Canister Style Compression Load Cells, Multi-Column Design |
| LC1288 - Discontinued |
|
 |
|
|
Canister Style Compression Load Cells, Multi-Column Design
 |
| Click for larger image. |
|
|
|
|
|
|
 |
SPECIFICATIONS Agency Approvals: NTEP: III 5,000 Multiple NTEP: IIIL 10,000 Multiple OIML: R60 3,000 Multiple Excitation: 5 to 20 Vdc recommended; 25 Vdc maximum Full Scale Output: 2 mV/V ±0.25% Calibration: (Compression) NIST Traceable Combined Error: 0.03% FS Linearity: 0.03% FS Hysteresis: 0.03% FS Repeatability: 0.02% FS Creep Error: 0.03% FS in 20 min Thermal Effects: Zero 0.0015% FS/°F Span 0.0008% Rdg/°F Zero Balance: 0.01% FS Insulation Resistance: 1000 MOhms at 50 Vdc Operating Temp Range: -18 to 65°C (0 to 150°F) Compensated Temp Range: -10 to 40°C (14 to 104°F) Ultimate Overload: 300% of rated capacity Input Resistance: 450 ±4.5 Ohms Output Resistance: 480 ±4.8 Ohms Safe Side Load: 30% of rated capacity Safe Overload: 150% of rated capacity Ultimate Overload: 400% of rated capacity Sealing: Meets IP66/67 standards Material: Welded Stainless Steel Electrical: 35 ft (10.7 m) 4-Conductor Cable; 22 AWG Shielded & Jacketed
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Related Products
|
 |
 |
 |
 |
 |
 |
|
Related Products
|
 |
DP41-W:
|
|
Legal-For-Trade Weigh Scale Panel Meters, NTEP Approved Per HB44
|
 |
 |
|
 |
SBJ2:
|
|
Summing Junction Boxes NEMA-4X Enclosure
|
 |
 |
|
|
|
 |
 |
|
|