The LCM402 and LCM412 are also available in standard configurations, with 0-50 to 0-750,000 lb ranges and standard threads.
Please see the LC402 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ±0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ±1% FSO
Agency Approval: FM Intrinsically Safe IS/I.II.III/1/CDEFG
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
ranges ≤400,000 lb: 300% of Capacity
ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ±10 Ω
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes with 5-point calibration at 0%, 50%, 100%, 50%, 0% of full scale in compression. Units ordered with optional tension plate calibrated in tension.
Ordering Example: (1) LCM412-500 low profile 0 to 500 kgF capacity connector style load cell, (1) PT06F10-6S mating connector = $756.5
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |