Versatile Electronic Mass Flowmeters Now Available With Rugged 316SS Flow Body |
| FMA-5600and FMA-5700 |
|
 |
|
|
|
|
|
|
|
| |
Unique Built-in Digital Display for Direct Readout in SCCM and SLM Units (Model FMA-5600 Series)
|
| |
13 Flow Ranges, from 0 to 10 SCCM to 0 to 40 SLM
|
| |
Excellent Performance, ±1.5% Accuracy of Full Scale, 0.5% Repeatability, and Time Response of 2 Seconds
|
| |
Nist Traceable Certificate Included (no points)
|
View related products - Electronic Mass Flowmeters
|
| |
|
|
|
 |
FMA-5000 Series Electronic Mass Flowmeters provide high performance, versatility and state of
the art design in one compact package. The FMA-5000 Series measures the mass flowrate of
gases in 13 ranges from 0 to 10 SCCM (Standard Cubic Centimeters per Minute), to 0 to 50 SLM
(Standard Liters per Minute). For the complete listing of ranges, refer to the Flow Range Table on page
D-28. Accuracy is 1.5% of full scale over a wide temperature and pressure range. Time response is 2
seconds to within 2% of final flow. These unique flowmeters are available with or without digital
display. An optional power supply can be purchased separately.
A major application for the FMA-5600 is in the replacement of rotameters. Their analog output,
integral/remote digital display, insensitivity to temperature and pressure variations and low cost make
them ideal substitutes for rotameters. In fact, they can also be used to calibrate
rotameters. Other applications include chemical and food processing, research and development, gas
chromatography, and leak and filter testing, to name a few.
Additional design features include a 31/2-digit LCD display (FMA-5600 Models) of the mass flowrates
directly in SCCM or SLM. (Other gases available by special order.) The display is tiltable over 180° for
easy viewing, and can be ordered with 25 feet of cable for remote surface mounting. The FMA-5600
and FMA-5700 Series require a 12 to 15 Vdc external power source provided by the Model FMA-PST
Power Supply Accessory. A 0 to 5 Vdc (standard), or 4 to 20 mA (optional) output signal linearly
proportional to gas mass flowrate is provided for recording, datalogging, or control. A 9-pin “D” subconnector
for the output signal, input power, and remote display drive is supplied with its mating connector for all
FMA-5000 Series units.
All wetted surfaces are constructed of corrosion resistant glass-filled Nylon 66 plastic, 316SS, and FKM O-rings.
Flow Range† Code Table (Insert Code into Model Number)
| Code | SCCM | Code | SLM |
| 01†† | 0-10 | 07 | 0-1 |
| 2 | 0-20 | 08 | 0-2 |
| 3 | 0-50 | 09 | 0-5 |
| 4 | 0-100 | 10 | 0-10 |
| 5 | 0-200 | 11 | 0-20 |
| 6 | 0-500 | 12 | 0-30 |
| | | 13 | 0-40 |
† Flow ranges specified are for Nitrogen or Air. When used for other gases, a multiplication factor is used to determine
the flowrate, and the digital display must be rescaled in the field.
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with NIST traceable cert and operator's manual.
Calibrations done at ambient temperature only.
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -