In-Line Ultrasonic Flowmeter |
| FDT100 Series |
|
 |
|
|
|
|
|
$
2,538.00
FDT103
|
| |
Economical Ultrasonic Flowmeter for Water Service
|
| |
Battery Powered
|
| |
Displays Flow Rate and Total
|
| |
Extended Low Flow Range
|
| |
Virtually No Pressure Loss
|
| |
No Moving Parts for Long Life
|
| |
Nist 3 Point Certificate Included
|
View related products - Doppler/Transit-Time Ultrasonics
|
| |
|
|
|
 |
The FDT100 Series comprises advanced-technology water flowmeters. This series uses transit-time
ultrasonic technology in which the signal is transmitted and received alternately between 2 flow
sensors and the “time of flight” determines the flow rate. The battery-powered transmitter comes
in the user’s choice of an integrally mounted display or a remote-mount version. Applications include both
commercial and consumable water measurement. Long-term stability and a wide measurement range make it
possible not only to measure water consumption, but also to monitor systems for water leakage. Because
the FDT100 Series has no moving parts, system pressure loss is minimal and filtration is not required.
Display flow rate or total at the push of a button. Installation is aided by 150-lb ANSI flanges in sizes
from 2 to 8".
SPECIFICATIONS
Accuracy: ±2% of reading; ±5% below minimum transition rate
Fluid Temperature: 0 to 50°C (32 to 122°F)
Maximum Pressure: 230 psig
Enclosure: IP67 (integral mount version)
Electronic Housing: Aluminum alloy with plastic cover
Display: 7-segment, 8-digit, single-line LCD
Current Output: 4 to 20 mA/DC current (requires 8 to 24 Vdc supply)
Open Collector Output: 5 to 30 Vdc, 1 mA max
Flange: ANSI 150# or DIN
Meter Body: Cast iron
Power Supply: Internal 3.6V battery (included), 1 to 2 year life
| ANSI Size Rate Information |
| ANSI Flange Size |
2 |
2½ |
3 |
4 |
5 |
6 |
8 |
| Overload FLow Rate Qs(GPM) |
130 |
220 |
350 |
530 |
880 |
1320 |
1585 |
| Nominal FLow Rate Qp(GPM) |
65 |
110 |
175 |
265 |
440 |
660 |
1100 |
| Transitional Flow Rate Qt(GPM) |
13 |
22 |
35 |
53 |
88 |
132 |
220 |
| Minimum FLow Rate Qmin(GPM) |
2 |
3.3 |
5.3 |
8 |
13.2 |
20 |
33 |
| Pulse Output Constant ki(Gals/pulse) |
5 |
10 |
10 |
15 |
30 |
30 |
30 |
| DIN Size Rate Information |
| DIN Flange Size |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
| Overload FLow Rate Qs(m³/hr) |
12 |
20 |
30 |
50 |
80 |
120 |
200 |
300 |
360 |
| Nominal FLow Rate Qp(m³/hr) |
6 |
10 |
15 |
25 |
40 |
60 |
100 |
150 |
250 |
| Transitional Flow Rate Qt(m³/hr) |
0.48 |
0.8 |
3 |
5 |
8 |
12 |
20 |
30 |
50 |
| Minimum FLow Rate Qmin(m³/hr) |
0.12 |
0.2 |
0.45 |
0.75 |
1.2 |
1.8 |
3 |
4.5 |
7.5 |
| Pulse Output Constant ki(liters/pulse) |
10 |
25 |
25 |
50 |
50 |
100 |
100 |
100 |
100 |
NOTE: HEAVY WEIGHT - OVERWEIGHT SHIPPING CHARGES MAY APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE,
INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR
CARRIER ACCOUNT.
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with battery, 3-Point Nist Calibration Certificate and operator's manual.
For a 4 point Nist calibration, add suffix "-NIST4" to the model number add $520 to the price.
For an 8 point Nist calibration, add suffix "-NIST8" to the model number add $920 to the price.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) FDT104-R 4" 150# ANSI flanged magnetic flowmeter, $2990
|
|
 |
|
 |
|  |
|