Sanitary RTD Sensor with Thermowell/ Removable Sensor/ Connection Head For Use in Clean-In-Place (CIP) Processes |
| PRS-TW-NB9W Series Sanitary RTD Sensors |
|
 |
|
|
|
|
$
195.00
PRS-3-100-A-TW-0250-D1-NB9W
|
| |
Clean-In-Place Design for Use in Food, Dairy and Pharmeceutical Processes
|
| |
Removable Probe Assembly is Spring Loaded Into Thermowell for Good Thermal Response
|
| |
Standard Mounting Cap is a 1½" 16AMP Tri-GripTM (Tri-Clamp® Compatible) Design, Other Cap Sizes and Styles are Available
|
| |
Avalable with 15⁄8, 2½:", 4½", 7½" and 10½" Immersion Lengths Standard
|
| |
White Polypropylene Screw Cap Connection Head Standard, Stainless Steel and Flip Top Polypropylene Heads Also Available
|
| |
Wetted Surfaces are 316L Stainless Steel with a Surface Finish of 32 microinches or Better
|
| |
4-Wire, Pt100 Class A Platinum RTD Sensor (100.00±0.06Ω at 0°C) Standard
|
| |
Process Measurement Temperature Range: -50 to 200°C (-50 to 392°F)
|
| |
Compatible with 3-Wire and 2-Wire RTD Instruments & Transmitters
|
View related products - Sensors and Transducers
|
| |
|
|
|
 |
This Pt100 RTD sensor is designed for use in sanitary or
Clean-In-Place (CIP) applications where the use of a
thermowell assembly is preferred over direct immersion sensors.
The thermowell includes a 1½", 16AMP cap feature for
easy installation using industry standard gaskets and clamps.
The spring loaded RTD probe can be removed from the
thermowell without exposing the system to ambient conditions for
calibration or replacement. This sensor is also supplied
with a white polypropylene screw-cap style connection head
with 3/4"NPT conduit connection standard, Stainless steel
screw-cap heads, and a flip top style white polypropylene
head are also available.
Sensor Specifications Include:
316L stainless steel process wetted surfaces with surface finishes
of 32 microinches or better.
Immersion lengths of 15⁄8, 2½", 4½", 7½,
and 10½" are available from stock, with others available.
Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting
the requirements of IEC 60751.
These sensors can be used with 2-wire or 3-wire systems see information below.
Insulation resistance: 100 megohms minimum at 100 VDC.
Optional stainless steel connection heads available.
These sensors are supplied standard as 4-wire assemblies with two
red wires and two white wires. When used in 3-wire applications,
cut off one white wire making sure that it will not contact any terminals
or metal surfaces (note: twisting the two white wires together will reduce
the lead wire resistance on one side of the sensing element by half
adversely affecting the accuracy of the reading).
When used in 2-wire applications, cut off one white wire
and one red wire (note: in 2-wire applications, twisting the two
same-colored wires together at the terminals will not adversely
affect your sensor accuracy since both wires will be affected by
the reduction in resistance).
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Notes: For other cap sizes and styles, for other lengths, or for thermistor or thermocouple versions of this product, please contact Sales.
Options: For a flip top polypropylene head, change "NB9W" in model number to "NB16W" and add $7 to the price, for a large stainless steel screw top head, change to "NB15" and add $37 to the price, for a medium sized stainless steel screw top head, change to "NB13" and add $55 to the price.
Ordering Example: (1) PRS-3-100-A-TW-0450-D1-NB9W Removable Pt100 RTD Sensor with 1½", 16AMP Cap, 15⁄8" Immersion Length Thermowell, Spring Loaded with a White Polypropylene Screw Cover Head = $215.00
|
|
 |
|
 |
|  |
|
Keywords.:Hygienic Sensors Sanitary Thermowell/ Removable Sensor/ Connection Head Assemblies for Clean-In-Place Sanitary Systems
|
Back to top
|
|
|