High Temperature, Low Mass, Vacuum Formed Ceramic Radiant Full Cylinder Heaters |
| CRFC Series |
|
 |
|
|
|
|
|
$
159.00
CRFC-756/60-A
|
| |
Rated to 1800°F (982°C)
|
| |
Fast Heat-Up and Cool Down
|
| |
Greater Temperature Uniformity
|
| |
Lower Operating Costs
|
| |
Heating Element and Insulation in One
|
| |
Tube Furnaces
|
| |
Annealing Ovens
|
| |
Pipe Heating
|
View related products - Radiant Heaters
|
| |
|
|
|
 |
OMEGALUX® CRFC and CRWS Series radiant heaters are produced using high quality and purity
vacuum formed ceramic fiber, with low sodium inorganic bond. Helically
wound iron-chrome-aluminum wire elements assure top quality in this
extra-efficient, low watt density series. The helically wound wire is
imbedded into the vacuum formed ceramic fiber.
CRFC Series Full Cylinder Heaters

| Watts |
Volts |
Dimensions in cm (") |
Without Vestibules Model No. |
With Vestibules Model No. |
| A DIM |
B DIM |
C DIM |
D DIM |
| 220 | 60 | 15 (6) | 8 (3) | 2 (0.75) | 0.6 (0.25) | CRFC-756/60-A | CRFC-756/60-C-A |
| 440 | 120 | 30 (12) | 8 (3) | 2 (0.75) | 0.6 (0.25) | CRFC-7512/120-A | CRFC-7512/120-C-A |
| 250 | 60 | 15 (6) | 8 (3) | 3 (1) | 1 (0.5) | CRFC-16/60-A | CRFC-16/60-C-A |
| 500 | 120 | 30 (12) | 8 (3) | 3 (1) | 1 (0.5) | CRFC-112/120-A | CRFC-112/120-C-A |
| 300 | 60 | 15 (6) | 8 (3) | 3 (1.25) | 2 (0.75) | CRFC-1256/60-A | CRFC-1256/60-C-A |
| 600 | 120 | 30 (12) | 8 (3) | 3 (1.25) | 2 (0.75) | CRFC-12512/120-A | CRFC-12512/120-C- |
| 350 | 60 | 15 (6) | 9 (3.5) | 4 (1.5) | 3 (1) | CRFC-156/60-A | CRFC-156/60-C-A |
| 650 | 120 | 30 (12) | 9 (3.5) | 4 (1.5) | 3 (1) | CRFC-1512/120-A | CRFC-1512/120-C-A |
| 435 | 120 | 15 (6) | 10 (4) | 5 (2) | 4 (1.5) | CRFC-26/120-A | CRFC-26/120-C-A |
| 870 | 120 | 30 (12) | 10 (4) | 5 (2) | 4 (1.5) | CRFC-212/120-A | CRFC-212/120-C-A |
| 700 | 115 | 15 (6) | 13 (5) | 8 (3) | 5 (2) | CRFC-36/115-A | CRFC-36/115-C-A |
| 1400 | 240 | 30 (12) | 13 (5) | 8 (3) | 5 (2) | CRFC-312/240-A | CRFC-312/240-C-A |
| 2100 | 240 | 46 (18) | 13 (5) | 8 (3) | 5 (2) | CRFC-318/240-A | CRFC-318/240-C-A |
| 900 | 240 | 15 (6) | 18 (7) | 10 (4) | 6 (2.5) | CRFC-46/240-A | CRFC-46/240-C-A |
| 1800 | 240 | 30 (12) | 18 (7) | 10 (4) | 6 (2.5) | CRFC-412/240-A | CRFC-412/240-C-A |
| 2700 | 240 | 46 (18) | 18 (7) | 10 (4) | 6 (2.5) | CRFC-418/240-A | CRFC-418/240-C-A |
| 1130 | 240 | 15 (6) | 23 (9) | 13 (5) | 9 (3.5) | CRFC-56/240-A | CRFC-56/240-C-A |
| 2260 | 240 | 30 (12) | 23 (9) | 13 (5) | 9 (3.5) | CRFC-512/240-A | CRFC-512/240-C-A |
| 3390 | 240** | 46 (18) | 23 (9) | 13 (5) | 9 (3.5) | CRFC-518/240-A | CRFC-518/240-C-A |
| 4520 | 240** | 61 (24) | 23 (9) | 13 (5) | 9 (3.5) | CRFC-524/240-A | CRFC-524/240-C-A |
| 1350 | 240 | 15 (6) | 25 (10) | 15 (6) | 11 (4.5) | CRFC-66/240-A | CRFC-66/240-C-A |
| 2700 | 240** | 30 (12) | 25 (10) | 15 (6) | 11 (4.5) | CRFC-612/240-A | CRFC-612/240-C-A |
| 4000 | 240** | 46 (18) | 25 (10) | 15 (6) | 11 (4.5) | CRFC-618/240-A | CRFC-618/240-C-A |
* Add 3" for units with vestibules
** Dual 240 VAC circuits
CRWS Series Semi-Cylindrical Ceramic Heaters

| Watts |
Volts |
Dimensions in cm (") |
Without Vestibules Model No. |
With Vestibules Model No. |
| A DIM |
B DIM |
C DIM |
D DIM |
| 300 | 60 | 15 (6) | 10 (4) | 5 (2) | 4 (1.5) | CRWS-62/60-A | CRWS-62/60-C-A |
| 600 | 120 | 30 (12) | 10 (4) | 5 (2) | 4 (1.5) | CRWS-122/120-A | CRWS-122/120-C-A |
| 900 | 120 | 46 (18) | 10 (4) | 5 (2) | 4 (1.5) | CRWS-182/120-A | CRWS-182/120-C-A |
| 1200 | 240 | 61 (24) | 10 (4) | 5 (2) | 4 (1.5) | CRWS-242/240-A | CRWS-242/240-C-A |
| 425 | 120 | 15 (6) | 13 (5) | 8 (3) | 5 (2) | CRWS-63/120-A | CRWS-63/120-C-A |
| 850 | 120 | 30 (12) | 13 (5) | 8 (3) | 5 (2) | CRWS-123/120-A | CRWS-123/120-C-A |
| 1275 | 240 | 46 (18) | 13 (5) | 8 (3) | 5 (2) | CRWS-183/240-A | CRWS-183/240-C-A |
| 1700 | 240 | 61 (24) | 13 (5) | 8 (3) | 5 (2) | CRWS-243/240-A | CRWS-243/240-C-A |
| 565 | 120 | 15 (6) | 15 (6) | 10 (4) | 6 (2.5) | CRWS-64/120-A | CRWS-64/120-C-A |
| 1130 | 120 | 30 (12) | 15 (6) | 10 (4) | 6 (2.5) | CRWS-124/120-A | CRWS-124/120-C-A |
| 1700 | 240 | 46 (18) | 15 (6) | 10 (4) | 6 (2.5) | CRWS-184/240-A | CRWS-184/240-C-A |
| 2250 | 240 | 61 (24) | 15 (6) | 10 (4) | 6 (2.5) | CRWS-244/240-A | CRWS-244/240-C-A |
| 650 | 120 | 15 (6) | 23 (9) | 13 (5) | 9 (3.5) | CRWS-65/120-A | CRWS-65/120-C-A |
| 1300 | 240 | 30 (12) | 23 (9) | 13 (5) | 9 (3.5) | CRWS-125/120-A | CRWS-125/120-C-A |
| 1950 | 240 | 46 (18) | 23 (9) | 13 (5) | 9 (3.5) | CRWS-185/240-A | CRWS-185/240-C-A |
| 2600 | 240 | 61 (24) | 23 (9) | 13 (5) | 9 (3.5) | CRWS-245/240-A | CRWS-245/240-C-A |
| 850 | 120 | 15 (6) | 25 (10) | 15 (6) | 10 (4) | CRWS-66/120-A | CRWS-66/120-C-A |
| 1700 | 240 | 30 (12) | 25 (10) | 15 (6) | 10 (4) | CRWS-126/240-A | CRWS-126/240-C-A |
| 2550 | 240 | 46 (18) | 25 (10) | 15 (6) | 10 (4) | CRWS-186/240-A | CRWS-186/240-C-A |
| 3400 | 240** | 61 (24) | 25 (10) | 15 (6) | 10 (4) | CRWS-246/240-A | CRWS-246/240-C-A |
| 920 | 240 | 15 (6) | 28 (11) | 18 (7) | 13 (5) | CRWS-67/240-A | CRWS-67/240-C-A |
| 1840 | 240 | 30 (12) | 28 (11) | 18 (7) | 13 (5) | CRWS-127/240-A | CRWS-127/240-C-A |
| 2760 | 240 | 46 (18) | 28 (11) | 18 (7) | 13 (5) | CRWS-187/240-A | CRWS-187/240-C-A |
| 3680 | 240** | 61 (24) | 28 (11) | 18 (7) | 13 (5) | CRWS-247/240-A | CRWS-247/240-C-A |
| 1100 | 240 | 15 (6) | 30 (12) | 20 (8) | 15 (6) | CRWS-68/240-A | CRWS-68/240-C-A |
| 2200 | 240 | 30 (12) | 30 (12) | 20 (8) | 15 (6) | CRWS-128/240-A | CRWS-128/240-C-A |
| 3300 | 240 | 46 (18) | 30 (12) | 20 (8) | 15 (6) | CRWS-188/240-A | CRWS-188/240-C-A |
| 4400 | 240** | 61***(24) | 30 (12) | 20 (8) | 15 (6) | CRWS-248/240-A | CRWS-248/240-C-A |
| 2250 | 240 | 30 (12) | 36 (14) | 25 (10) | 20 (8) | CRWS-1210/240-A | CRWS-1210/240-C-A |
| 3400 | 240** | 46 (18) | 36 (14) | 25 (10) | 20 (8) | CRWS-1810/240-A | CRWS-1810/240-C-A |
| 4500 | 240** | 61***(24) | 36 (14) | 25 (10) | 20 (8) | CRWS-2410/240-A | CRWS-2410/240-C-A |
| 2700 | 240 | 30 (12) | 41 (16) | 30 (12) | 25 (10) | CRWS-1212/240-A | CRWS-1212/240-C-A |
| 4050 | 240** | 46 (18) | 41 (16) | 30 (12) | 25 (10) | CRWS-1812/240-A | CRWS-1812/240-C-A |
| 5400 | 240** | 61***(24) | 41 (16) | 30 (12) | 25 (10) | CRWS-2412/240-A | CRWS-2412/240-C-A |
| 3400 | 240** | 30 (12) | 48 (19) | 38 (15) | 33 (13) | CRWS-1215/240-A | CRWS-1215/240-C-A |
| 5100 | 240** | 46 (18) | 48 (19) | 38 (15) | 33 (13) | CRWS-1815/240-A | CRWS-1815/240-C-A |
| 6800 | 240** | 61***(24) | 48 (19) | 38 (15) | 33 (13) | CRWS-2415/240-A | CRWS-2415/240-C-A |
| 4100 | 240** | 30 (12) | 56 (22) | 46 (18) | 41 (16) | CRWS-1218/240-A | CRWS-1218/240-C-A |
| 6150 | 240** | 46 (18) | 56 (22) | 46 (18) | 41 (16) | CRWS-1818/240-A | CRWS-1818/240-C-A |
| 8200 | 240** | 61***(24) | 56 (22) | 46 (18) | 41 (16) | CRWS-2418/240-A | CRWS-2418/240-C-A |
| 4750 | 240** | 30 (12) | 64 (25) | 53 (21) | 48 (19) | CRWS-1221/240-A | CRWS-1221/240-C-A |
| 7125 | 240** | 46 (18) | 64 (25) | 53 (21) | 48 (19) | CRWS-1821/240-A | CRWS-1821/240-C-A |
| 9500 | 240** | 61***(24) | 64 (25) | 53 (21) | 48 (19) | CRWS-2421/240-A | CRWS-2421/240-C-A |
* Add 3" for units with vestibules
** Dual 240 VAC circuits
*** Using two 30 cm (12") long heaters; the indicated wattage is a total of two 30 cm (12") long heaters.
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Add 3" for units with vestibules
Ordering Example: (1) CRFC-156/60-A 350 watt heater with a 1.5" ID., 6" long without vestibules, price, $175
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Model
|
| |
Select CRFC for CRFC Series CRWS for CRWS Series
|
(2)
|
Dimension
|
| |
Select 1 for 1 in. (CRFC Series C DIM) 2 for 2 in. (CRFC Series C DIM) 3 for 3 in. (CRFC Series C DIM) 4 for 4 in. (CRFC Series C DIM) 5 for 5 in. (CRFC Series C DIM) 6 for 6 in. (CRFC Series C DIM or CRWS Series A DIM) 12 for 12 in. (CRWS Series A DIM) 18 for 18 in. (CRWS Series A DIM) 24 for 24 in. (CRWS Series A DIM) 15 for 1.50 in. (CRFC Series C DIM) 75 for 0.75 in. (CRFC Series C DIM) 125 for 1.25 in. (CRFC Series C DIM)
|
(3)
|
Dimension
|
| |
Select 2 for 2 in. (CRWS Series C DIM) 3 for 3 in. (CRWS Series C DIM) 4 for 4 in. (CRWS Series C DIM) 5 for 5 in. (CRWS Series C DIM) 6 for 6 in. (CRWS Series C DIM or CRFC Series A DIM) 7 for 7 in. (CRWS Series C DIM) 8 for 8 in. (CRWS Series C DIM) 10 for 10 in. (CRWS Series C DIM) 12 for 12 in. (CRWS Series C DIM or CRFC Series A DIM) 15 for 15 in. (CRWS Series C DIM) 18 for 18 in. (CRWS Series C DIM or CRFC Series A DIM) 21 for 21 in. (CRWS Series C DIM)
|
(4)
|
Volts
|
| |
Select 60 for 60 Vac 115 for 115 Vac 120 for 120 Vac 240 for 240 Vac
|
(5)
|
Vestibules
|
| |
Select Nothing(leave field blank) for heater without vestibules -C for heater with vestibules
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
 |
|
|
 |
|  |
|
Back to top
|
|