The CN2516 Series is part of
a range of new generation of
limit controllers that incorporate
numerous product specification,
communication, display interface
and software improvements that
surpass competitive limit device
offerings in ease of use and
programming. By adding more
versatile features and user-friendly
functionality like digital inputs, an
easy-to-use HMI, jumperless and
auto-hardware configuration,
24 Vdc transmitter power
supply and MODBUS®
communicationacross the
range, the CN2516 limit
controllertransform the
complicated into the simple
while saving you time (as much
as 50% on product set-up),
reducing inventory stock and
virtually eliminating the likelihood
of operator errors. The CN2516
limit controllers are affordable,
well-featured, easy to use and
adaptable with performance
features that work for you to make
limit control simple. The CN2516
is a fail-safe protection device to
prevent damage toequipment or
products. It will shut down process
when a preset temperature is
reached and cannot be reset by
the operator until the process has
returned to a safe condition.
Specifications Environmental Characteristics Operating Temp: 0° to 55°C (32° to 131°F) Storage Temp: -20° to 80°C (-4° to 176°F) Humidity: 20 to 95% non-condensing RH Electrical Supply Voltage: 100 to 240 V, 50/60 Hz, optional 20 to 48 Vac 50/60 Hz or 22 to 65 Vdc Power Consumption: 5 W/7.5 VA maximum Inputs Thermocouples: J, T, K, L, N, B, R, S, C; Pt Rh 20% vs. Pt 40% Rh RTD: 3-wire, PT100 DC linear (scalable -1999 to +9999) Volts: 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V DC Milliamps: 0 to 20 mA or 4 to 20 mA DC Millivolts: 0 to 50mV, 10 to 50mV Outputs Output 1: (Limit relay) fixed; outputs Output 2 and 3: (Alarm relay) are user-selectable and customized based on desired application; choose from the following output types Maximum # of Outputs: 3 for alarm, 24 Vdc transmitter power supply or retransmit of process value/limit trip setpoint Limit Relay: SPDT; 240 Vac 5 A resistive; lifetime >100,000 operations at rated voltage/current Alarm Relay: Optional SPDT; 240 Vac 2 A resistive; lifetime >500,000 operations at rated voltage/current SSR Drive: Optional Drive Capability: >10 Vdc nominal into 500 Ω minimum DC Linear: Optional 0 to 20 mA, 4 to 20 mA into 500 Ω max; 0 to 10V, 1 to 5V, 2 to 10V, 0 to 5V into 500 Ω min; outputs have 2% over/under drive applied; accuracy ±0.25% (mA into 250 Ω load, V into 2k Ω load); degrading linearity to ±0.5% for increasing burden to specified limits Triac: Optional 0.01 to 1 A AC, 20 to 280 Vrms, 47 to 63 Hz (limit 2) Transmitter Power Supply: Optional 24 Vdc (limit 1) Output Functions Process Alarm: (Reverse or direct) modes (alarm 1 and 2): high/low, band, deviation, logical OR/AND Retransmit: Process value or limit setpoint Electrical Performance Accuracy: ± 0.1% of input range ±1 LSD (thermocouple CJC better than 1°C) Input Sample Rate: 4 per second, 14-bitresolution Impedance: >10M Ω for the thermocouple and mV ranges, 47 kΩ for V ranges and 5 Ω for mA ranges Sensor Break Detection: <2 seconds (except zero based DC ranges), limit output opens, low alarms activate for RTD, mA or V ranges Communications Interface User-Selectable: 2-wire, RS485 serial communications option with choice of MODBUS RTU or ASCIIprotocol; 1200 to 19200 baud PC Configuration: Offline configuration from serial port to dedicated configuration socket (comms option not required) Protection IEC IP66 (NEMA 4X) front panel IEC IP20 (behind the panel protection) Dimensions Panel Cutout: 45 x 45 mm (1.77 x 1.77") Height: 48 mm (1.89") Width: (48 mm (1.89") Depth: 110 mm (4.33") Weight: 0.21 kg (0.46 lb) Mounting: Plug in panel with fixing strap
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with mounting bracket and operator's manual.
Keywords:1/16 DIN Temperature/Process Limit Controllers