DIGITAL PRESSURE GAUGE (DPG) SANITARY, CLEAN-IN-PLACE MODELS |
| DPG409S Series |
|
 |
|
|
SANITARY/CLEAN-IN-PLACE DIGITAL PRESSURE GAUGE
 |
| Click for larger image. |
|
|
$
805.00
DPG409S15-500G
|
| |
Easy to Read 25 mm (1") Backlit LCD Display
|
| |
High 0.08% Accuracy Typical
|
| |
Hi and Lo Alarms Standard
|
| |
MIN/MAX/AVG Reading
|
| |
User Selectable Analog Output 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA
|
| |
Data Logging and Charting Software Included
|
| |
Wireless Transmitter Option Sends Reading to a Remote Location
|
| |
Tested to Industrial CE Standards
|
| |
Battery Powered with Long Battery Life
|
| |
Analog Output Standard
|
| |
Wireless Transmitter Optional
|
View related products - Pressure Gauges
|
| |
|
|
|
 |
OMEGA’s DPG409S Sanitary/
CIP digital pressure gauges
incorporate a rugged 316 SS
enclosure designed for washdown
and marine applications with a
precision 0.08% accuracy pressure
transducer with 316L SS wetted
parts and body. The result is an
extremely durable digital pressure
gauge designed to survive harsh
industrial environments. The large
25 mm (1") display is easy to read
at a distance up to 11 m (35').
Models are available in Gauge,
Compound Gauge, Absolute,
Vacuum and Barometric pressure
ranges. Standard features include
a highly stable silicon sensor,
selectable MIN/MAX and AVG
readings, Hi and LO alarms and an
externally powered user selectable
analog output. An optional wireless
transmitter feature with software
allows the signal to be transmitted
to a remote location such as a PC
for charting and data logging. Power
is from an internal long life battery
(included) or an externally supplied
dc voltage source. Each unit is
supplied with configuration software
that allows the user to connect to a
PC via a standard USB connection
(cable included) and select a
variety of user configurable features
including update rate, units,
and backlight.
SPECIFICATIONS RoHS Compliant
CE Compliant: Meets industrial emissions and immunity standard IEC61326 for industrial locations
Accuracy: ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined)
Calibration: 5-Pt NIST traceable Calibration with zero and span values, Calibrated in horizontal direction (Compound Gage models calibrated in positive direction only).
Zero Balance: ±0.5% FS typical ±1% max (For ranges =2.5 psi ±1% Typ. ±2% max)
Span Setting: ±0.5% FS typical ±1% max (For ranges =2.5 psi ±1% Typ. ±2% max) Storage/Operating Temperature
Range: -15 to 115°C (5 to 240°F) Compensated Temperature Range:
Ranges ≤5 psi: 4.4 to 60°C (40 to 140°F)
Ranges >5 psi: -4 to 85°C (25 to 150°F)
Thermal Effect (Over Compensated Range):
Zero and Span shift over Compensated Range
Ranges ≤25 psi: Zero: 1.00% Span: 0.70%
Range = 5 psi: Zero: 0.80%Span: 0.50%
Ranges > 5psi: Zero: 0.50% Span: 0.50%
26B & 26HB Barometric Range:
Zero: 0.90% Span: 0.50%
Minimum Isolation Between Case and Output Terminations: 100M O @ 50 Vdc
Analog Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required)
Note: Compound gage ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc.
Analog Output Cable: 2.7 m (8.9') with ferrite core included
Analog Output Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m)
Pressure Cycles: 250,000, minimum
Long Term Stability (1-Year): ±0.1% FS Typ.
Fill Fluid: NEOBEE M5 Food Grade Approved to 3A Sanitary Specification 74-03
Environmental Protection: NEMA 4X (IP65) depending upon electrical termination
Pressure Rating: 1½ and 2" Tri-Grip Fitting (compatible with Tri-Clamp®): 600 psi using suitable clamp (600 psi on 1½" Tri-Clamp® only)
Over Pressure: 4 x rated pressure to maximum rated flange pressure
Secondary Containment: 6 x rated pressure to a maximum of 2000 psi (not in clamp)
Display: 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1") character height
Computer Interface: UBS connection for set-up, cable included
Sample/Display Rate: User selectable from 0.25 to 10 sec. (preset to 1/sec)
Power: One 3.6V lithium 8.4 Ah capacity (C cell) Included (Two included with Wireless Option)
Battery Life (Typical): Up to 4-years
Enclosure Material: 316 Stainless Steel and ABS center gasket
Enclosure Finish: Electropolished Enclosure Environmental Rating: Weatherproof, NEMA 4X (IP65)
Connection Location: Lower (head rotates to position display) Front Panel Functions
Backlight: Manually turns backlight on/off
Min/Max: Recalls min/max values
Zero/Clear: Zeros display or clears min/max Software Settings (via USB)
Update Rate: 4 options, 10, 5, 2, 1 times per second
Units: psi, inHg, inH2O, bar, mbar, hPa, units must be specified at time of order
Lock: Allows the lock-out of front panel functions
Alarms: User selectable “High” and “Low” alarm limits. (Open Collector)
Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power)
Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (optional): Channel Number, Transmission rate, alarms, sensor offset, chart recording, data logging
Calibrate: Zero and Span Overrange Indication: “_ _ _ _”
Wireless Option Sepcifications:
Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver
Carrier: ISM 2.4 GHz
RF Output: 10 dBm (10 mW)
Range of RF Link:
Outdoors (Line of Sight): Up to 120 m (400')
Indoors/Urban: Up to 40 m (130')
Included Software: Requires Windows® 7 (32 bit); XP, Vista
Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included
Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level
Dimensions:
Display: 115 D x 89 W x 74 mm H (4.5 x 3.5 x 2.9")
Sensor: 72 to 89 mm L (2.8 to 3.5") below display
Weight: 900 g (2 lb) Typical depending upon configuration
To Order with 2" flange change S15 in model number to S20. No extra charge. To Order with Wireless Transmitter Option add "-W" suffix, add $100.
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual, set-up and configuration software, magnetic stylus, USB cable, 2.7 m (9') analog output cable with ferrite core, one 3.6V lithium C cell battery (two with wireless option) and 5-pt NIST traceable calibration. Wireless option also includes charting and databasing software.
Ordering Example: (1) DPG409S15-100G Digital gage with 1-1/2" fitting, 0 to 100 psig, $805.00
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Sanitary Fitting
|
| |
Select 15 for 1.5 inches Tri-Grip 20 for 2 inch Tri-Grip
|
(2)
|
Range
|
| |
Select -10WG for 0 to 10 inH2O Gauge -001G for 0 to 1 Gauge -2.5G for 0 to 2.5 Gauge -005G for 0-5 Gauge -015G for 0-15 Gauge -030G for 0-30 Gauge -050G for 0-50 Gauge -100G for 0-100 Gauge -150G for 0-150 Gauge -250G for 0-250 Gauge -500G for 0-500 Gauge -600G for 0-600 Gauge -005A for 0-5 Absolute -015A for 0-15 Absolute -030A for 0-30 Absolute -050A for 0-50 Absolute -100A for 0-100 Absolute -150A for 0-150 Absolute -250A for 0-250 Absolute -500A for 0-500 Absolute -600A for 0-600 Absolute -10WV for 0 to 10 inH2O Vacuum -001V for 0 to -1 Vacuum -2.5V for 0 to -2.5 Vacuum -005V for 0 to -5 Vacuum -015V for 0 to -15 Vacuum -10WCG for +/-10 inH2O Compound Gauge -001CG for +/-1 Compound Gauge -2.5CG for +/-2.5 Compound Gauge -005CG for +/-5 Compound Gauge -015CG for +/-15 Compound Gauge -32B for 0 to 32inHg Barometric -16B for 16 to 32inHg Barometric -32HB for 0-1100 hPa Barometric -16HB for 550-1100 hPa Barometric -26HB for 880-1100 hPa Barometric
|
(3)
|
Wireless Option
|
| |
Select for -W for Wireless Option
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| |
|
 |
|
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Related Products
|
 |
 |
 |
 |
 |
 |
|
Related Products
|
 |
DPG409 Series:
|
|
Digital Pressure Gauge (DPG) with Analog Output and Optional Wireless Transmitter
|
 |
 |
|
 |
DPG409_Diff Series:
|
DIGITAL PRESSURE GAUGE (DPG) DIFFERENTIAL PRESSURE HIGH 0.08% ACCURACY
|
 |
 |
|
|
|
 |
 |
|
|