Omega.com - You're One-Stop Source for Process, Measurement and Control! (888) TCOMEGA (in US/Canada) or (203) 359- 1660 (for international)
Navigation Image Map  
search             

Two Stage Batch Controller/Ratemeter

DP-F30 Series  
1 year warranty CE Made in the USA
DP-F30 Series:Two Stage Batch Controller/Ratemeter
Click here for larger image.
   
$ 620.00  DP-F31
Displays Rate, Batch Total, and Grand Total
Separate K Factors for Rate and Total
12 to 24V Output
Optional 16-Point Linearization
NEMA 4X (IP65) Front-Panel Cover

View related products - Instrumentation and Accessories
Scroll below to order View spec PDF Related Products

The DP-F31 ratemeter/totalizer accepts 3 to 30 Vdc pulses, dry-contact closure, voltage, or milliamp inputs, and provides 2-stage SPDT relay outputs for batch control. The display is fully scalable for engineering units and may be toggled between batch total, rate, and grand total. The linearization option allows the user to select up to 16 different K factors over the input range for accurate indication of non-linear signals.

Other features include 12 to 24 Vdc output for powering up flowmeters; pulsed (0.1 to 9.9 s) or maintained outputs; input filtering for dry-contact closure (such as reed relays); local/remote reset; excitation for open-collector or mechanical contacts; user-programmable auto-reset of batch total (repeat cycles, 10 Hz max); security lockout to prevent unauthorized changes; factored pulse output; and analog output for rate or total (analog output not available with square root -SQRT option).

The DP-F30 series indicates rate to 5½-digits and total to 8-digits, with program and count data stored for up to 10 years if power is lost.

SPECIFICATIONS
Input Power: 110 Vac ±15% or 12 to 27 Vdc std.; 220 Vac ±15% optional
Current: Max 250 mA DC or 3.2 VA
Output Power: On AC-powered units
only: +24 or +12 Vdc @ 100 mA; unregulated (±5% worst case)
Pulse Inputs:
    DP-F31: 0 to 1 Vdc (low), 3 to 30 Vdc (high), 20 kHz max (min on/off 35 ìs)
    DP-F32: 4.7 kΩ pull up to +5 Vdc on input for pulsing with contact to ground or NPN collector transistor
Factored Output: Min on/off: 0.013 ms; open collector sinks 100 mA max from 1 to 30 Vdc max; max factored count speed is 20 kHz
Temperature:
    Operating: 0 to 54°C (32 to 130°F)
    Storage: -40 to 93°C (-40 to 200°F)
Accuracy: ±0.5% FS
Relay Outputs: 2 SPDT contacts rated for 10 A at 120/240 Vac or 28 Vdc
4 to 20 mA Output: ±0.5% FS accuracy; requires 3 to 24 Vdc supply voltage, non-inductive


To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description    Qty.
 DP-F31 in-stock    $620.00     Ratemeter/Totalizer, hi-level pulses  
 DP-F31-LIN in-stock    $683.00     Ratemeter/Totalizer, hi-level pulses with 16 point Linearization  
 DP-F31-LIN-MA in-stock    $815.00     Ratemeter/Totalizer, hi-level pulses with 16 point Linearization and a 4-20 mA output  
 DP-F32 in-stock    $620.00     Ratemeter/Totalizer, Dry relay pulses  
 DP-F32-MA in-stock    $752.00     Ratemeter/Totalizer, Dry relay pulses with 4-20mA output.  
 DP-F33 in-stock    $709.00     Ratemeter/Totalizer,4-20 mA  
 DP-F33-SQRT in-stock    $814.00     Ratemeter/Totalizer,4-20 mA with Square Root Extraction Function  
 DP-F33-220V-LIN in-stock    $772.00     220Vac, Ratemeter/Totalizer,4-20 mA input with linearization  
 DP-F34 in-stock    $709.00     Ratemeter/Totalizer, 0-5 Vdc  
 Accessories
 FLSC-AMP in-stock    $70.00     Amplifier for turbine meters with low level sinewave inputs and the DP-F31. FTB9500, FTB-100, FTB-900 units as examples.  
Special order models also available - view the full listing
All dollar amounts on this site are shown in US currency.

 Note: Comes with complete operator's manual.
 Ordering Example: (1) DP-F31-LIN ratemeter/totalizer, Hi-level pulses, 16 point Linearization, (1) FLSC-AMP Amplifier for Turbine Meters, (1) FTB9501 Low Flow Turbine Meter = $1827
 Part Number Builder
(1) (2)
Option Descriptions
(1) Model
  Select
DP-F31 for High level pulse 3 to 30 Vdc 20 kHz max
DP-F32 for High level pulse 3 to 30 Vdc 20 kHz max with 4.7 kOhm pull-up resistors to +5 Vdc for NPN
DP-F33 for 4 to 20 mA 250Ohm impedance
DP-F33-SQRT for 4 to 20 mA with square root extraction
DP-F34 for 0 to 5 Vdc 15 kOhm impedance
(2) Options
  Select
Nothing(leave field blank) for none
-MA for 4 to 20 mA analog output - not available with DP-F33-SQRT
-LIN for 16 point linearization
-220VAC for 220 Vac power
-RS232 for RS232 communications
-RS422 for RS422 communications
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
FTB9500 Series FTB9500 Series:
Low Flow Turbine Meters
FLSC-AMP FLSC-AMP:
Low Level Amplifier
   
Keywords:Two Stage Batch Controller/Ratemeter

   Back to top
© Copyright 2003-2009  |  OMEGA ENGINEERING, Inc.
OMEGA
Privacy Statement  |  Terms and Conditions
   MXV MMV | 72
VerisignAmex, Visa, Mastercard
Skip to navigation


Home Quick Order Products Literature My Omega Omega Info Contact Us Cart Help Global