Paperless Recorder |
| RD-MV100 |
|
 |
|
|
|
|
|
|
|
| |
Up to 12 Channels on RD-MV100
|
| |
Up to 30 Channels on RD-MV200
|
| |
Programmable Inputs: Thermocouple, RTD, Voltage
|
| |
TFT Color LCD for Better Viewing
|
| |
Removable Storage on 3.5" Floppy Disk, Zip Disk, or PCMCIA ATA Flash Memory Card
|
| |
Data Collection Over Ethernet Network (Standard)
|
| |
Network-Compatible Sophisticated Software
|
| |
Highly Reliable Hardware
|
View related products - Recorders
|
| |
|
|
|
 |
Features
5.5-inch LCD color display, wide-viewing-angle
(RD-MV100)
10.4 inch LCD color display, wide-viewing-angle
(RD-MV200)
Status display area
Graphically displays the operating status of the
RD-MV100/RD-MV200
Trend display area
(simultaneous display of all channels possible)
Displays the scale values and engineering unit for
each channel and arbitrary messages, along with
the waveforms. The orientation (vertical/
horizontal) of the trend display and background
color (white/black) can be switched. The fastest
trend display update rate is 15 sec/div
(approximately 2376 mm/h in terms of display
speed) for a 125-ms measurement interval model.
Digital display area
Displays channels/tag numbers, engineering units,
and each channel's alarm status, as well as the
measurement values. The fastest display update
interval is 1 second.
Reliable Data Storage in Internal Reliable Data Storage in Internal Memory
The RD-MV100/200 saves measurement data in internal memory. Data in internal memory can also be transferred to
PCs or data servers either online or using a removable storage medium. The measurement data memory consists of
nonvolatile flash memory (1.2 MB) that does not require battery backup. This means data written to memory will not be
lost due to events such as a power outage.
Simultaneous Extended-Period Data Storage and Detailed Analysis Simultaneous Extended-Period Data Storage and Detailed Analysis
Display
data. for extended-period trend recording
The display data format is used to save data displayed as waveforms.
Each time the waveform display is updated, two data values
(maximum and minimum values) measured since the previous update
are saved.
Event data. for detailed analysis
The event data format is used to save all data in a specified data
saving interval. Event data can be used in combination with the trigger
functions to detect and analyze abnormal data. A pretrigger can also
be set, making it possible to analyze data before and after the trigger.
Removable storage drive
Choose from a floppy disk drive, Zip drive, or
PCMCIA ATA flash memory card slot.
Network Communication Options
Ethernet (10BASE-T),
RS-232 or RS-422-A/485
The RD-MV100/RD-MV200 can easily
be connected directly to a PC, even
without using general communication
protocols such as GP-IB and RS-232-C.
Use a cross Ethernet cable for a
one-to-one connection.
Optional Alarm output and remote
control
Input modules
DC voltage, TC, RTD and
digital inputs (can be mixed).
Clamp or screw terminals
can be selected
| Input |
Range/Type |
Measuring
range |
Measurement accuracy (digital display) |
Digital display maximum resolution |
| DCV |
20mV |
-20.00 to 20.00 mV |
±(0.1% of rdg + 2 digits) |
10 µV |
| 60mV |
-60.00 to 60.00 mV |
10 µV |
| 200mV |
-200.00 to 200.00 mV |
100 µV |
| 2V |
-2.000 to 2.000 V |
1 mV |
| 6V |
-6.000 to 6.000 V |
1 mV |
| 20V |
-20.00 to 20.00 V |
10 mV |
| TC |
R |
0.0 to 1760.0°C |
32 to 3200°F |
±(0.15% of rdg + 1°C)
R, S: 0 to 100°C, ±3.7°C;
100 to 300°C, ±1.5°C B: 400 to
600°C, ±2°C; if less than 400°C,
accuracy is not guaranteed. |
0.1°C |
| S |
0.0 to 1760.0°C |
32 to 3200°F |
| B |
0.0 to 1820.0°C |
32 to 3200°F |
| K |
200.0 to 1370.0°C |
-328 to 2498°F |
±(0.15% of rdg + 0.7°C)
If -200 to -100°C, then
±(0.15% of rdg + 1°C)
|
| E |
-200.0 to 800.0°C |
-328.0 to 1472.0°F |
±(0.15% of rdg + 0.5°C)
|
| J |
200.0 to 1100.0°C |
-328.0 to 2012.0°F |
±(0.15% of rdg + 0.5°C) If -200 to -100°C, then ±(0.15% of rdg + 0.7°C)
|
| T |
-200.0 to 400.0°C |
-328.0 to 752.0°F |
| N |
0.0 to 1300.0°C |
32 to 2372°F |
±(0.15% of rdg + 0.7°C)
|
| C |
0.0 to 2315.0°C |
-328.0 to 4199°F |
±(0.15% of rdg + 1°C)
|
| L |
-200.0 to 900.0°C |
-328.0 to 1652.0°F |
±(0.15% of rdg + 0.5°C) If -200 to -100°C then ±(0.15% of rdg + 0.7°C)
|
| U |
-200.0 to 400.0°C |
-328.0 to 752.0°F |
| RTD |
Pt100 |
-200.0 to 600.0°C |
±(0.15% of rdg + 0.3°C)
|
| JPt100 |
-200.0 to 550.0°C |
| DI |
Voltage Input |
OFF: Less than 2.4 V ON: 2.4 V or greater |
|
|
| Contact inputt |
Contact ON/OFF |
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Standard units include floppy disk storage, 120/240 Vac power, 3-pin power inlet with UL/CSA cable, clamp input terminals, and complete operator’s manual. To order Zip disk or ATA flash card change the “-1” to “-2” or “-3” respectively and add $166. To order with 12 Vdc power input (includes AC adaptor), add suffix “-2” to model number and add $386. To order with different power cord add suffix “-F” for VDE, “-R” for SAA, or “-S” for BS cable to model number. No additional cost. (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Manual
|
 |
 |
 |
 |
 |
 |
|
Product Manual
|
|
Download
RD-MV200 - RD-MV200 Series Recorder User Manual
|
|
Download
RD-MV100/200 - RD-MV100/200 Communications Interface Manual
|
|
Download
RD-MV100 - RD-MV100 Series Recorder User Manual
|
|
|
 |
 |
|
|