easy. Simply
plug it into an available COM port and
our user-friendly software does the
rest. The software converts your PC
into a real time strip chart recorder.
Data can be printed in graphical or
tabular format and can be exported
to a text or Microsoft Excel file.
SPECIFICATIONS Input Connection: 6-position
removable screw terminal Input Impedance:
1 Mduring acquisition,
low impedance when inactive Reference Voltage Output: 2.5 Vdc,
2.5 mA (1 k) maximum load Maximum Input Signal
Impedance: 5 k (350 .sensors
may be used with series resistors toproduce >1 K; 120 .gages may
be used in half and quarter bridge
configurations) Temperature Effect on Span and
Offset: <25 µV over -40 to 80°C Engineering Units: Stored in
device, user may define any desired
scale and offset from ±1.000E-31 to
±9.999E+31 Start Time: Start time and date are
programmable through software up
to six months in advance Real Time Recording:
Device may be used with PC to
monitor and record data in real time Memory: 32,767 readings Recording Interval: 1 reading
every 2 seconds to 1 every 12 hours Calibration: Digital calibration
through software Calibration Date: Automatically
recorded within device to alert user
when calibration is required Battery Life: 10 years at 15 min
reading rate, 25°C Power: 3.6 V lithium battery
included Data Format:
Date and time stamped, %, ppm;
e, µe, V, mV, µV engineering units
specified through software Time Accuracy: ±1 minute per
month at 20°C to 30°C) Computer Interface:
PC serial, RS-232C COM or USB
(interface cable required);
56,600 baud Software: XP SP3/Vista and 7
(32 and 64-bit) Operating Environment:
-40 to 80°C (-40 to 176°F)
0 to 95% RH non-condensing Dimensions:
42 H x 68 W x 20 mm D
(1.7 x 2.7 x 0.8") Weight: 60 g (2 oz)
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 3.6V lithium battery. Operators manual and interface cable are included with the OM-CP-IFC200 software/cable package (required for data logger operation, sold separately). Ordering Example: (1) OM-CP-IFC200 Windows software and 1.8 m (6') USB interface cable, $129.00