Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Omega.com - Your One-Stop Source for Process, Measurement and Control! (888) TCOMEGA (in US/Canada) or (203) 359- 1660 (for international)
Navigation Image Map  
search
      
 

Water Flowmeters and Controllers for Low Flow

FLR-1600A AND FLV-4600A Series   
1 year warranty CE Made in the USA RoHS
 
Water Flowmeters and Controllers for Low Flow
FLR-1600A AND FLV-4600A Series:Water Flowmeters and Controllers for Low Flow
Click for larger image.
   
$ 1,460.00  FLR-1604A
Response Time of 20 milliseconds Typical (Meter)
Turndown Ratio of 50:1
Push Button Tare (with Display)
Accuracy of ア2% Full Scale
NIST Traceability Standard
Portable versions available
Minimum flow is 0.01 ml/min

View related products - Turbine and Paddle Wheel Flowmeters

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

The OMEGAョ Series FLR-1600A and FLV-4600A series flowmeters and controllers use two of the best studied physical properties of liquids to measure flow: Pressure and Viscosity. Differential pressure measurement, across a laminar flow element, results in a flow meter that is inherently linear. OMEGAョ flow meters measure differential pressure within that laminar region to achieve a turndown of 50:1 typical and the accuracy is ア2.0% of full scale. It uses the same technology as the laminar gas mass flow and volumetric flow meters, FMA-1600A and FLV-1600A. There are no moving parts to wear out.

The FLR-1600A Series is a Volumetric Water Flowmeter. The unique method of flow detection allows the meter to measure extremely low flow rates at an affordable price. The FLR-1600A Series was designed with deionized water in mind. These flowmeters are available in ranges of 500 microliters per minute full scale to 10 liters per minute full scale.

The FLR-1600A water meter provides data on the flow rate and temperature via the standard local display and the RS232 serial output. An optional gauge pressure sensor is available on the secondary output model "-P".

The FLV-4600A Series Water Flow Controller utilizes a proportional valve coupled to a flowmeter body creating a unique in-situ closed-loop flow controller system. Measurements are taken within the laminar region of the flow meter and the integral PID controller positions the valve according to the flow set points. The controllers can accept an RS-232 or the 0-5 Volt control input signal depending on what is preferred. Independent of the set point voltages, the controllers can be configured for single or dual output of the same or different voltages and/or different parameters such as temperature and flow. This is possible because of our laminar flowmeter design that incorporates solid-state Differential and Temperature Sensors on the standard model to determine flow in an inherently linear system. An optional , an Absolute Gauge Pressure Sensor is available on the "-P" secondary output models. The result is a fast responding linear flow meter with multiple outputs. All these parameters are simultaneously visible with our dynamic display that includes a push button operator interface. Water flow controllers are available from 50 milliliters per minute full scale to 500 milliliters per minute full scale.

Model No.
Water Flow Meter
Model No.
Water Flow Controller
Min ΔP = 5 PSIG
Connection Flow Range
FLR-1601A末末10-32 Thread0 to 0.5 sccm
FLR-1602A末末10-32 Thread0 to 1 sccm
FLR-1614A末末1/8 FNPT0 to 2 sccm
FLR-1615AFLV-4615A1/8 FNPT0 to 5 sccm
FLR-1603AFLV-4603A1/8 FNPT0 to 10 sccm
FLR-1616AFLV-4616A1/8 FNPT0 to 20 sccm
FLR-1604AFLV-4604A1/8 FNPT1 to 50 sccm
FLR-1617AFLV-4617A1/8 FNPT2 to 100 sccm
FLR-1618AFLV-4618A1/8 FNPT4 to 200 sccm
FLR-1619AFLV-4619A1/8 FNPT0 to 500 sccm
FLR-1620AFLV-4620A1/4 FNPT0 to 1 SLPM
FLR-1605AFLV-4605A1/4 FNPT0 to 2 SLPM
FLR-1606AFLV-4606A1/4 FNPT0 to 5 SLPM
FLR-1607A末末1/4 FNPT0 to 10 SLPM


 
 MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)    
 Part Number   Availability   Price   Description RoHS   Qty.
 Water Flowmeter
 FLR-1601A In Stock   $2,035.00    0.5 CCM, 10 to 32 UNF Thread RoHS compliant
 FLR-1601A-B 4 Weeks   $2,230.00    0.5 CCM, 10 to 32 UNF Thread, portable version †† RoHS compliancy undetermined
 FLR-1601A-I 4 Weeks   $2,100.00    0.5 CCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
 FLR-1601A-I2 4 Weeks   $2,170.00    0.5 CCM, 10 to 32 UNF Thread, two 4 to 20 mA output RoHS compliant
 FLR-1601A-V2 4 Weeks   $2,100.00    0.5 CCM, 10 to 32 UNF Thread, two 0 to 5 V output RoHS compliant
 FLR-1602A 4 Weeks   $2,035.00    1 CCM, 10 to 32 UNF Thread RoHS compliant
 FLR-1602A-B 4 Weeks   $2,230.00    1 CCM, 10 to 32 UNF Thread, portable version †† RoHS compliancy undetermined
 FLR-1602A-I 4 Weeks   $2,100.00    1 CCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
 FLR-1602A-I2 4 Weeks   $2,170.00    1 CCM, 10 to 32 UNF Thread, two 4 to 20 mA output RoHS compliant
 FLR-1602A-V2 4 Weeks   $2,100.00    1 CCM, 10 to 32 UNF Thread, two 0 to 5 V output RoHS compliant
 FLR-1614A 4 Weeks   $1,845.00    2 CCM, 1/8 FNPT RoHS compliant
 FLR-1614A-B 4 Weeks   $2,035.00    2 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1614A-I 4 Weeks   $1,910.00    2 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1614A-I2 4 Weeks   $1,975.00    2 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1614A-V2 4 Weeks   $1,910.00    2 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1615A 4 Weeks   $1,845.00    5 CCM, 1/8 FNPT RoHS compliant
 FLR-1615A-B 4 Weeks   $2,035.00    5 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1615A-I 4 Weeks   $1,910.00    5 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1615A-I2 4 Weeks   $1,975.00    5 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1615A-V2 4 Weeks   $1,910.00    5 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1603A 4 Weeks   $1,640.00    10 CCM, 1/8 FNPT RoHS compliant
 FLR-1603A-B 4 Weeks   $1,830.00    10 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1603A-I 4 Weeks   $1,705.00    10 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1603A-I2 4 Weeks   $1,770.00    10 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1603A-V2 4 Weeks   $1,705.00    10 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1616A In Stock   $1,460.00    20 CCM, 1/8 FNPT RoHS compliant
 FLR-1616A-B 4 Weeks   $1,650.00    20 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1616A-I 4 Weeks   $1,525.00    20 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1616A-I2 4 Weeks   $1,590.00    20 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1616A-V2 4 Weeks   $1,525.00    20 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1604A 4 Weeks   $1,460.00    50 CCM, 1/8 FNPT RoHS compliant
 FLR-1604A-B 4 Weeks   $1,650.00    50 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1604A-I 4 Weeks   $1,525.00    50 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1604A-I2 4 Weeks   $1,590.00    50 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1604A-V2 4 Weeks   $1,525.00    50 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1617A 4 Weeks   $1,460.00    100 CCM, 1/8 FNPT RoHS compliant
 FLR-1617A-B 4 Weeks   $1,650.00    100 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1617A-I 4 Weeks   $1,525.00    100 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1617A-I2 4 Weeks   $1,590.00    100 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1617A-V2 4 Weeks   $1,525.00    100 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1618A 4 Weeks   $1,460.00    200 CCM, 1/8 FNPT RoHS compliant
 FLR-1618A-B 4 Weeks   $1,650.00    200 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1618A-I In Stock   $1,525.00    200 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1618A-I2 4 Weeks   $1,590.00    200 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1618A-V2 4 Weeks   $1,525.00    200 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1619A 4 Weeks   $1,460.00    500 CCM, 1/8 FNPT RoHS compliant
 FLR-1619A-B 4 Weeks   $1,650.00    500 CCM, 1/8 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1619A-I 4 Weeks   $1,525.00    500 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1619A-I2 4 Weeks   $1,590.00    500 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1619A-V2 4 Weeks   $1,525.00    500 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1620A 4 Weeks   $1,460.00    1 LPM, 1/4 FNPT RoHS compliant
 FLR-1620A-B 4 Weeks   $1,650.00    1 LPM, 1/4 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1620A-I 4 Weeks   $1,525.00    1 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1620A-I2 4 Weeks   $1,590.00    1 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1620A-V2 4 Weeks   $1,525.00    1 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1605A 4 Weeks   $1,460.00    2 LPM, 1/4 FNPT RoHS compliant
 FLR-1605A-B 4 Weeks   $1,650.00    2 LPM, 1/4 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1605A-I 4 Weeks   $1,525.00    2 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1605A-I2 4 Weeks   $1,590.00    2 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1605A-V2 4 Weeks   $1,525.00    2 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1606A In Stock   $1,750.00    5 LPM, 1/4 FNPT RoHS compliant
 FLR-1606A-B 4 Weeks   $1,940.00    5 LPM, 1/4 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1606A-I 4 Weeks   $1,815.00    5 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1606A-I2 4 Weeks   $1,880.00    5 LPM, 1/4 FNPT, two 4 to 20 mA RoHS compliant
 FLR-1606A-V2 4 Weeks   $1,815.00    5 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliant
 FLR-1607A 4 Weeks   $2,155.00    10 LPM, 1/4 FNPT RoHS compliant
 FLR-1607A-B 4 Weeks   $2,350.00    10 LPM, 1/4 FNPT, portable version †† RoHS compliancy undetermined
 FLR-1607A-I 4 Weeks   $2,220.00    10 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
 FLR-1607A-I2 4 Weeks   $2,290.00    10 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliant
 FLR-1607A-V2 4 Weeks   $2,220.00    10 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliant
 Water Flow Controller (Min ΔP = 5 psig)
 FLV-4615A 4 Weeks   $2,145.00    5 CCM, 1/8 FNPT RoHS compliancy undetermined
 FLV-4615A-I 4 Weeks   $2,210.00    5 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4615A-I2 4 Weeks   $2,275.00    5 CCM, 1/8 FNPT, two 4 to 20 mA ouput RoHS compliancy undetermined
 FLV-4615A-V2 4 Weeks   $2,210.00    5 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 FLV-4603A 4 Weeks   $2,145.00    10 CCM, 1/8 FNPT RoHS compliancy undetermined
 FLV-4603A-I 4 Weeks   $2,210.00    10 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4603A-I2 4 Weeks   $2,275.00    10 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliancy undetermined
 FLV-4603A-V2 4 Weeks   $2,210.00    10 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 FLV-4616A 4 Weeks   $2,145.00    20 CCM, 1/8 FNPT RoHS compliancy undetermined
 FLV-4616A-I 4 Weeks   $2,210.00    20 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4616A-I2 4 Weeks   $2,275.00    20 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliancy undetermined
 FLV-4616A-V2 4 Weeks   $2,145.00    20 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 FLV-4604A 4 Weeks   $2,025.00    50 CCM, 1/8 FNPT RoHS compliant
 FLV-4604A-I 4 Weeks   $2,090.00    50 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLV-4604A-I2 4 Weeks   $2,155.00    50 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLV-4604A-V2 4 Weeks   $2,090.00    50 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLV-4617A 4 Weeks   $2,025.00    100 CCM, 1/8 FNPT RoHS compliant
 FLV-4617A-I 4 Weeks   $2,090.00    100 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLV-4617A-I2 4 Weeks   $2,155.00    100 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLV-4617A-V2 4 Weeks   $2,090.00    100 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLV-4618A 4 Weeks   $2,025.00    200 CCM, 1/8 FNPT RoHS compliant
 FLV-4618A-I 4 Weeks   $2,090.00    200 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLV-4618A-I2 4 Weeks   $2,155.00    200 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLV-4618A-V2 4 Weeks   $2,090.00    200 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLV-4619A 4 Weeks   $2,025.00    500 CCM, 1/8 FNPT RoHS compliant
 FLV-4619A-I 4 Weeks   $2,090.00    500 CCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
 FLV-4619A-I2 4 Weeks   $2,155.00    500 CCM, 1/8 FNPT, two 4 to 20 mA output RoHS compliant
 FLV-4619A-V2 4 Weeks   $2,090.00    500 CCM, 1/8 FNPT, two 0 to 5 V output RoHS compliant
 FLV-4620A 4 Weeks   $2,385.00    1 LPM, 1/4 FNPT RoHS compliancy undetermined
 FLV-4620A-I 4 Weeks   $2,450.00    1 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4620A-I2 4 Weeks   $2,515.00    1 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliancy undetermined
 FLV-4620A-V2 4 Weeks   $2,450.00    1 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 FLV-4605A 4 Weeks   $2,385.00    2 LPM, 1/4 FNPT RoHS compliancy undetermined
 FLV-4605A-I 4 Weeks   $2,450.00    2 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4605A-I2 4 Weeks   $2,515.00    2 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliancy undetermined
 FLV-4605A-V2 4 Weeks   $2,450.00    2 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 FLV-4606A 4 Weeks   $2,385.00    5 LPM, 1/4 FNPT RoHS compliancy undetermined
 FLV-4606A-I 4 Weeks   $2,450.00    5 LPM, 1/4 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 FLV-4606A-I2 4 Weeks   $2,515.00    5 LPM, 1/4 FNPT, two 4 to 20 mA output RoHS compliancy undetermined
 FLV-4606A-V2 4 Weeks   $2,450.00    5 LPM, 1/4 FNPT, two 0 to 5 V output RoHS compliancy undetermined
 Accessories for FLR-1600/FLV-4600 Series
 FMA1600-BP In Stock   $225.00    Battery Pack for portable use with water meter only (not for use with -B portable meters) RoHS compliant
 FMA1600-C1 In Stock   $42.00    Replacement 8-pin male Mini-Din connector cable, singled ended, 1.83M (6') RoHS compliant
 FMA1600-C1-25 FT In Stock   $77.00    8-pin male Mini-Din connector cable, singled ended, 7.62M (25') RoHS compliant
 FMA1600-C2 In Stock   $49.00    8-pin male Mini-Din connector cable, double ended, 1.83M (6') RoHS compliant
 FMA1600-C2-25 FT In Stock   $91.00    8-pin male Mini-Din connector cable, double ended, 7.62M (25') RoHS compliancy undetermined
 FMA1600-C3 In Stock   $49.00    8-pin male Mini-Din to DB9 female adapter, 1.83M (6') RoHS compliant
 FMA1600-CRA In Stock   $49.00    8-pin male right-angle Mini-Din cable, singled ended, 7.83M (6') RoHS compliancy undetermined
 FMA1600-MDB In Stock   $260.00    Multi-drop box RoHS compliancy undetermined
 FMA1600-PSU In Stock   $80.00    Universal 100-240 VAC to 24 Volt DC power supply adaptor RoHS compliancy undetermined
 FTNY-K210BN In Stock   $4.00    Nylon body, tube ID 1/6" BAXB to 10-32 UNF connector RoHS compliant
 FTPP-K230NP In Stock   $4.00    Polypropylene body, tube ID 1/8" hose barb to 10-32 UNF connector RoHS compliant

 Order specific or non-standard models here!
 Reset  

All dollar amounts on this site are shown in US currency.

 Note:

Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini-DIN connector, operator's manual, and NIST certificate.

††Portable versions "-B" have an integral battery compartment and come complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini-Din connector, operator's manual, NIST certificate and 9V battery installed. Portable version is not available on models with 4 to 20 mA output.

Calibrations done at ambient (21°C/70°F) temperature only.

To replace the standard RS232 communications with RS485, add suffix "-RS485" to model number, add $120 to price.

**Optional secondary output are scaled the same as the primary output scale:
For alternate Temperature output scale, add suffix "-T" to the model number, no additional cost.
For alternate Pressure output scale, add suffix "-P" to the model number, add $175 to cost.
NOTE: Models with secondary output for pressure include optional gauge pressure sensor.

For units scaled in CFH, add suffix "-CFH" to model number, no additional cost. Specify required range in CFH.

For totalizer option, add suffix "-TOT" to model number, add 120. to the price. Please specify resolution. This is a 6-digit cvounter. Examples: For totalzing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.

For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').

(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)


 Ordering Example: (1) FLR-1601A 10-32 Thread Water Flow Meter, $2,035.00
 Part Number Builder
(1) (2) (3)
-
  
Option Descriptions
(1) Type
  Select
FLR for Water Flow Meter
FLV for Water Flow Controller
(2) Code in Part Number
  Select
1601A for code 1601A
1602A for code 1602A
1614A for code 1614A
1615A for code 1615A
1603A for code 1603A
1616A for code 1616A
1604A for code 1604A
1617A for code 1617A
1618A for code 1618A
1619A for code 1619A
1620A for code 1620A
1605A for code 1605A
1606A for code 1606A
1607A for code 1607A
4604A for code 4604A
4617A for code 4617A
4618A for code 4618A
4619A for code 4619A
(3) Output
  Select
Nothing(leave field blank)
-I for 4-20 mA output
-I2 for second channel output of 4-20mA
-V2 for second channel output of 0-5 Volts
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
FTB9500 Series FTB9500 Series:
Low Flow Turbine Meters
FLR1000 FLR1000:
Air/Water Flow Sensors With 0 to 5 Vdc Output
FT-HS, FT-ME, FT-MS, FT-BHU, FT-HT, FT-HE Series FT-HS, FT-ME, FT-MS, FT-BHU, FT-HT, FT-HE Series:
Tube Fittings
FLR2000 and FLV2000 Series FLR2000 and FLV2000 Series:
Flow meters 0.03 to 475 GPH
   
Keywords:Water Flowmeters and Controllers for Low Flow. Minimum flow is 0.01 ml/min, flowmeter, flow meter, flow measurement, very low flow, low flow, micro flow meter, laminar flow , datalogger usb electronic enclosure cooling humidity tester process flow control