The FCLTX series free chlorine sensors feature amperometric measurement technology. They are designed for use in water treatment disinfection
applications and for use with chlorine dioxide or chlorine
generators, pools, etc. The sensors are available in several ranges
for detecting ppm levels of free chlorine. Choose the FCLTX-102 for 0 to 2 ppm, FCLTX-105 for 0 to 5 ppm or FCLTX-110 for 0 to 10 ppm of free chlorine. Membrane caps and fill solution are easily replaced to maximize sensor life. Sensors can be used in new installations with Omega flow cell or installed as
replacement for other 4 to 20 mA output free chlorine (FCl) sensors.
SPECIFICATIONS Measuring Range: FCLTX: 0 to 2, 0 to 5, or 0 to 10 ppm free chlorine pH Range: FCLTX: 5.5 to 9 Cross Sensitivity: FCLTX: Bromine, ozone and ClO2 (chlorine dioxide) Body Material: PVC Temperature Range: 0 to 45°C (32 to 113°F) Temperature Compensation: Integrated Maximum Pressure: 1 Bar (14.7 psig) Cable Length: 3 m (10') 2 conductors Flow Cell Process Connection: 1.4 FNPT inlet and outlet Output: 4 to 20 mA Flow Range: Minimum: 45 l/hr (0.2 gpm) Maximum: 135 l/hr (0.6 gpm) Supply Voltage: 12 to 24 Vdc, 250 mA min Chemical Compatibility: Up to 50% ethanol/water, up to 50% glycerol/water
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with instruction sheet.
Ordering Example: (1) FCLTX-105 Free Chlorine sensor with 4 to 20 mA output for 0 to 1 ppm, $1,015.00, plus (1) FC72 Flow cell, $295.00, plus (1) DPi32 1/32 DIN panel indicator, $159.00, $1,015.00 + 295.00 + 159.00 = $1,469.00