Economical Gas Mass Controllers With or Without Integral Display |
| FMA5400 and FMA5500 |
|
 |
|
|
|
|
|
$
1,502.00
FMA5544
|
| |
NIST Traceable Calibration
|
| |
Reads and Controls Gas Mass Flow Without Temperature or Pressure Compensation
|
| |
Available in Economical Aluminum or Corrosion-Resistant 316 SS
|
| |
Tiltable LCD Display for Easy Reading
|
View related products - Electronic Mass Flowmeters
|
| |
|
|
|
 |
The FMA5400/5500 Series electronic gas mass flow controllers provide for controlling the flow of a wide
variety of gases from 0-10 SCCM up to 100 SLM. Utilizing heat transfer through a heated tube to measure
molecular gas flowrate, the FMA5400/5500 provides measurement of direct gas mass flowrate, without the
need to compensate for variations in gas temperature or pressure (within stated limits). They are
available in an economical aluminum/brass construction for typical gas flows and a 316 SS construction
for applications requiring more corrosion resistance. The FMA5400 series without integral display is
supplied with both an analog 0-5 Vdc and 4 to 20 mA output for remote monitoring; the FMA5500 series
has both an integral 3-1/2 digit display and analog output. The display is tiltable over 90 degrees for
viewing convenience. The display is calibrated standard to read out directly in SCCM or SLM for nitrogen
(other gas calibrations available on special order).
The FMA5400/5500 mass flow controllers feature a built-in normally-closed electromagnetic valve for
maintaining a constant flowrate regardless of variations in inlet or outlet pressures. The setpoint is
controlled either locally via a potentiometer accessible through an access window in the case or
remotely via an analog 0-5 Vdc or 4-20 mA signal (field selectable). The FMA5400/5500 series require
12 to 15 Vdc power @ 800 mA maximum, which can be supplied by the FMA545PW wall plug-in socket power
supply (24 Vdc power input @ 650 mA is optionally available). The electronics are reverse polarity
protected and have a resettable fuse. Model number FMA545C (supplied separately) provides a mating
15-pin “D” connector with 8 feet of shielded cable for accessing the analog output signals and power
input connections. The LCD supplied with the FMA5500 series is connected to the lower electronics
via a modular plug. The LCD can be remotely located by purchasing an FMA18RC remote cable assembly–you
must then build your own assembly for panel mounting the LCD.
Range Table
| Code |
SCCM |
| 02 | 0-10 |
| 04 | 0-20 |
| 06 | 0-50 |
| 08 | 0-100 |
| 10 | 0-200 |
| 12 | 0-500 |
|
| Code |
SLM |
| 14 | 0-1 |
| 16 | 0-2 |
| 18 | 0-5 |
| 20 | 0-10 |
| 22 | 0-15 |
|
| Code |
SLM |
| 24 | 0-20 |
| 26 | 0-30 |
| 28 | 0-50 |
| 40 | 0-60 |
| 41 | 0-80 |
|
| Code |
SLM |
| 42 | 0-100 |
| 43 | 0-200 |
| 44 | 0-500 |
| 45 | 0-1000 |
|
SPECIFICATIONS
Accuracy: ±1.5% FS, including linearity over 15 to 25°C (59 to 77°F) and
0.7 to 4.2 kg/cm² (10 to 60 psia) ±3% FS for units ≥ 100 SLM from o to 20% of range.
Repeatability: ±0.5% of full scale
Temp Coefficient: 0.15% FS/°C
Pressure Coefficient: 0.01% FS per psi (0.07 bar)
Maximum Pressure Drop: 50 psid
Response Time: 5 seconds to within ±2% of set flow rate over 25 to 100% FS
Max Gas Pressure: 35 kg/cm2 gage (500 psig); 1.76 kg/cm (25 psig) optimum
Gas and Ambient Temp: 5 to 50°C (41 to 122°F)
Leak Integrity: 1 x 10-7 cc/sec of He max to outside environment
Materials in Fluid Contact:
Aluminum Models: Anodized aluminum, 316 SS, brass and FKM O-rings
Stainless Steel Models: 316 SS and FKM O-rings
Output Signal:
Linear 0 to 5 Vdc: 1000 Ω minimum load
4 to 20 mA: 50 to 500 Ω loop resistance, ±20 mV max noise
Transducer Power: 12 Vdc @ 800 mA standard; 24 Vdc @ 650 mA optional
Turndown Ratio: 50:1
Shipping Weight: 1.8 kg (4 lb)
Compliance: EN55011 class 1, class B; EN50082-1
Attitude Sensitivity: With horizontal flow path, no shift in calibration up to +20 degree pitch
Gas Relative Humidity: 0 to 70% RH
Min Pressure Drop
| SLM |
≤9 |
10-30 |
50 |
60-100 |
200 |
500 |
1000 |
| psid |
1.1 |
3.9 |
8 |
18.9 |
10 |
12 |
15 |
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with NIST certificate, compression fittings, and operator's manual. Power supplies sold separately.
Flow ranges specified are for nitrogen or air at 20 psig inlet (up to 50 SLM0 or 25 psig inlet (60 to 100 SLM units) and 0 psig outlet. when used with other gasses, a multiplication factor is used to determine the flow rate, and the digital display must be rescaled in the field.
To request a custom calibration add the gas abbreviation and inlet pressure/outlet pressure as a suffix to the model number.
Calibrations done at ambient (20C/70F) temperature only.
For 316SS add suffix "ST" to the part number, consult Omega Flow Engineering for cost.
For units powered by 24 Vdc, add suffix “-24VDC” to model number, no additional cost.
For oxygen cleaned units, add suffix "-O2CLEAN" to the model number, add $125 to the price.
Ordering Example: (1) FMA5506ST 316SS Mass Flow Controller 50 sccm, $1,034.00, plus (1) FMA545PW Power Suppy for 110Vac, $60.00, $1,034.00 + 60.00 = $1,094.00
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Display
|
| |
Select 54 for without display 55 for with display
|
(2)
|
Range Code(see table above)
|
| |
Select 02 for code 02 04 for code 04 06 for code 06 08 for code 08 10 for code 10 12 for code 12 14 for code 14 16 for code 16 18 for code 18 20 for code 20 22 for code 22 24 for code 24 26 for code 26 28 for code 28 40 for code 40 41 for code 41 42 for code 42
|
(3)
|
Body
|
| |
Select Nothing(leave field blank) for aluminum/brass body ST for 316 SS body
|
|