Wireless DIN Rail Monitor & Controller |
| wiDR Series |
|
 |
|
Wireless DIN Rail Monitor & Controller
 |
| Click for larger image. |
|
|
|
|
|
|
 |
wiSeries Wireless DIN Rail Monitoring
and Control Device
The new OMEGA wiSeries DIN Rail wireless monitoring and
control device is compatible with a large and growing number
of OMEGA wireless sensors:
UWTC "Universal Wireless Thermocouple" Type J, K, T, E,
R, S, B, N, and C.
UWRTD "Universal Wireless RTD".
zSeries wireless End Devices with sensors for Temperature,
Humidity & Barometric Pressure (coming soon).
The wiSeries wiDR DIN Rail Monitor and Controller can
monitor up to eight (8) wireless sensors.
The compact instrument connects directly to an Ethernet
network and the Internet and features OMEGA’s awardwinning
embedded Web Server. It is easily configured and
monitored with a Web browser over the Ethernet network or
the Internet.
Alternatively, the wiDR DIN Rail Monitor & Controller can
instead be connected to the USB port of a single computer
with a "USB Ethernet Adaptor" that are inexpensive and widely
available.
MONITOR AND ALARM
The wiDR meter-controller comes standard with a choice of either
two Form C relays, or two SSR’s (solid state relays) that can be
used for control functions or alarms. The wiDR meter can monitor alarm conditions for any or all of the wireless sensors.
For example, the wiDR meter can be set up to trip an
alarm if any one of the sensors indicated it was above
or below a pre-set alarm point.
MONITOR AND CONTROL LOCALLY AND OVER
THE INTERNET
The new OMEGA® wiSeries wireless monitoring and
control system provides local monitoring and control,
along with remote Web-based monitoring of
temperature from thermocouples, RTD’s, and
semiconductor sensors, as well as humidity, and
barometric pressure.
The wireless sensors transmit up to 300' (approx
90 meters-without obstructions or interference) to a
wiSeries monitor-controller connected directly to an
Ethernet network and the Internet. The wireless
system complies with IEEE 802.15.4 operating at
2.4 GHz.
The OMEGA wiSeries system let’s you monitor and
record temperature, relative humidity, and barometric
pressure over an Ethernet network or the Internet
without any special software-just your Web Browser.
WIRELESS SENSORS
OMEGA offers a wide and growing selection of wireless
sensors for a variety of applications. Depending on
application, the wireless sensors are powered by 2
"AA" batteries, a single lithium battery (approx "AA"
size), or an external AC Adaptor that operates on any
voltage worldwide from 100 to 240 Vac.
Wireless sensors are available with external probes
appropriate for an almost unlimited variety of industrial
and commercial applications.
ETHERNET
The wiDR monitor-controller is an independent node
on the network sending and receiving data in standard
TCP/IP packets. It is easily configured from a Web
Browser and can be password protected. From within
an Ethernet LAN or over the Internet, the user simply
types the IP address (such as 192.168.1.200) or an
easy to remember name (such as "Oven 5" or
"Chicago Test Fixture") and the wiSeries meter serves
a Web Page with the current readings.
ALARM AND EMAIL
The wiDR monitor-controller can trigger an alarm if
variables go above or below a set point that you determine. Your alarm can be sent by email to a single
user or to a group distribution list, including text
messages to Internet enabled cell phones and PDA’s.
The OMEGA "Mail Notifier" software is a free and easy
program for this application.
The wiDR monitor-controllers operate on any AC
voltage worldwide from 100 to 240 Vac and 50 to
60Hz. The monitor-controller connects directly to an
Ethernet Network or the Internet. Unlike an RS232 or
USB device, it does not require a host computer.
EMBEDDED WEBSERVER
The OMEGA wiSeries wireless sensor system is easy
to install, simple to operate, and features OMEGA’s
award-winning iServer technology with an Embedded
Web Server that requires no special software.
CHARTS AND GRAPHS
The OMEGA wiDR monitor serves Active Web Pages
to display real time readings and charts of
temperature, humidity, and barometric pressure. You
can also log data in standard data formats for use in a
spreadsheet or data acquisition program such as Excel
or Visual Basic. OMEGA offers a free and easy to use
program for logging data to Excel.
The virtual chart viewed on the web page is a JAVA
Applet that records a chart over the LAN or Internet in
real time. With the OMEGA wiSeries system there is
no need to invest time and money learning a
proprietary software program to log or chart the data.
Chart scales are fully adjustable on the fly. For
example, the chart can display one minute, one hour,
one day, one week, one month or one year.
Temperature and humidity can be charted across the
full span (-40 to 125°C, and 0 to 100% RH) or within
any narrow range such as (20 to 30°C).
SPECIFICATIONS
Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3A (resistive load); configurable for ON/OFF
Output 1: SPDT type, can be configured as Alarm 1 output
Output 2: SPDT type, can be configured as Alarm 2 output
SSR: 20 to 265 Vac @ 0.05 to 0.5A (resistive load); continuous
DC Pulse: Non-Isolated; 10 Vdc @ 20 mA
Alarm 1 & 2 (programmable)
Type: Same as Output 1 and 2
Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
Analog Output (programmable): Non-Isolated, Retransmission 0 to 10Vdc or 0 to 20mA, 500Ω max (Output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analog Out is not scaled below 3% of Output FS.
Network and Communications
Ethernet: Standards Compliance IEEE 802.3 10Base-T
Supported Protocols: TCP/IP, ARP, HTTPGET
LED Indicators: Network Activity, Network Link, Diagnostics, Receive & Power
Management: Device configuration and monitoring through embedded WebServer
Embedded WEB Server: Serves WEB pages ( JAVA™ Applets) containing real-time data and live updated charts within definable time intervals.
Software: The software packages available for the wiSeries wireless system are iConnect (configuration software for the Ethernet interface), iLog (Excel-based software for automatic data logging), and Mail Notifier (email alarm notification software).
Wireless Communication
Standard: IEEE 802.15.4
Frequency: 2.4 GHz (2410MHz), Channel #12
Network Topology: Star Topology
Range:
UWTC-1, UWRTD-1: up to 60 m (200 ft) without obstructions or interference.
UWTC-2, UWRTD-2: up to 120 m (400 ft) without obstructions or interference.
zED-*: up to 91 m (300 ft) without obstructions or interference.
zED-*-P: up to 1000 m (3280 ft) without obstructions or interference.
General
Connection: Screw terminals
Dimensions: 93 H x 39 W x 125 mm D (3.64 x 1.55 x 4.93")
Operating Temp: 0 to 55°C (32 to 131°F), 90% RH non-condensing
Line Voltage/Power: 90 to 240 Vac ±10%, 50 to 400 Hz*, 110 to 375 Vdc, equivalent voltage
*No CE compliance above 60 Hz
Low Voltage/Power Option: 24 Vac**, 12 to 36 Vdc. External power source must meet Safety Agency Approvals
** Units can be powered safely with 24Vac power, but no certification for CE are claimed
|
| |
 |
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Other outputs options are available, please contact our Engineering Department.
Ordering Example: (1) wiDR33-U Wireless meter/controller for UWTC with 2 relays = $395.00
|
|
 |
|
 |
|  |
|
Keywords.:Wireless DIN Rail Monitor & Controller
|
Back to top
|
|
|