Pressure Compensation Device

DA284 Series  
1 year warranty New! CE
DA284 Series:Pressure Compensation Device
Click here for larger image.
   
High Degree of Protection
Semipermeable Membrane
Easy to Install
Corrosion Resistant (SS Model)
Food Safe (SS Model)

View related products - NEMA Enclosures
Scroll below to order View spec PDF

Pressure differentials in enclosures with a high degree of protection with respect to humidity and dust are a result of inside and outside temperature fluctuations. In case of negative pressure or vacuum, dust and humidity can be absorbed through the door seal and can enter the enclosure. As the humidity cannot exit the enclosure condensation may occur. The easy to install pressure compensation device DA284 provides the compensation of pressure at a protection degree of NEMA 4X (IP66). A semipermeable membrane inside the plug allows air and humidity to leave the enclosure. In the opposite direction, it only allows dry air into the enclosure while humidity and dust from the outside are blocked by the membrane.

SPECIFICATIONS
Art. No. Protection Type 1 Packing Unit Weight (Approx.): 28400.0-00 IP66 (EN 60529)/IPX9K (EN 40050-9) 2 pieces 90 g (0.20 lb) (45 g/piece) 28400.0-01 IP66 (EN 60529)/IPX9K (EN 40050-9) 1 piece 45 g (0.10 lb)
Mounting Thread: M40 x 1.5 with nut
Depth in Enclosure: Approx. 16 mm (0.63") [SS model 9 mm (0.35")]
Material: Plastic, light gray (SS model V2A- DIN 1.4404/AISI 316L)
Sealing: Sealing gasket NBR
Filter: Semipermeable membrane
Air Permeability: 1200l/h at a pressure difference of min. 70 mbar
Dimensions: Ø 60 x 37 mm (2.4 x 1.5")
SS Model: Ø 58 x 31 mm (2.3 x 1.2")
Fitting Position: Variable Operating/Storage Temperature: -45 to 70°C (-49 to 158°F)
Installation: Make cut-out Ø 40.5 + 0.5 mm (1.6 + 0.02") in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.


To Order (Specify Model Number)    
 Part Number   Availability   Price    Description    Qty.
 DA28428400000 in-stock    $14.00     NEMA 4X (IP66) (EN 60529)/IPX9K(EN 40050-9) ABS plastic 2 pcs  
 DA28428401000 in-stock    $76.00     NEMA 4X (IP66) (EN 60529)/IPX9K(EN 40050-9) stainless steel 1 pc  
All dollar amounts on this site are shown in US currency.

 Note: Comes with operator’s manual.

   