100 Ω Platinum (Pt) RTD Element, 0.00385 Curve
2 or 3 Wire Configuration
0.2% Accuracy
Cable Resistance Compensation up to 10 Ω
Upscale Break Protection
Response Time < 250 mS
Galvanic Isolation Between Input, Output and Power

View related products - Signal Conditioners
Scroll below to order View spec PDF Manuals Related Products

The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.

The DRF-RTD RTD signal conditioners accept 2 or 3 wire 100 platinum RTDs as input and provide an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options,
24 Vdc, 120 Vac and 240 Vac.

The DRF-RTD are ideally suited for industrial applications. All models mount on a standard 35 mm DIN rail and provide galvanic isolation between input, output and power up to 3500 Veff (model specific). Module response time is 250 mS or less.

Range Code Table for DRF-RTD
Range CodeRange
-25/75C-25 to 75°C
0/100C0 to 100°C
0/200C0 to 200°C
0/300C0 to 300°C
0/450C0 to 450°C
0/600C0 to 600°C


SPECIFICATIONS

RTD: 2 or 3 wire 100Ω platinum
RTD: α=0.00385
Accuracy: <0.2% full scale
Linearity: <0.1% full scale
Thermal Drift: 250 ppm/°C typical
Response Time: <250 mS (90% of signal)
RTD Excitation: 1 Vdc
Input Impedance: Measured with a "Wheatstone" bridge. Bridge to positive through a 100 . resistance, Bridge to negative through a 10 KΩ resistance

Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz, 115 Vac ±10% 50/60 Hz
Power Consumption: <3.8 VA
Output: 4 to 20 mA and 0 to 10 Vdc
 

Maximum Voltage Output: 11 Vdc approx.
Minimum Voltage Output: -1 Vdc approx.
Minimum Load Resistance (Voltage): >1 KΩ Maximum Current Output: 22 mA approx.
Maximum Current Output: -1.5 mA approx.
Maximum Load Resistance (current): >400 Ω

Electrical Connections: Plug-in screw terminals
Protection: IP-30

MECHANICAL DIMENSIONS
Weight:
(DC Powered Models): 120 g (4.2 oz)
(AC Powered Models): 200 g (7 oz)
Dimensions:
(DC Powered models):
110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7")
(AC Powered models):
110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7")
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -20 to 70°C (-4 to 158°F)


To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description RoHS   Qty.
 Below are examples of popular models. See the Part Number Builder to order any available model.
 DRF-RTD-115VAC--50/150C-4/20 in-stock    $180.00     RTD signal conditioner with -50 to 150C range, 4 to 20mA output and 115Vac power RoHS compliant
 DRF-RTD-115VAC-0/200C-4/20 2 Weeks    $180.00     RTD signal conditioner with 0 to 200C range, 4 to 20mA output and 115Vac power RoHS compliant
 DRF-RTD-115VAC--25/75C-0/10 3 Weeks    $180.00     RTD signal conditioner with -25 to 75C range, 0 to 10Vdc output and 115Vac power RoHS compliant
All dollar amounts on this site are shown in US currency.

 Ordering Example: (1) DRF-RTD-115VAC--50/150C-4/20 RTD signal conditioner with -50 to 150C range, 4 to 20mA output and 115Vac power = $180
 Part Number Builder
(1) (2) (3)
DRF-RTD- - -
Option Descriptions
(1) Power
  Select
115VAC for 115 Vac power
230VAC for 230 Vac power
24VDC for 24 Vdc power
(2) Range Code
  Select
-25/75C for -25 to 75 degree C
-50/150C for -50 to 150 degree C
0/100C for 0 to 100 degree C
0/200C for 0 to 200 degree C
0/300C for 0 to 300 degree C
0/450C for 0 to 450 degree C
0/600C for 0 to 600 degree C
(3) Output
  Select
4/20 for 4 to 20 mA
0/10 for 0 to 10Vdc
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
   DRF-TC: Thermocouple Signal Conditioner
   DRF-RES and DRF-POT: Resistance and Potentiometer Input Input Signal Conditioners
   DRF-PR: DRF-PR Process Input Signal Conditioners
   DRF-LC: DRF-LC Load Cell Input Signal Conditioner
   DRF-VDC and DRF-VAC: DC and AC Voltage Input Signal Conditioners
   DRF-IDC and DRF-IAC: DC and AC Current Input Signal Conditioners
   DRF-FR: DRF-FR Freqency Input Signal Conditioner
   
Keywords:RTD Input Signal Conditioner

   Back to top
© Copyright 2003-2008  |  OMEGA ENGINEERING, Inc.
OMEGA
Privacy Statement  |  Terms and Conditions
   MXV MMV | 71
VerisignAmex, Visa, Mastercard
Skip to navigation


Home Quick Order Products Literature My Omega Omega Info Contact Us Cart Help Global