Wireless Humidity and Temperature Monitoring and Alarming System |
| OM-CP-THERMALERT-RH |
|
 |
|
|
|
|
|
$
269.00
OM-CP-THERMALERT-RH
|
|
| |
|
|
|
 |
The OM-CP-THERMALERT-RH
is a humidity and temperature
monitoring and alarming system,
designed specifically for
laboratories, warehouses and
other environments where humidity
monitoring is critical. The system
can be used to monitor a single
temperature location or expanded
to include hundreds of locations by
adding additional transmitters.
The OM-CP-THERMALERT-RH
provides real time notification of
humidity and temperature
deviations, and features a user
programmable alarm that can be
configured to send a message via
text message, screen alarm/or
e-mail if an alarm condition occurs.
The OM-CP-THERMALERT-RH
system is equipped with wireless
two-way communication. Full
communication can be performed
directly from a central PC, including
starting, stopping and downloading.
In addition to wirelessly transmitting
data, OM-CP-THERMALERT-RH
also stores each reading to internal
memory for backup. This back up
data may be retrieved wirelessly at
a later time. Customers can setup
automatic archiving preferences,
ensuring all data is saved and
retained to comply with federal
regulations.
Specifications
TEMPERATURE
Sensor: Semiconductor
Range: -20 to 80°C (-4 to 176°F)
Resolution: 0.01°C (0.18°F)
Calibrated Accuracy: ±0.5°C
(0.9°F) 0 to 150°C (32 to 122°F)
HUMIDITY
Sensor: Semiconductor
Range: 0 to 95% RH
Resolution: 0.1% RH
Calibrated Accuracy: ±3.0% RH
[±2% RH typical at 25°C (77°F)]
WIRELESS
RF Frequency: 2.45 GHz IEEE
802.15.4 ultra-low power wireless
transceiver with fully bi-directional
communication
Band: ISM band 2.405-2.48 GHz
Output Power: +0dBm typical
Transmitter Range (to Receiver or Repeater):
Outdoor Line-of-Sight 122 m (400')
Indoor: 46 m (150')
GENERAL
Reading Rate: One reading every
two seconds to one every 24 hours
Memory: 15,000 readings; software
configurable memory wrap
Wrap Around: Yes
Start Modes:
• Immediate start
• Delay start up to 18 months
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery
(included); user replaceable
Battery Life: 2 years typical
Data Format: Date and time stamped ºC, ºF, K, ºR
Time Accuracy: ±1 minute/month (at 25°C)
Computer Interface: OM-CP-RFC1000 required;
115,200 baud
Software: XP SP3/Vista/Windows® 7 (32- and 64-bit)
Operating Environment:
-20 to 80ºC (-4 to 176ºF), 0 to 95% RH non-condensing
Dimensions: W x 127 L x 33 mm D
(2.2 x 5.0 x 1.3")
Enclosure Material: ABS plastic
OM-CP-RFC1000 Transceiver
(Acts as Receiver or Repeater)
Sensitivity: -95 dBm typical
Max Number of Transmitters:
Up to 20 transmitters sending data
directly to the transceiver
or up to
300 transmitters using additional
transceivers
(20 transmitters per transceiver)
Max Distance to Transceiver or from one Transceiver
Outdoor Line-of-Sight: 122 m (400')
Indoor: 46 m (150')
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 3.6V lithium battery
Ordering Example: (1) OM-CP-THERMALERT-RH-CERT Wireless humidity and temperature transmitter with NIST calibration certificate, $329.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Manual
|
 |
 |
 |
 |
 |
 |
|
Product Manual
|
|
Download
OM-CP Series - Data Logger and Software User Guide
|
|
Download
OM-CP Series - Data Logger Quickstart Guide
|
|
|
 |
 |
|
|