High Accuracy Low Profile Compression Load Cell, Metric, 0-10 kgF to 0-5,000 kgF, For Industrial Weighing Applications |
| LCM401 and LCM411 Series |
|
 |
|
|
|
|
|
 |
The LCM401 is also available in standard configurations, with 0-50 to 0-400,000 lb ranges.
Please see the LC401 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS Excitation: 10 Vdc (15 Vdc max) Output: 3 mV/V ±0.25% Linearity: >1000 kg: 0.10% FSO; <2000 kg: 0.13% FSO Hysteresis: >1000 kg: 0.10% FSO; <2000 kg: 0.12 % FSO Repeatability: 0.05% FSO Zero Balance: ±1% FSO Agency Approval: FM Intrinsically Safe IS/I.II.III/1/CDEFG Standard Operating Temp Range: -54 to 107°C (-65 to 225°F) Compensated Temp Range: 16 to 71°C (60 to 160°F) Thermal Effects: Zero: 0.0045% FSO/°C Span: 0.0063% FSO/°C Safe Overload: 150% FS Ultimate Overload: 300% FS Bridge Resistance: 350 ±5 Ohms Deflection: 0.025 to 0.076 mm typical Construction: 17-4 pH Stainless Steel Electrical Connection: LCM401: 4.6 m (15 ft) 4-Conductor shielded cable LCM411: PTIH-10-6P Twist lock connector (or equivalent) Mating Connector: (not included) PT06F-10-6S $26.50
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) LCM401-500 is a 500 kgF capacity cable style load cell, = $595
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |