OMEGA’s new OS100E Series
miniature infrared transmitters measure
a temperature range of -18 to 538°C
(0 to 1000°F). They consist of a
remotely mounted infrared sensor
head connected to a high-performance,
microprocessor-based signal
conditioner. The miniature sensor
head is ideal for measuring
temperature in confined, hard-to-reach
places and harsh environments.
The sensor head is connected to
the main electronics housing via a
1.8 m (6') shielded cable. The signal
conditioner’s main electronics are
mounted in a rugged NEMA 4 (IP65)
rated die-cast aluminum housing.
Model OS102E includes a built-in
LED display that is switchable
between °C and °F. Standard
features include adjustable emissivity,
field-adjustable alarm output, and
RS232 PC interface. The unit has
analog outputs such as 4 to 20 mA,
0/5 Vdc, 0/10 Vdc, 1 mV/degree, and
Type K thermocouple.
SPECIFICATIONS Temperature Range: -18 to 538°C (0 to 1000°F) Accuracy: ±2% rdg or 2.2°C (4°F), whichever is greater; ( @ 22°C (72°F) Ambient Temperature and Emissivity ≥0.95 Optical Field of View: 6:1 (distance/spot size) Sensor Head Cable Extension: Up to 15 m (50') total Repeatability: ±1% rdg Spectral Response: 5 to 14 microns Response Time: 100 ms (0 to 63% of final value) Emissivity Range: 0.1 to 1.00, adjustable Display Option (102E): 4-digit LED, °C/°F switchable Operating Ambient: Main Transmitter: 0 to 50°C (32 to 122°F)
Sensor Head: 0 to 70°C (32 to 158°F) Sensor Head (-HT Model): 0 to 85°C (32 to 185°F) Sensor Head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F) Relative Humidity: Less than 95% RH, non-condensing Water Flow Rate for OS100-WC: 0.25 GPM, room temperature Thermal Shock: About 30 minutes for 25°C (77°F) abrupt ambient temperature change Warm-Up Period: 3 minutes Air Flow Rate for OS100-AP: 1 CFM (0.5 L/s) Power: 12 to 24 Vdc @ 150 mA PC Communications: Serial RS232, 2-way Analog Outputs: MV: 1 mV/degree K: K Type thermocouple MA: 4 to 20 mA V1: 0 to 5 Vdc V2: 0 to 10 Vdc Output Load Requirements: Min Load: 1 kΩ (0 to 5 Vdc), 2 kΩ (0 to 10 Vdc) Max Load (4 to 20 mA): (supply power - 4)/20 mA Transmitter Housing: NEMA 4 (IP65), die-cast aluminum Sensor Head Housing: NEMA 4 (IP65), aluminum Alarm Output: Open drain, 100 mA Alarm Setpoint: 0 to 100%, adjustable Alarm Deadband: 5.5°C (10°F) Dimensions: Sensor Head: 25.4 OD x 63.5 mm L (1 x 2.5") Main Housing: 65.5 W x 30.5 H x 115.3 mm L (2.58 x 1.2 x 4.54") Weight: 272 g (0.6 lb)
LASER SIGHT ACCESSORY (OS100-LS) Wavelength (Color): 630 to 670 nm (red) Operating Distance (Laser Dot): Up to 9.1 m (30') Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperature European Classification: Class 2, EN60825-1/11.2001 Max Operating Current: 45 mA @ 3 Vdc FDA Classification: Complies with 21 CFR 1040.10, Class II Laser Product Beam Diameter: 5 mm Beam Divergence: <2 mrad Operating Ambient: 0 to 50°C (32 to 122°F); <95% RH, non-condensing Power Switch: On/off slide switch on the battery pack Power Indicator: Red LED Power: Battery pack, 3 Vdc (consists of two 1.5 Vdc "AA") Software (included): Requires Windows 98 or newer operating system
† All dollar amounts on this site are shown in US currency.
Note: Each model comes with sensor head and 1.8 m (6') cable, sensor head mounting nut, main electronics housing, user software and operator’s manual. Ordering Example: (1) OS101E-MA transmitter with 4 to 20 mA output,, $245.00, plus (1) OS100-LS laser sighting accessory, $175.00, plus (1) OS100-CA15FT 4.6 m (15') sensor head extension cable, $35.00, $245.00 + 175.00 + 35.00 = $455.00