Fast Response Infrared Fiber Optic Thermometer/Transmitter with Local Display and Analog Output |
| OS1592 |
|
 |
|
|
Fast Response Infrared Fiber Optic Thermometer
 |
| Click for larger image. |
|
|
|
|
| |
For Both Hard to Reach and Polymer Bolt Applications
|
| |
Accuracy 1% of Reading
|
| |
Models with Temperature Ranges Measuring up to 4500°F (2482°C)
|
| |
Current, Voltage, Millivolt or Thermocouple Output
|
| |
°C/°F Keypad Selectable
|
| |
Local Backlit LCD Display Standard
|
| |
Dual Display Indicates Current Plus Min, Max, or Differential Temperatures
|
| |
Visual Alarm as well as a built-in Relay output
|
| |
Emissivity Adjustable from 0.05 to 1.00 in 0.01 steps set via the keypad
|
| |
25 msec Response time (0 to 63% of Final Value)
|
| |
Complete NEMA-4 System
|
| |
Safe and Easy to Install
|
View related products - Pressure Transducers
|
| |
|
|
|
 |
View and download our custom infrared questionnaire.(pdf)
OMEGA’s new CE marked low cost OS1590 Series infrared fiber optic thermometer/ transmitter
system measures temperature ranges up to 4500 F and provides
dual analog outputs (4-20 mA, 0-5 VDC, 0-10 VDC, 1 mV/ Degree, J & K T/C)
electrically isolated from the DC power supply input. The main Electronics is in a
NEMA 4 rated Aluminum housing with a local backlit LCD, built-in Relay, and a 4 position
programmable keypad.
SPECIFICATIONS
Temperature Range:
-R1: 260 to 538°C (500 to 1000°F)
-R2: 538 to 1093°C (1000 to 2000°F)
-R3: 1093 to 2482°C (2000 to 4500°F)
Accuracy: 1% of rdg
Repeatability: 0.75% of rdg
Response Time: 25 msec (0 to 63% of final value)
Emissivity: 0.05 to 1.00 adjustable,
set via keypad
Spectral Response: 0.8 to 1.8 microns
Analog Output: 1 mV/deg, standard
Second Analog Output: 0 to 5 Vdc, 0 to 10 Vdc,
4 to 20 mA, or Type J or K thermocouple
Display: Backlit Dual LCD
Keypad: 4 position, tactile feedback membrane switch
Calculated Temperature Values:
Maximum, minimum, differential
High Alarm: Set via keypad
with built-in relay
Relay Contact Rating:
5 A @ 28 Vdc
Operating Ambient
Temperature:
0 to 50°C (32 to 122°F)
Enclosure: Die cast
aluminum, NEMA-4
DIMENSIONS
Main Housing:
8.9 W x 5.6 H x 11.4 L cm
(3.5 x 2.2 x 4.5")
Optical Assembly: L1- Lens:
2.5 Dia. x 15.9 cm (1 x 6.25")
L2- Ceramic Tip: 0.47 Dia. x 15.2 cm (0.187 x 6")
L3- Polymer Bolt: 0.95 Dia. x 10 cm (0.375 x 4")
Power: 18 to 36 Vdc
| Model Number | Temperature Range | Optical Assembly, Spot Size | Cable Length |
| OS1592-L1-R1-1-(*) | 260 to 538°C (500 to 1000°F) | Lens Probe, 6.35 mm @ 203.2 mm (0.25" @ 8") | 1.5 m (5') |
| OS1592-L2-R1-(*) | 260 to 538°C (500 to 1000°F) | Ceramic Tip, 152.4 mm (6") Probe | 1.5 m (5') |
| OS1592-L3-R1-(*) | 260 to 538°C (500 to 1000°F) | Polymer Bolt, 101.6 mm (4") Probe | 1.5 m (5') |
| OS1592-L1-R2-1-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 6.35 mm @ 203.2 mm (0.25" @ 8") | 1.5 m (5') |
| OS1592-L1-R2-2-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 4.83 mm @ 508 mm (0.19" @ 20") | 1.5 m (5') |
| OS1592-L1-R2-3-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 1.93 mm @ 152.4 mm (0.076" @ 6") | 1.5 m (5') |
| OS1592-L2-R2-(*) | 538 to 1093°C (1000 to 2000°F) | Ceramic Tip, 152.4 mm (6") Probe | 1.5 m (5') |
| OS1592-L3-R2-(*) | 538 to 1093°C (1000 to 2000°F) | Polymer Bolt, 101.6 mm (4") Probe | 1.5 m (5') |
| OS1592-L1-R3-2-(*) | 1093 to 2482°C (2000 to 4500°F) | Lens Probe, 4.83 mm @ 508 mm (0.19" @ 20") | 1.5 m (5') |
| OS1592-L1-R3-3-(*) | 1093 to 2482°C (2000 to 4500°F) | Lens Probe, 1.93 mm @ 152.4 mm (0.076" @ 6") | 1.5 m (5') |
(*) Specify second analog output: -J = Thermocouple output, Type J (For R1 Temp range only); -K = Thermocouple output, Type K (For R1& R2 Temp
range only); -mA = 4 to 20 mA output; -V1 = 0/5 Vdc output; -V2 = 0/10 Vdc output. This unit provides two separate analog outputs. The first is 1mV/Deg.
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Optical Assembly
|
| |
Select L1 for lens probe L2 for ceramic tip L3 for polymer bolt
|
(2)
|
Temperature Range
|
| |
Select R1 for 260 to 538°C (500 to 1000°F) R2 for 538 to 1093°C (1000 to 2000°F) R3 for 1093 to 2482°C (2000 to 4500°F)
|
(3)
|
Part Number Code(see table above)
|
| |
Select Nothing(leave field blank) for no option -1 for code 1 -2 for code 2 -3 for code 3
|
(4)
|
Analog Output
|
| |
Select mA for 4-20mA V1 for 0-5Vdc V2 for 0-10 Vdc J for J thermocouple(R1 range only) K for K thermocouple(R1 and R2 range only)
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
 |
|
|
 |
|  |
|
Keywords.:Fast Response Infrared Fiber Optic Thermometer/Transmitter with Local Display and Analog Output
|
Back to top
|
|
|