Field Adjustable Screw Plug Immersion Heater
Clean Water & Oil Applications |
| VTS Series |
|
 |
|
|
|
|
|
$
975.00
VTS-3180/240
|
| |
2½" NPT Steel Screw Plug
|
| |
Incoloy® Sheath Elements
|
| |
Field Adjustable kW and Voltage Ratings
|
| |
Integral Thermocouple. Type J
|
| |
General Purpose Terminal Enclosure
|
| |
Process Temperature up to 148°C (300°F)
|
View related products - Immersion Heaters
|
| |
|
|
|
 |
Omegalux® field adjustable screw
plug immersion heaters can be
applied to a variety of clean water
and oil applications. The unique
versatility of this design allows field
adjustment of the rating by simple
connections to the six elements of
the heater. This simplifies selection
and spare parts since each heater
may be used in several different
heating applications. See the
application matrix for the many
kW values available with different
wiring styles and voltages.
SPECIFICATIONS
Wattage: 0.5 to 40 kW - Water; 0.5 to 10 kW - Oil
Watt Density:
2 to 80 W/In2 - Water; 2 to 23 W/In2- Oil
Power:
1 Phase: 120, 208, 240 and 480V
3 Phase: 208, 240 and 480V
Sheath: .430" diameter Incoloy
Screw Plug: 2½" Steel
Enclosure: General purpose, NEMA-1 rated enclosure can be rotated 360° to match conduit connections
Selection Example: Light oil heating application, 2.75 kW 240V 3-phase capacity- Select oil application matrix
- Locate 2.75 kW on chart. Use 3 kW as next higher rating. Confirm that 20 w/sq. in. is suitable for light oil.
- Find column with 240 Volt 3-phase power
- Intersection of row and column is model number VTS-3240/480. Confirm 3-phase and single-phase available. Note there is spare capacity for back up or for future increase in requirements.
- Locate model number VTS-3240/480 in the "To Order" table for price. When received, this heater will have instructions on wiring for the required rating. Contact Omega’s Application Engineers with any questions.
Application Matrix—Oil
| Model No. |
| kW | W/In2 | 120 Volts 1 phase | 208 Volts 1 or 3 phase | 240 Volts 1 or 3 phase | 480 Volts 1 or 3 phase |
| 0.50 | 2 | | | VTS-3240/480 | |
| 0.75 | 5 | VTS-3240/480* | VTS-3240/480* | | |
| 1.50 | 5 | VTS-3240/480 | VTS-3240/480 | VTS-3240/480 | VTS-3180/480 |
| 2.25 | 15 | | VTS-3240/480* | VTS-3180/480* | |
| 2.50 | 6 | VTS-3400/480 | VTS-3400/480 | VTS-3400/480 | |
| 3.00 | 20 | VTS-3240/240* | VTS-3240/240* | VTS-3240/480* | |
| 4.50 | 15 | VTS-3180/240 | VTS-3240/480 | VTS-3180/480 | VTS-3180/480 |
| 5.00 | 11 | VTS-3200/240 | VTS-3200/240 | VTS-3200/240 | |
| 6.00 | 20 | VTS-3240/240 | VTS-3240/240 | VTS-3240/480 | VTS-3240/480 |
| 10.00 | 21 | | | VTS-3400/480 | VTS-3400/480 |
Application Matrix—Water
| Model No. |
| kW | W/In2 | 120 Volts 1 phase | 208 Volts 1 or 3 phase | 240 Volts 1 or 3 phase | 480 Volts 1 or 3 phase |
| 0.50 | 2 | | | VTS-3240/480 | |
| 0.75 | 5 | VTS-3240/480* | VTS-3240/480* | | |
| 1.50 | 5 | VTS-3240/480 | VTS-3240/480 | VTS-3240/480 | VTS-3180/480 |
| 2.25 | 15 | | VTS-3240/480* | VTS-3180/480* | |
| 2.50 | 6 | VTS-3400/480 | VTS-3400/480 | VTS-3400/480 | |
| 3.00 | 20 | VTS-3240/240* | VTS-3240/240* | VTS-3240/480* | |
| 4.50 | 15 | VTS-3180/240 | VTS-3240/480 | VTS-3180/480 | VTS-3180/480 |
| 5.00 | 11 | VTS-3200/240 | VTS-3200/240 | VTS-3200/240 | |
| 6.00 | 20 | VTS-3240/240 | VTS-3240/240 | VTS-3240/480 | VTS-3240/480 |
| 9.00 | 59 | | | VTS-3180/240* | VTS-3180/480* |
| 10.00 | 21 | | | VTS-3400/480 | VTS-3400/480 |
| 12.00 | 78 | | | VTS-3240/240* | VTS-3240/480* |
| 18.00 | 59 | | | VTS-3180/240 | VTS-3180/480 |
| 20.00 | 80 | | | VTS-3200/240 | VTS-3400/480* |
| 24.00 | 78 | | | VTS-3240/240 | VTS-3240/480 |
| 40.00 | 80 | | | | VTS-3400/480 |
Note: Shaded items are 3 phase only; *Items have 100% spare capacity
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: 240 and 480 in model number indicates max voltage rating. Other voltages can be used. See application matrix for details.
Ordering Example: (1) VTS-3180/480 Field adjustable heater with 480 Vac maximum, $975.00
|
|
 |
|
 |
|
 |
|
Back to top
|