Environmental/Process Air Transmitters |
| HX80 Series |
|
 |
|
|
|
 |
HX80 Series is a family of humidity
probes that offers a variety of
measurement parameters
with precision accuracy: RH,
temperature, dew point, pressure
(psia), ppmv, ppmw, gr/lbs, etc.
The probe is easily adaptable for
most applications including high
temperature and high pressure
conditions.
The HX85 is a humidity/temperature
stainless steel probe with a
stainless steel sinter filter, RS232
and 0 to 10 Vdc outputs, RH
measurement range is 5 to
95% with an accuracy of ±1%,
operating temperature -20 to 75ºC
(-4 to 167ºF), dew point range
30 to -60ºC (86 to -76ºF), default
outputs: RH, temperature and
dew point.
The HXB85 is a humidity/temperature/barometric pressure
stainless steel probe with a
stainless steel sinter filter, RS232
and 0 to 10 Vdc outputs, RH
measurement range is 5 to 95%
with an accuracy of ±1%,
pressure range is (barometric
pressure, 0 to 1100 MB, operating
temperature -20 to 75ºC
(-4 to 167ºF), default outputs:
RH, temperature and pressure.
The HXP85 is a humidity/temperature/high pressure stainless
steel probe with a stainless steel
sinter filter, RS232 and 0 to 10 Vdc
outputs, RH measurement range is
5 to 95% with an accuracy of ±1%,
pressure range is 0 to 200 psia,
operating temperature -20 to 75ºC
(-4 to 167ºF), default outputs: RH,
temperature and pressure.
The HX86 is a remote [1.8 m (6')
cable] humidity/high temperature
stainless steel probe with a
stainless steel sinter filter, RS232
and 4 to 20 mA outputs, RH
measurement range is 5 to 95%
with an accuracy of ±1%, operating
temperature -20 to 115ºC
(-4 to 239ºF), default outputs:
RH, temperature and dew point,
display included.
HXB86 is a remote [1.8 m (6')
cable] humidity/high temperature/
barometric pressure stainless steel
probe with a stainless steel sinter
filter, RS232 and 4-20 mA
outputs, RH measurement range is 5 to 95% with an accuracy of ±1%,
pressure range is (barometric
pressure, 0 to 1100 MB, operating
temperature -20 to 115ºC
(-4 to 239ºF), default outputs:
RH, temperature and pressure,
display included.
The HX86N is a remote [1.8 m (6')
cable] humidity/high temperature
stainless steel probe with a
stainless steel sinter filter, RS232
and 0 to 10 Vdc outputs, RH
measurement range is 5 to 95%
with an accuracy of ±1%, operating
temperature -20 to 115ºC
(-4 to 239ºF), default outputs:
RH, temperature and dew point.
COMMON SPECIFICATIONS
RH Accuracy: ±1% RH
Temp Accuracy: ±0.5ºC
Electrical Outputs
Units with Probe only (HX85, HXB85, HXP85,HX86N): 0 to 10 Vdc (x3) @ 10 mA max
Temp Measurement Range: -20 to 75ºC (-4 to 167ºF)
RH Measurement Range: 5 to 95%
Units with Probe and Remote Electronics Module :
Temp Measurement Range: -20 to 115ºC (-4 to 239ºF)
Current Outputs (X 3): 4 to 20 mA into 500 O max
Alarm Relay (x2): Form A (SPST, NO) rated at 3 A/250 Vac
Serial Output (All Units): RS232C to DTE device, 19.2 kilobaud, 8 bits data, 1 stop bit, no parity; RS232C (bi-directional)
Power Requirements: 18 to 30 Vdc unregulated, 50 mA max
Dimensions:
Sensor: 19 x 203 mm (3/4 x 8")
Cable Length: 1.8 m (6'); consult factory for longer lengths
Electronics Module
Outside Dimensions: 13 H x 9.4 W x 5.6 cm D(5.1 x 3.7 x 2.2")
Mounting Centers: 11.5 X 7.9 cm (4.53 x 3.11")
Sensor Pressure Rating: 200 psia max
Sensor Sintered Filter: 40 microns
Material: Stainless steel |
|
SERIES SPECIFICATIONS
HX85 (Sensor Only)
Measured Parameters: RH/temp
Output Information: RH, temp, DP
Electrical Outputs: 0 to 10 Vdc (x3)
HXB85 (Sensor Only)
Measured Parameters: RH/temp/barometric pressure
Pressure Measurement Range: 0 to 1100 MB
Pressure Accuracy: ±5 MB
Output Information: RH, temp, pressure
Electrical Outputs: 0 to 10 Vdc (x3)
HXP85 (Sensor Only)
Measured Parameters: RH/temp/high pressure
Pressure Measurement Range: 0 to 200 psia
Pressure Accuracy: ±0.75 psi
Output Information: RH, temp, pressure
Electrical Outputs: 0 to 10 Vdc (x3)
HX86 (Sensor with Electronics Module)
Measured Parameters: RH/high temp
Output Information: RH, temp, DP
Electrical Outputs: 4 to 20 mA (x3)
Alarm Relays: (x2)
Digital Display: LCD, 2-line
HXB86 (Sensor with Electronics Module)
Measured Parameters: RH/high temp/barometric pressure
Pressure Measurement Range:0 to 1100 MB
Pressure Accuracy: ±5 MB
Output Information: RH, temp, pressure
Electrical Outputs: 4 to 20 mA (x3)
Alarm Relays: (x2)
Digital Display: LCD, 2-line
HX86N (Sensor Only)
Measured Parameters: RH/high temp
Output Information: RH, temp, DP
Electrical Outputs: 0 to 10 Vdc (x3)
|
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.