The DPF708/808 series flow totalizers can
accumulate the mass, volume or length of an
object, and can provide batch control over the
accumulation. The DPF708 series has a single
input available in frequency, voltage or
current input models. The DPF808 series has
an additional input that is available in voltage,
current or direct temperature sensor input
versions. Abundant functions such as
retransmission, high/low alarm of momentary
flow and abnormal signal detecting. The
DPF808 series also has the ability to trigger
alarms for pressure or temperature. Square
root function is selectable, 8-digits of
accumulation value and 4-digits momentary
process value, small signal cut-out can be set
at any range.
The DPF808 series has temperature and
pressure compensation used for general gas,
saturated steam, superheated steam or
liquids. The compensation calculation is done
with standard look-up tables for high
accuracy in steam measurement applications.
Advanced computation algorithms insure
accuracy in flow measurements. Used as a
batch controller, it has 4-bit accumulator for
control and a separate 12-bit accumulator for
total sum. With high precision current input
models, the totalizer can provide
retransmission with 14 bit output resolution
and 0.2%FS output precision.
Size
Front Panel
Cut Out
Depth Behind Mounting Surface (mm)
Width(mm)
Height(mm)
Width(mm)
Height(mm)
1/8 DIN Vertical
48
96
45
92
100
1/8 DIN Horizontal
96
48
92
45
100
1/4 DIN
96
96
92
92
100
SPECIFICATIONS Frequency Input: 0 to 3200 Hz Temperature (DPF808 series): J, K or E thermocouple, 1 to 5, 0 to 5 Vdc or 4 to 20 mA
Pressure (DPF808 Series): 1 to 5, 0 to 5 Vdc or 4 to 20 mA
Accumulation Time: Fixed at 1 hour for flow accumulation, and the unit can be freely set for batch control.
Frequency Input Models: 0 to 3200Hz, the low level signal is 0 to 1V, the high level signal is 3 to 24V
Voltage Input Models: 1 to 5 V, 0 to 5 V, providing 24 Vdc/24 mA power output
Current Input Models: 4 to 20 mA, 0 to 20 mA, 0 to 10 mA
Temperature Input (DPF808 Series): K (0 to 999C), E (0 to 800C), J (0 to 999C) RTD Pt100 (-200 to 600C)
Pressure Input (DPF808): 1 to 5 Vdc, 0 to 5 Vdc
Current Input (DPF808): 4 to 20 mA, 04 to 20 mA
Current Output: 4 to 20 mA
Measurement Accuracy: ±0.2% FS, for temperature, pressure, frequency, and momentary flow without temperature or pressure compensation.
Temperature/Pressure Compensation Method (DPF808 Series): General Gas: Temperature-pressure compensation (calculated with ideal gas equation)
Saturated Steam: Temperature or pressure compensation (calculated with steam tables)
Calculation Accuracy for Temperature-Pressure Compensation: The calculation error is <0.3% FS, and after compensation, the overall error is <0.5% FS
Accumulation Accuracy: The error is <0.01% FS
Power Supply: 100 to 240 Vac, -15%, +10%/50 to 60Hz; or 24 Vdc/Vac, -15% (optional)
Power Consumption: 5 W
Operating Ambient: Temperature -10 to 60 C; humidity 90% RH
† All dollar amounts on this site are shown in US currency.
Note: Comes with mounting hardware and user's manual. * Insert input code: "F" (frequency), "V"(voltage) or "C" (current). ** Insert dual input code: "FT" (frequency/temperature), "FC" (frequency/current), "VT" (voltage/temperature), "VC" (voltage/current), "CT" (current/temperature) or "CC" (current/current). For models with 24Vdc power add "-24V" to the model number and $10 to the price. (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Part Number Builder
Option Descriptions
(1)
Series
Select 7 for Single Input 8 for Dual Input
(2)
Style
Select 18 for 1/4 DIN Totalizer 28 for 1/4 DIN Totalizer with bar graph 38 for 1/8 DIN Vertical totalizer 48 for 1/8 DIN Horizontal totalizer
(3)
Inputs
Select F for Frequency (single input only) V for Voltage (single input only) C for Current (single input only) FT for Frequency/Temperature (dual input only) FC for Frequency/Current (dual input only) VT for Voltage/Temperature (dual input only) VC for Voltage/Current (dual input only) CT for Current/Temperature (dual input only) CC for Current/Current (dual input only)
(4)
Outputs
Select -DC1-DC2 for 2 DC pulse outputs -DC1-R2 for DC pulse and relay outputs -R1-R2 for 2 relay outputs
(5)
24Vdc Power
Select Nothing(leave field blank) for None -24V for Add 24Vdc Power
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.