Flow Indicators and Totalizers With Analog & Digital Displays |
| FPM-5500 |
|
 |
|
|
|
 |
The FPM-5500 flow monitor is a feature-packed process monitor covering the widest possible spectrum of
applications. Dual totalizers are calibrated independently of the digital analog flowrate. Reset one
totalizer remotely from 100 feet away. Expand the communication range of the system by connecting
peripheral equipment to the isolated frequency out, the totalizer pulse output, the alarm contact
outputs, or the 4 to 20 mA current output. Packaged in a slim-line housing with NEMA-4X shatter-
resistant front panel, the FPM-5500 is the most sophisticated analog monitor available.
SPECIFICATIONS
Accuracy: ±0.5% of reading
Repeatability: ±0.2% of reading
Input: Optically isolated
Input Range: 0.5 Hz to 10 kHz
Display: NEMA 4X (IP66)
Update Rate: 1 s
Totalizers: 8-digit resettable with security option 8-digit non-resettable
Environmental:
Operating temperature: -10 to 55°C (14 to 131°F)
Relative Humidity: 0 to 95%, non-condensing
Alarm Contacts: High/low pulse programmable
Hysteresis: 2% of range (fixed)
2 SPDT Relays: 5 A @ 30 Vdc; 5 A @ 125 Vac; 3 A @ 250 Vac
Current Output: 4 to 20 mA, non-isolated, internally powered
Update Rate: <100 ms
Loop Impedance: 350Ω max @ 12V, 950Ω max @ 24V
Accuracy: ±0.1%
Frequency Output and Totalizer Pulse Output: Open-collector transistor, optically isolated,
5 mA max sink
Totalizer Reset: Front keypad or external contact closure; 30 m (100') max cable length
Dimensions: 97 L x 97 W x 76 mm D (3.8 x 3.8 x 3.0") 92 mm² Cutout
Compatible Sensors: FP-5300/5100, FP-5200, FP-6000, and FP-5600 (see related links below)
|
| |
 |
|
 |
|
 |