Tall Through-Hole Bolt Load Cells, 1.50-3.00" Diameter |
| LC8151 |
|
 |
|
|
Tall Through-Hole Load Cells, 1.50-3.00" Diameter
 |
| Click for larger image. |
|
|
|
|
|
|
 |
SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ±2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C
Span: ±0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 Ω minimum
Output Resistance: 350 ±5 Ω
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) LC8151-500-3K is a 3,000 lb capacity load cell with 1.50" O.D. and 0.50" I.D., $635.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |