Handheld Pressure Calibrators with Interchangeable Pressure Modules |
| PCL-1B |
|
 |
|
|
|
 |
The OMEGA ® PCL-1B handheld system introduces a new era in pressure calibration standards.
This unique instrument measures pressure, flow, vacuum, leak, current, voltage and change-of-state
for switch testing. A fully equipped PCL-1B system provides all calibration capabilities needed in
virtually all pressure measurement and test applications. Each handheld system consists of a base
unit and one or two plug-in pressure modules. An array of pressure modules is available to cover
ranges from 0.25 inches H2O through 7500 psi. Modules can be interchanged quickly and easily
without the use of tools. Select any combination of modules to meet your application needs. The
PCL-1B pressure calibration and test system combines the capabilities of plug-in pressure modules
with a wide selection of standard firmware features. This combination of firmware-related features and
unlimited pressure sensor interchangeability make the PCL-1B one of the most powerful pressure
calibration and test instruments available today.
SPECIFICATIONS
Available Accuracies (% of span compared to standard): ±0.07% of span
(ranges below 1 in H2O) ±0.06% of span (from 0/1 through 0/200 in H2O)±0.05% of span (psi ranges only)
Repeatability: * ranges 0/5 psi and above ±0.02% of span (typical) ranges 0/2 psi and below ±0.05% of span
Sensitivity: * + 0.002% of span with damping 1 part in 50,000 (max)( * included in accuracy specifications) Operating Temp. Range: 0 to 49°C (32 to 120°F) Compensated Temp. Range: -7 to 49°C (20 to 120°F) Reference Temperature: 21°C ±1.7°C (70° ±3°F) Temperature Error: maximum of ±0.007% of span per over the compensated range for zero and span Storage Limits: -20 to 70°C (-4 to 158°F) Display: Alphanumeric LCD, 9.4 mm (0.37") height per 2 lines, 16 characters/line Display Update: 100 ms Process Connection: 1 /8 NPT, internal thread Electrical Connection: Miniature recessed banana jacks Housing: Molded, high-impact ABS case, gray Weight: Base unit: 1.3 kg (2.2 lb) Pressure Module: 0.3kg (0.5lb) each Dimensions: 200 L x 108 W x 83 mm H (7.88 L x 4.24 W x 3.25" H) nominal Power Supply: Internal: 9 Vdc batteries (2 required) included External: ac adaptor 9 Vdc, 500 mA Portable Operation: 30 hours on two 9 Vdc alkaline batteries
PLUG IN PRESSURE MODULES (psi) RANGES |
| GAGE PRESSURE |
| MODEL NO. | RANGE (psig) |
| PCL-MB-005G | 0-5 |
| PCL-MB-010G | 0-10 |
| PCL-MB-015G | 0-15 |
| PCL-MB-020G | 0-20 |
| PCL-MB-030G | 0-30 |
| PCL-MB-050G | 0-50 |
| PCL-MB-100G | 0-100 |
| PCL-MB-250G | 0-250 |
| PCL-MB-300G | 0-300 |
| PCL-MB-500G | 0-500 |
| PCL-MB-600G | 0-600 |
| PCL-MB-1KG | 0-1000 |
| PCL-MB-1.5KG | 0-1500 |
| PCL-MB-2KG | 0-2000 |
| PCL-MB-2.5KG | 0-2500 |
| PCL-MB-3KG | 0-3000 |
| PCL-MB-5KG | 0-5000 |
| PCL-MB-6KG | 0-6000 |
| PCL-MB-7.5KG | 0-7500 |
| COMPOUND RANGES |
| PCL-MB-05BG | ±5 |
| PCL-MB-010BG | ±10 |
| PCL-MB-15V30BG | -15 to 30 |
| PCL-MB-15V60BG | -15 to 60 |
| VACUUM RANGES |
| PCL-MB-10VG | 0 to -5 |
| PCL-MB-10VG | 0 to -5 |
| PCL-MB-15VG | 0 to -15 |
|
| ABSOLUTE PRESSURE MODULES |
| MODEL NO. | RANGE (psia) |
| PCL-MB-005A | 0-5 |
| PCL-MB-010A | 0-10 |
| PCL-MB-015A | 0-15 |
| PCL-MB-020A | 0-20 |
| PCL-MB-030A | 0-30 |
| PCL-MB-050A | 0-50 |
| PCL-MB-100A | 0-100 |
| PCL-MB-250A | 0-250 |
| PCL-MB-300A | 0-300 |
| PCL-MB-500A | 0-500 |
| PCL-MB-1KA | 0-1000 |
| PCL-MB-1.5KA | 0-1500 |
| PCL-MB-2KA | 0-2000 |
| PCL-MB-2.5KA | 0-2500 |
| PCL-MB-3KA | 0-3000 |
| PCL-MB-5KA | 0-5000 |
| PCL-MB-6KA | 0-6000 |
| PCL-MB-7.5KA | 0-7500 |
|
| PLUG IN PRESSURE MODULES |
| UNIDIRECTIONAL |
| MODEL NO. | RANGE (InH2O) |
| PCL-MA-0.25WC | 0-0.25 |
| PCL-MA-0.5WC | 0-0.5 |
| PCL-MA-01WC | 0-1.0 |
| PCL-MA-02WC | 0-2.0 |
| PCL-MA-03WC | 0-3.0 |
| PCL-MA-05WC | 0-5.0 |
| PCL-MA-10WC | 0-10 |
| PCL-MA-15WC | 0-15 |
| PCL-MA-25WC | 0-25 |
| PCL-MA-50WC | 0-50 |
| PCL-MA-100WC | 0-100 |
| PCL-MA-150WC | 0-150 |
| PCL-MA-200WC | 0-200 |
| BIDIRECTIONAL |
| PCL-MA-0.125BWC | ± 0.125 |
| PCL-MA-0.25BWC | ± 0.25 |
| PCL-MA-0.5BWC | ± 0.5 |
| PCL-MA-01BWC | ± 1.0 |
| PCL-MA-1.5BWC | ± 1.5 |
| PCL-MA-2.5BWC | ± 2.5 |
| PCL-MA-05BWC | ± 5.0 |
| PCL-MA-7.5BWC | ± 7.5 |
| PCL-MA-12.5BWC | ±12.5 |
| PCL-MA-25BWC | ± 25 |
| PCL-MA-50BWC | ± 50 |
| PCL-MA-100BWC | ± 100 |
|
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: The above ordering table contains only a partial list of plug in modules available. For a complete listing please refer to the "Related Links" below.
Ordering Example: (1) PCL-1BR handheld pressure calibrator base unit with alarms and datalogging capability, $2,200.00, plus (1) PCL-MB-015G 0-15 psig plug in pressure module, $1,110.00, plus (1) PCL-MB-100G 0-100 psig plug in pressure module, $1,110.00, $2,200.00 + 1,110.00 + 1,110.00 = $4,420.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Related Products
|
 |
 |
 |
 |
 |
 |
|
Related Products
|
 |
PCL-M Series:
|
|
Plug-In Modules for PCL-1B and PCL-2A Calibrators
|
 |
 |
|
|
|
 |
 |
|
|