The LC501 is also available in metric configurations, with ranges from 0-25 to 0-10,000 kgf.
Please see the LCM501 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS: Excitation: 10 Vdc, 15 Vdc max Output: 3 mV/V ±0.25% 5-Point Calibrated (in Compression): 0%, 50%, 100%, 50%, 0% (includes 59 kOhm shunt cal data) Linearity: ±0.03% FSO Hysteresis: ±0.02% FSO Repeatability: ±0.02% FSO Zero Balance: ±1% FSO Agency Approvals: FM Intrinsically Safe IS/I.II.III/1/CDEFG Operating Temp Range: -34 to 82°C (-30 to 180°F) Compensated Temp Range: 16 to 71°C (60 to 160°F) Thermal Effects: Zero: ±0.001% FSO/oF Span: ±0.001% FSO/oF Safe Overload: 150% of capacity Ultimate Overload: 300% of capacity Input Resistance: 360 Ω minimum Output Resistance: 350 ±10 Ω FS Deflection: 0.5 mm (0.02") typical Construction: 17-4 PH stainless steel, >20,000 lb, high-alloy steel Electrical: 4-conductor shielded PVC cable LC 501: 4.8 m (15') Mating Connector: PT06F10-6S (not included)
† All dollar amounts on this site are shown in US currency.
Note: To Order Load Cells with a Bendix connector, specify Model LC511, same price. Ordering Example: (1) PT06F10-6S Mating Connector, (1) LC501-5K 5,000 lb capacity load cell = $376.5