Model OMA-VM500-6 monitors up to eight
switch closures (dry contacts) which
allows you to connect a wide variety of
sensors such as magnetic door or window
switches, thermostats, fluid level switches
and motion sensors. The OMA-VM500-6
allows you to program a "normal" state
and a time delay for each dry contact
input. A five-second message can be
recorded to define each input. An
additional local identification message can
be recorded to identify the OMA-VM500-6
dialer. When an input is different from the
programmed "normal" state for longer
than the time delay, the unit will dial up to
four phone or pager numbers. The
integrated voice tells you which zone is in
alarm and the current status. You can call
the unit at any time to hear a status report
including power status. All programming is
accomplished over the phone following
simple voice instructions.
When the OMA-VM500-6 goes into an
emergency state it will energize the alarm
relay, activate the alarm buzzer and begin
making emergency calls. When the unit
dials a voice number it will first play the
local identification message and the
current status of any inputs which caused
the emergency state. The unit ceases to
be in the emergency state once contact is
made with the unit.
Contact is made when the user enters
the four digit PIN number, or if the user
is on site by pressing the cancel button
located on the front of the dialer. If the
input(s) return to the programmed
"normal" states, the unit will also cease
to be in the emergency state.
Remotely Controlled Alarm Relay Option
Models with this option contain an alarm relay that may be controlled from a remote location through a standard
touch tone telephone.
Specifications
Number of Inputs: 8
Input Type: dry contact, NO or NC
Telephone: standard RJ11 phone jack
connection
Telephone Numbers: stores up to four
phone numbers up to 20 digits long
Personal Identification Message:
record up to a 5-second message that
identifies the dialer
Individual Channel Identification
Messages: record up to a 5-second
identification message for each input
Operation: operates with answering
machine on the same phone line
Alarm Notification:
alarm buzzer sounds and alarm
relay closes if any input(s) go into
an alert condition
Alarm Cancellation: pushbutton on
front of the unit silences the alarm and
cancels emergency telephone calls
Alarm Relay Output: 5A, 250 Vac
Alarm Relay Operation: energized
during an emergency state; optional
control via touch tone phone (model
OMA-VM500-6R)
Power: powered from included 120 Vac
wall mount transformer power supply
Battery Backup: 4-hour rechargeable
battery backup; 20 or 30 hours
optional
Operating Ambient: 0 to 52°C
(32 to 125°F)
Electrical Connections: plug-in
terminal block
Dimensions: 117 mm H x 223 mm W
x 57 mm D (4.62 x 8.79 x 2.26")
Material: ABS Plastic
Weight: 0.9 kg (2 lb)
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Each unit is supplied with complete user’s manual.
Ordering Example: (1) OMA-VM500-6 Eight channel automatic dialer = $355.00
|
|
 |
|
 |
|  |
|