Air/Water Flow Sensors With 0 to 5 Vdc Output |
| FLR1000 |
|
 |
|
|
Air/Water Flow Sensors With 0 to 5 Vdc Output
 |
| Click for larger image. |
|
|
$
255.00
FLR1001
|
| |
0 to 5 Vdc Linear Output Signal
|
| |
Power Input 12 Vdc or 24 Vdc (depending on the model)
|
| |
Ranges from 20 to 100 ml/min, 100 to 500 L/min
|
| |
1% Accuracy for Liquids/3% Accuracy for Gasses
|
| |
Highly Repeatability
|
| |
Stainless Steel Models Available
|
View related products - Turbine and Paddle Wheel Flowmeters
|
| |
|
|
|
 |
FLR1000 Series flow sensors can measure extremely
low flow rates from 20 mL/min to 500 L/min. These
sensors are suitable for a wide variety of industrial,
commercial, and laboratory flow applications.
FLR1000 Series flow sensors operate on 12 Vdc
power and are designed for incorporation into data
acquisition systems that supply 12.5 Vdc to sensors
and receive 0 to 5 Vdc linear signals in return.
Because of their cost effectiveness, FLR1000 Series
units may replace conventional glass tube and ball
flowmeters in applications in which an electrical signal
proportional to flow rate is desired.
The FLR1000 Series uses a Pelton-type turbine wheel
to determine the flow rate of the gas. The rotation rate
of the turbine wheel is linear over a wide dynamic
range. The electro-optical system consists of a diode
emitting energy in the infrared spectrum. Light energy
is alternatively reflected and absorbed from "spokes"
deposited on the small turbine wheel. This reflected
light energy is detected by a photodiode. Thus, as the
turbine wheel rotates in response to gas flow rate,
electrical pulses are generated. Processing circuitry
provides a DC voltage output proportional to the flow
rate. For example, output signal is 1.0 Vdc at 20% of
rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc at
80% of rated flow, and 5.0 Vdc at 100% of rated flow.
Sensors can handle 20% above their rated flow
without being damaged.
For liquid flow metering with integrated rate display,
the FLR1000ST-D Series has been setting the pace.
Their advanced Pelton-turbine design provides high
turndown ratios, fast response, and repeatable
accuracy. A 0 to 5 Vdc analog output is standard.
Featuring a 3½-digit display of flow rate in engineering
units, these flowmeters are perfect for any laboratory
or test facility. For higher-pressure applications or
where metal may be required, the FLR1000ST Series
is the solution.
Designed for applications where
stainless steel may be required, the
FLR1000ST Series flowmeters are
rated to 500 psig. These units are
available to cover flow ranges from
13 mL/min to 10 L/min. A 0 to 5 Vdc
or 4 to 20 mA analog output is
standard with all units; Voltage
output models are also available
with an additional pulse output, or
with a 3½ digit LCD readout.
SPECIFICATIONS
FLR1000 Series
Accuracy: ±3% FS
Display: 3½-digit LCD, 22 mm (7/8") H
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical)
Power Requirement: 11.5 to 15 Vdc regulated, 30 mA (typical)
Standard Sensor Material: 40% glass filled polyphenelene sulfide, glass window, stainless steel bearing support; sapphire shaft and bearing; FKM rubber O-rings standard
Pressure Rating: 40 psi at 20°C (68°F) for gas, 100 psi for liquid, 500 psi for brass units using liquid services
Temperature Rating: 0 to 50°C (32 to 122°F)
Temperature Sensitivity: ±0.2%/°C
Linearity: ±3% FS
Repeatability: ±0.5% FS from 50 to 100% of rated max flow for gas; ±0.2% FS for liquid
Cable Assembly: 0.9 m (3') cable length
Dimensions:
Display: 76 x 44 x 89 mm (3 x 1.75 x 3.5")
Non-Display: 60 x 42 x 37 mm (2.35 x 1.65 x 1.25")
Pressure Sensitivity: ±0.07%/mm Hg (using air at 1 to 3 atm)
Mounting: Holes for #4 screw provided
FLR1000ST Series
Accuracy/Linearity: ±1% FS
Repeatability: ±0.2% FS
Pressure Rating: 34 bar (500 psig), max
Operating Ambient: 5 to 55°C (41 to 131°F)
Storage Ambient: 0 to 70°C (32 to 158°F)
Temperature Sensitivity: ≤±0.2% FS/°C
Wetted Parts: 316 SS, epoxy, Pyrex® glass, PPS, FKM O-rings, sapphire bearings
Filtration (Recommended): 25 microns or less
Analog Output: Linear 0 to 5 Vdc or 4 to 20 mA; non-isolated signal
Pipe Connections: 316 SS compression tube fittings, provided
Electrical Connections: 4-pin male connector for both power and signal; included with 0.9 m (3') cable
Power:
Voltage Output Models: 11.5 to 12.5 Vdc (0.4 W @ 12 Vdc)
Current Output Models: 18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA
| Gas Flow Models - PPS Construction |
Model No. No Display |
Model No. with Display |
Flow Range |
Max Pressure Drop |
Acetal Tube Fitting |
| FLR1001 |
FLR1001-D |
20 to 100 mL/min |
20 inH2O |
1/8" |
| FLR1002 |
FLR1002-D |
40 to 200 mL/min |
8 inH2O |
1/8" |
| FLR1003 |
FLR1003-D |
100 to 500 mL/min |
2 inH2O |
1/8" |
| FLR1004 |
FLR1004-D |
200 to 1000 mL/min |
2 inH2O |
1/8" |
| FLR1005 |
FLR1005-D |
0.4 to 2 L/min |
2 inH2O |
1/4" |
| FLR1006 |
FLR1006-D |
1.0 to 5 L/min |
2 inH2O |
1/4" |
| FLR1201 |
FLR1201-D |
2.0 to 10 L/min |
3 inH2O |
1/4" |
| FLR1202 |
FLR1202-D |
4.0 to 20 L/min |
3 inH2O |
3/8" |
| FLR1203 |
FLR1203-D |
10 to 50 L/min |
3 inH2O |
3/8" |
| FLR1204 |
FLR1204-D |
20 to 100 L/min |
3 inH2O |
1/2" |
| FLR1205 |
FLR1205-D |
40 to 200 L/min |
5 inH2O |
1/2" |
| FLR1206 |
FLR1206-D |
100 to 500 L/min |
20 inH2O |
1/2" |
| Liquid Flow Models - PPS Construction |
Model No. No Display |
Model No. with Display |
Flow Range |
Max Pressure Drop |
Acetal Tube Fitting |
| FLR1007 |
FLR1007-D |
13 to 100 mL/min |
10 psi |
1/8" |
| FLR1008 |
FLR1008-D |
20 to 200 mL/min |
10 psi |
1/4" |
| FLR1009 |
FLR1009-D |
50 to 500 mL/min |
10 psi |
1/4" |
| FLR1010 |
FLR1010-D |
100 to 1000 mL/min |
6 psi |
1/4" |
| FLR1011 |
FLR1011-D |
0.2 to 2 L/min |
6 psi |
1/4" |
| FLR1012 |
FLR1012-D |
0.5 to 5 L/min |
6 psi |
3/8" |
| FLR1013 |
FLR1013-D |
1.0 to 10 L/min |
10 psi |
3/8" |
| Liquid Flow Models - 316 SS Construction |
Model No. No Display 0-5 V & pulse Outputs |
Model No. No Display 4-20 mA |
| FLR1007ST |
FLR1007ST-I |
FLR1007ST-D |
13 to 100 mL/min |
10 psi |
1/8" |
| FLR1008ST |
FLR1008ST-I |
FLR1008ST-D |
20 to 200 mL/min |
10 psi |
1/4" |
| FLR1009ST |
FLR1009ST-I |
FLR1009ST-D |
50 to 500 mL/min |
10 psi |
1/4" |
| FLR1010ST |
FLR1010ST-I |
FLR1010ST-D |
100 to 1000 mL/min |
6 psi |
1/4" |
| FLR1011ST |
FLR1011ST-I |
FLR1011ST-D |
0.2 to 2 L/min |
10 psi |
1/4" |
| FLR1012ST |
FLR1012ST-I |
FLR1012ST-D |
0.4 to 5 L/min |
10 psi |
3/8" |
| FLR1013ST |
FLR1013ST-I |
FLR1013ST-D |
1.0 to 10 L/min |
10 psi |
3/8" |
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 0.9 m (3') cable and operator’s manual.
† For optional 3-PT NIST Calibration with certificate for gas (FLR1001 to FLR1006 and FLR1200 to FLR1206) add suffix "-NISTAIR" to model number, add $350 to price.
†† For optional 3-PT NIST Calibration with certificate for liquid (FLR1007 to FLR1013) add suffix "-NISTWATER" to model number, add $300 to price.
Please dowload specification page for all available options.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) FLR1012 liquid flow sensor, 0.2 to 5.0 l/min water, $305.00, plus (1) DP25B-E 1/8 DIN Panel meter with 12 volts excitation, $250.00, $305.00 + 250.00 = $555.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Manual, Related Products
|
 |
 |
 |
 |
 |
 |
|
Product Manual
|
|
Download
FLR1000, 1000BR, 1000ST Series
- Flow Sensors & Meters for Liquids
|
|
Download
FLR1000, 1000BR Series - Flow Sensors & Meters for Gases
|
|