Sanitary RTD Sensors with Thermowell/ Removable Sensor/ M12 Connector for use in Clean-In-Place (CIP) Processes |
| PRS-TW-M12 Series Sanitary RTD Sensors |
|
 |
|
|
|
|
$
180.00
PRS-3-100-A-TW-0163-D1-M12
|
| |
Clean-In-Place Design for Use in Food, Dairy and Pharmaceutical Processes
|
| |
Standard Mounting Cap is a 1½" 16AMP Tri-GripTM (Tri-Clamp® Compatible) Design, Other Cap Sizes and Styles are Available
|
| |
Removable Probe Assembly is Spring Loaded Into the Thermowell for Good Thermal Response
|
| |
Available with Standard 15⁄8, 2½, 4½, 7½, and 10½" Thermowell Immersion Lengths, Other Lengths Available
|
| |
Sensor Includes 4-Wire M12 Connector Plug for Attachment to Process Instrumentation
|
| |
Wetted Surfaces are 316L Stainless Steel, Surface Finish = 32 Microinch or Better
|
| |
4-Wire, Pt100, Class A Platinum RTD Sensor (100.00 ±0.06 Ω at 0°C) Standard
|
| |
Process Measurement Temperature Range: -50 to 200°C (-58 to 392°F)
|
| |
Compatible with 3-Wire and 2-Wire RTD Instruments
|
View related products - Sensors and Transducers
|
| |
|
|
|
 |
This Pt100 RTD sensor is designed for use in sanitary or
Clean-In-Place (CIP) applications where the use of a
thermowell assembly is preferred over direct immersion sensors.
The thermowell includes a 1½", 16AMP cap feature for
easy installation using industry standard gaskets and clamps.
The spring loaded RTD probe can be removed from the
thermowell without exposing the system to ambient conditions for
calibration or replacement. This sensor includes a 4-Pin, M12 Connector
for easy installation using an extension cable.
Sensor Specifications Include:
316L stainless steel process wetted surfaces with surface finishes
of 32 microinches or better.
Immersion lengths of 15⁄8, 2½", 4½", 7½,
and 10½" are available from stock, with others available.
Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting
the requirements of IEC 60751.
These sensors can be used with 2-wire or 3-wire systems see information below.
Insulation resistance values of 100 megohms minimum at 100 VDC.
These sensors are supplied standard as 4-wire assemblies with
4-pin connectors. When used in 3-wire applications,
use pins A, B and C as shown in the wiring detail below.
When used in 2-wire systems, connect one wire to pins A or B, and the other wire to pins C or D as shown below.
| Wiring Diagram |
 |
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: For other cap sizes or styles, other immersion lengths, or for thermistor versions of this product, please contact Sales.
Ordering Example: (1) PRS-3-100-A-TW-0163-D1-M12 Removable 4-wire Pt100 RTD sensor (100 Ω at 0°C, Class A accuracy) spring loaded in a 1½" 16A Tri-Grip style thermowell with 15⁄8" immersion length and M12 connector = $180.00
|
|
 |
|
 |
|  |
|
Keywords.:Hygienic Sensors Sanitary Thermowell/ Removable Sensor/ M12 Connector Assemblies for Clean-In-Place Sanitary Systems
|