FTB-939
|
| |
±1% of Reading Accuracy
|
| |
Ball Bearing Design for Economy
|
| |
440C Bearing Retainers for Durability
|
| |
Ball Bearings Field Replaceable Without Loss of Calibration
|
| |
Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
|
| |
NIST Certificate Supplied Standard
|
View related products - Turbine and Paddle Wheel Flowmeters
|
| |
|
|
|
 |
The OMEGA® FTB-930 & FTB-940 Series turbine meters have male NPT end fittings for easy connections. They are suitable for use with gases with a minimum density of 0.025 lb/ft 3 (air at STP is 0.0752 lb/ft 3 ).These units come supplied with a mating 2-wire connector and can be supplied with integrally mounted FLSC-60 Series signal conditioners to provide 4-20 mA, 0-5 V, or amplified pulse outputs. These turbine gas meters are intended for clean service only; where there is any doubt about the fluid, strainers are recommended.
OMEGA® precision turbine gas
flowmeters are designed to measure
actual cubic feet or actual volume
passing through the meter. Before
sizing a flowmeter, it is necessary to
convert flow units (i.e., SCFM, LPM,
etc.) to actual units. To convert to
actual measured volume (ACFM)
from standard volume (SCFM), use
the following formula:
| ACFM | = | SCFM x 14.7/Pa x Ta/530 |
| where: |
| ACFM | = | Actual cubic feet per minute of measured gas flow |
| SCFM | = | Standard cubic feet per minute gas flow |
| Pa | = | Operating pressure (psia) in = (psig + 14.7) |
| Ta | = | Temperature in degrees, Rankine = (°F + 460) |
SPECIFICATIONS
Accuracy: ±1.0% of reading
Repeatability: ±0.25%
Materials of Construction:
Body: 304/316 stainless steel
Rotor: 17-4 PH SS
Bearings: 440C stainless steel
Output: 30 mV p-p sinewave min.
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual and NIST Certificate for air.
To order turbine meters with integral signal conditioners, specify model as a system such as : SYS/FTB-932/FLSC-62A. Omega will scale the signal conditioner with the appropriate calibration information from the turbine meter specified.
No other calibrations are available.
Compatible Meters: DPF701, DPF402, DPF70 with FLSC-AMP, DPF10, DPF500, FC20, 21, 22
Contact Flow Engineering Dept
Ordering Example: (1) FTB-932 0.75-5 Max Linear Range (ACFM); 1/2 End Connections MNPT (in), $1,115.00, plus (1) DPF701 1/8 DIN Panel Meter for Rate or Totalization, $280.00, $1,115.00 + 280.00 = $1,395.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Manual, Related Products
|
 |
 |
 |
 |
 |
 |
|
Product Manual
|
|
Download
FTB-900/FTB9500 Series - Precision Turbine Flowmeters
|
|
Download
FLSC-64 - Pulse Amplifier
|
|
Download
FLSC-62A - Signal Conditioner
|
|
Download
FLSC-61 - 3-Wire Analog Transmitter
|
|
Related Products
|
 |
FLSC-60:
|
|
Direct Mounting Signal Conditioners for FTB-930/940 Series Turbine Flowmeters
|
 |
 |
|
|
 |
DPF75:
|
|
Ratemeters, Totalizers and Batch Controllers for Frequency Inputs
|
 |
 |
|
|
|
|
 |
 |
|
|