Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Omega.com - Your One-Stop Source for Process, Measurement and Control! (888) TCOMEGA (in US/Canada) or (203) 359- 1660 (for international)
Navigation Image Map  
search
      
 

Benchtop Oscilloscope

BOS Series   
1 year warranty NEW! CE
 
Oscilloscope
BOS Series:Benchtop Oscilloscope
Click for larger image.
   
$ 499.00  BOS-200
20 to 60 MHz Dual Trace, ALT Trigger
Vertical Sensitivity: 1 mV/DIV
Horizontal Resolution: 10 nS
Hold-Off, X-Y Operation, Z-Mod, Y-Output
23 Calibrated Ranges, Main Time Base

View related products - Process Measurement and Control Instruments

Click to scroll below to order See Specs PDF View a printer friendly page

The BOS Series comprises dual-channel oscilloscopes with frequency bandwidths of 40 to 100 MHz at -3 dB, a maximum sweep of 10 ns, a maximum sensitivity of 1 mV/DIV, and 150 mm rectangular CRT with internal graticule.
These oscilloscopes are rugged, easy to operate, and highly reliable. They are ideal for research, production, and electronics applications. The BOS converts a high-input differential voltage (≤1300 Vp) into a low voltage (≤6.5V).
Optional accessories include differential voltage probes, which provide a safe means of measuring a floating potential.

Models BOS-200 BOS-205 BOS-350 BOS-355 BOS-605
Cathode Ray Tube 6" diagonal, rectangular screen with internal graticule 8 x 10 DIV (1 DIV = 1 cm), B31 phosphor, 2 kV acceleration voltage 6" diagonal, rectangular screen with internal graticule 8 x 10 DIV (1 DIV = 1 cm), B31 phosphor, 12 kV accel voltage
Vertical Deflection
Bandwidth DC to 20 MHz (-3 dB) DC to 40 MHz (-3 dB) DC to 60 MHz (-3 dB)
Sensitivity 1 mV/DIV to 1 V/DIV (5 MHz, -3 dB), x5 gain selected 5 mV/DIV to 5 V/DIV 1 mV/DIV to 1 V/DIV (10 MHz, -3 dB), x5 gain selected 5 mV/DIV to 5 V/DIV 1 mV/DIV to 1 V/DIV (15 MHz, -3 dB), x5 gain selected 5 mV/DIV to 5 V/DIV
Attenuator 1-2-5 sequence, 10 step with variable control
Input Impedance 1 MΩ ±2%, 25 pF ± 10%
Max Input Voltage 400 V (DC + AC peak)
Rise Time About 17.5 ns About 8.8 ns About 5.8 ns
Overshoot Less than 5%
Operation Mode CH 1, CH2, DUAL (ALT, CHOP)
Algebraic Addition CH 1 + CH 2, CH 1 - CH 2
Inverter CH 2 Only
Horizontal Deflection
X-Y Mode Switch slectable using X-Y switch; CH 1: X axis, CH 2: Y axis
Accuracy X Axis: ±6%, Y Axis: ±3%
Bandwidth DC to 1 MHz (-3 dB)
X-Y Phase Difference Approx. 3 degrees at 50 kHz
Sweep System
Sweep Display Mode Main, Mix Main, Mix, Delay Main, Mix Main, Mix, Delay Main, Mix, Delay
Hold-Off Time 5:1 continuously variable
Main Sweep
Sweep Speed 0.1 ?s/DIV to 2.0 s/DIV in 1-2-5 sequence, 23 steps
Accuracy ±3%
Variable Time Control 5:1, uncalibrated, continuously variable between steps
Sweep Magnification 10x, ±10%, extended sweep speed up to 10 ns/DIV
Delay Sweep
Sweep Speed 0.1 ?s/DIV to 2.0 s/DIV in 1-2-5 sequence, 23 steps 0.1 ?s/DIV to 2.0 s/DIV in 1-2-5 sequence, 23 steps
Accuracy ±3% ±3%
Sweep Magnification 10x, ±10%, extended sweep speed up to 10 ns/DIV 10x, ± 10%, extended sweep speed up to 10 ns/DIV
Delay Timeposition Variable control to locate desirable waveform for extending Variable control to locate desirable waveform for extending
Triggering
Trigger Coupling AUTO, NORM TV-V, TV-H AUTO, NORM TV-V, TV-H
Trigger Source CH 1, CH 2, ALT, LINE, EXT CH 1, CH 2, ALT, LINE, EXT
Slope ± ±
Trigger Sensitivity
Coupling TV-V, TV-H, Auto, Nom
Bandwidth DC to 1 kHz, 1 kHz to 100 kHz , 100 Hz to 20 MHz, 100 Hz to 20 MHz
Interior 1.0 DIV, 1.5 DIV, 1.0 DIV, 0.5 Vp-p
Exterior 0.5 Vp-p
Dimensions 324 W x 398 D x 132 mm H (12.75 x 15.67 x 5.20")
Net Weight Approx. 7.6 kg (16.75 lb)
Rated Range of Use 10 to 35°C (50 to 95°F), 10 to 80% RH
Component Test
Test Voltage Max 6 Vrms (open circuit) Max 6 Vrms (open circuit)
Test Current Max 11 mA (shorted) Max 11 mA (shorted)
Test Frequency Line frequency Line frequency
Components Capacitor, inductor, diode, transistor, zener, etc. Capacitor, inductor, diode, transistor, zener, etc.
CH 2 Output
Output level 100 mV (no load), 50 mV/DIV (with 50 Ω load)
Bandwidth 20 Hz to 20 MHz 20 Hz to 40 MHz 20 Hz to 60 MHz
Graticule Illumination Adjustable
Calibrator Square wave about 1 kHz, 2 V p-p ±3%Square wave about 1 kHz, 2V p-p ±3%
Z-Modulation Positive TTL signal, low-level blank intensity at any intensity, high-level unblank any intensityPositive TTL signal, low-level blank intensity at any intensity, high-level unblank any intensity
Trace Rotation Adjustable on front panel Adjustable on front panel
Power Source 110 to 130V (800 mA fuse), 200 to 260V (600 mA fuse) 50/60 Hz selectable
Power Consumption Approx. 38 W
Limits of Operation 0 to 50°C (32 to 122°F), 10 to 80% RH
Storage Environment -30 to 70°C (-22 to 158°F), 10 to 90% RH


 
 MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)    
 Part Number   Availability   Price   Description    Qty.
 BOS-200 12 Weeks   $499.00    20 MHz analog oscilloscope  
 BOS-205 In Stock   $800.00    20 MHz with delay sweep  
 BOS-350 In Stock   $790.00    40 MHz analog oscilloscope  
 BOS-355 12 Weeks   $825.00    40 MHz with delay sweep  
 BOS-605 8 Weeks   $1,270.00    60 MHz with delay sweep  
 Accessories
 BOSP-260 12 Weeks   $30.00    Oscilloscope probe for 60 MHz bandwidth x1, x10  
 BOSP-9100 In Stock   $54.00    Oscilloscope probe for 100 MHz bandwidth x1, x10  
All dollar amounts on this site are shown in US currency.

 Note: Comes with power cord, 110V fuse, 220V fuse, plastic screwdriver, 2 probes.
 Ordering Example: (1) BOS-200 20 MHz analog oscilloscope, $499.00

   
Keywords:Benchtop Oscilloscope, dissolved oxygen electrode usb daq board usb daq card water flow sensors

   Back to topBack to top

© Copyright 2003-2013  |  OMEGA ENGINEERING, Inc.
OMEGA
Privacy Statement  |  Terms and Conditions
   MXV MMV | 71