Wet/Wet Differential Pressure Transmitters |
| PX409 Series Wet/Wet Differential PressureTransducers and Transmitters |
|
 |
|
|
|
|
|
$
775.00
PX409-015DWUV
|
| |
FAST DELIVERY! Stock to 1-Week!
|
| |
Precision Micro-Machined Silicon Core
|
| |
5-Point NIST Traceable Calibration
|
| |
High Stability, Low Drift
|
| |
Welded Stainless Steel Construction
|
| |
316L SS Wetted Parts
|
| |
Now Available with M12 Connector, Order Model PX459 (See Part Number Builder at bottom of page)
|
| |
Premium Temperature Performance
|
| |
Broad Compensated Temperature Range
|
| |
Durable, 1 Million Cycle Life
|
| |
Ruggedized with Secondary Containment
|
| |
Customized Specifications Available
|
View related products - Pressure Transducers
|
| |
|
|
|
 |
Get all the great performance characteristics of the
Micro-Machined Silicon Transducers in these wet/wet
differential pressure models. These rugged stainless
steel transducers are ideal for tough industrial
automotive, or aerospace applications requiring a
wet/wet transducer. They can be used in test benches,
fitler monitoring, hydraulic, flow, or water/wastewater
applications, as well as factory or pneumatic air, pitot
tubes, air speed and other industrial or aerospace
applications. The solid state silicon core and all stainless
steel wetted parts will provide long, reliable service life
with excellent long term stability.
COMMON SPECIFICATIONS
Accuracy: 0.08% BSL linearity, hysteresis and repeatability combined
Minimum Resistance Between Transducer Body and Any Wire: 100 MΩ
Operating Temperature:
mV/V and 5 to 10 Vdc Output: -45 to 121°C (-49 to 250°F)
mA Output: -45 to 115°C (-49 to 239°F)
Compensated Temperature Range:
10 inH2O to 5 psi: -17 to 85°C (1 to 185°F)
15 to 1000 psi: -29 to 85°C (-20 to 185°F)
Thermal Accuracy: Zero Span
% Span Shift over compensated temperature range
10 inH20 to 5 psi: ±1.00% ±1.00%
15 to 1000 psi: ±0.50% ±0.50%
Pressure Cycles: 1 million minimum
Long Term Stability (1-Year): ±0.1% FS typical
Bandwidth: DC to 1 kHz typical
Response Time: <1 ms
CE Complient: Meets EN61326-1: 2006 for industrial locations
Shock: 50 g, 11 ms, half-sine, vertical and horizontal axis
Vibration: 5-2000-5 Hz 30 minute cycle, Curve L Mil-Spec 810 figure 514-2-2, horizontal and vertical axis
Wetted Parts: 316L stainless steel
Line/Static Pressure: 500 psi max applied to both sides simultaneously
Proof Pressure (Differential):
10 inH2O range = 10 times range
1 psi range = 6 times range
2.5 to 750 psi ranges = 4 times range
1000 psi range = 3 times range
Hi Side Containment Pressure (Differential):
Ranges 10 inH2O to 5 psi: to 1000 psi
Ranges 15 to 1000 psi: to 3000 psi
Pressure Ports: ¼NPT male
Electrical Terminations:
PX409: 2 m (6') cable
PX409C: 2 m (6') cable with ½ NPT conduit thread
PX419: Mini-DIN (mating connector included)
PX429: Twist-lock, mating connector (sold separately)
PX459: M12 Connector, mating connector (sold separately)
Mating Connector for PX429: PT06F10-6S
Weight: 200 g (7 oz) max
UNI-DIRECTIONAL mV/V SPECIFICATIONS
Output: 10 mV/V ratiometric
Supply Voltage: 5 to 10 Vdc
Current Draw: 5 mA @ 10 Vdc
Input Impedance: 1000 to 5000 Ω
Output Impedance: 5000 Ω ±10% typical
Zero Balance:
Ranges ≤ 1psi: ±1% typ (2% max)
Ranges > 1psi: ±0.5% typ (1% max)
Span Setting:
Ranges ≤ 1psi: ±1% typ (2% max)
Ranges > 1psi: ±0.5% typ (1% max)
UNI-DIRECTIONAL VOLTAGE OUTPUT SPECIFICATIONS
Output Voltage/Supply Voltage: 0 to 5 Vdc/ 10 to 30 Vdc; 0 to 10 Vdc/15 to 30 Vdc (change "5V" to "10V" in model number)
Current Draw: 10 mA max
Maximum Current Output: 2 mA (= 2500 Ω min load resistance)
Output Impedance: 100 Ω
Zero Balance:
Ranges > 1psi: ±0.5% typ (1% max)
Ranges ≤ 1psi: ±1% typ (2% max)
Span Setting:
Ranges > 1psi: ±0.5% typ (1% max)
Ranges ≤ 1psi: ±1% typ (2% max)
UNI-DIRECTIONAL mA SPECIFICATIONS
Output: 4 to 20 mA
Supply Voltage: 9 to 30 Vdc; [9 to 20 Vdc above 105°C (229°F)]
Max Loop Resistance: (Vs-9) x 50 Ω
Zero Balance:
Ranges > 1psi: ±0.5% typ (1% max)
Ranges ≤ 1psi: ±1% typ (2% max)
Span Setting:
Ranges > 1psi: ±0.5% typ (1% max)
Ranges ≤ 1psi: ±1% typ (2% max)
Four Termination Styles are available: PX409 = 2 m (6ft) cable
PX419 = mini-DIN connector PX429 = Twist-Lock connector PX459 = M12 connector
 |
 Still can't find the right model? Specify the perfect transducer for your application with this easy, step-by-step configurator. |
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: To order models with different electrical terminations, change model number to on of the following: PX409 = Cable Connection (featured in chart above) PX419 = mini-DIN Connection (mating connector provided) PX429 = Twist Lock Connector (mating connector sold separately) Additional Ranges Available See Part Number Builder (below) for the full selection of pressure ranges
Ordering Example: (1) PX429-005DWU5V Wet/Wet 5 psi diff. pres. range, 0 to 5 Vdc output, twist-lock termination, $840.00, plus (1) PT06F10-6S Mating twist-lock connector (sold separately), $26.50, $840.00 + 26.50 = $866.50
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Electrical Termination
|
| |
Select PX409 for 2 m (6') cable PX419 for mini-DIN PX429 for Twist-Lock (mating connector sold separately) PX459 for M12 Connector (mating connector sold separately)
|
(2)
|
Pressure Range (PSI)
|
| |
Select 10W for 0-10 inH2O 001 for 1 psi 2.5 for 2.5 psi 005 for 0-5 psi 015 for 0-15 psi 030 for 0-30 psi 050 for 0-50 psi 100 for 0-100 psi 150 for 0-150 psi 250 for 0-250 psi 500 for 0-500 psi 750 for 0-750 psi 1.0K for 0-1000 psi
|
(3)
|
Units
|
| |
Select DWU for Wet/Wet Differential Pressure DDU for Wet/Dry Differential Pressure
|
(4)
|
Output
|
| |
Select V for 10 mV/V Output 5V for 0-5 Volt dc Output 10V for 0-10 Volt dc Output I for 4-20 mA Output
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
 |
|
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |