Non-Contact Ultrasonic Level Controller |
| LVCN700 Series |
|
 |
|
|
Non-Contact Ultrasonic Level Controller
 |
| Click for larger image. |
|
|
$
595.00
LVCN704
|
| |
Target Calibration Via Push Buttons
|
| |
7.6 cm (3") Beam Diameter for Restricted Space Applications
|
| |
5 cm (2") Dead Band Optimizes Filling Capacity of Small Vessels
|
| |
Fail-Safe Intelligence with Diagnostic Feedback for Easy Troubleshooting
|
| |
PC/ABS Enclosure Rated NEMA 4X (IP65) with Rugged PVDF Transducer
|
View related products - Level Measurement
|
| |
|
|
|
 |
The LVCN700 Series general
purpose ultrasonic switch provides
non-contact level detection from up
to 8 m (26') away, and has 3 relay
outputs. Each relay can be
configured on a single setpoint
alarm, 2 latched setpoints for
automatic fill or empty including
lead-lag, or 2 independent setpoints
for out-of-bounds alarms. In
addition, relays 1 and 2 can be
interlocked for relay alternation or
duplex operation. The switch is well
suited for a broad range of
corrosive, waste and slurry-type
media, and is broadly selected for
atmospheric day tank, pump lift
station and waste sump applications.
SPECIFICATIONS
Range:
LVCN704: 5 cm to 1.2 m (2" to 4')
LVCN709: 10 cm to 3 m (4" to 9.8')
LVCN716: 10 cm to 5 m (4" to 16.4')
LVCN726: 20 cm to 8 m (8" to 26.2')
Repeatability: 6 mm (0.25")
Adjustability: Over entire range
Hysterysis (Single Setpoint):
LVCN704/709: 1.3 cm (0.5")
LVCN716/726: 2.5 cm (1")
Beam Width:
LVCN704/709: 5.1 cm (2") dia.
LVCN716/726: 7.6 cm (3") dia.
Deadband:
LVCN704: 5 cm (2")
LVCN709/716: 10 cm (4")
LVCN726: 20 cm (8")
LED Indication: Power, relay and echo status
Calibration: Target, pushbutton
Memory: Non-volatile
Supply Voltage: 95 to 250 Vac,
-DC Model Numbers: 12 to 28 Vdc
Consumption: 20 W max, AC power, 100 mA @ 24 Vdc
Contact Type: (3) SPDT relays
Contact Rating: 60 VA
Contact Logic:
Single Point: Alarm
2-Point: Latching or out-of-bounds alarms
Relay Interlock: Relays 1 and 2 only; alternation or duplexing
Contact Fail-Safety: De-energizes during echo signal loss
Process Temp: -20 to 60°C (-4 to 140°F)
Temperature Comp: Automatic
Electronics Temperature: -40 to 71°C (-40 to 160°F)
Pressure: 30 psi (2 bar) @ 25°C, derated @ 1.667 psi (0.113 bar) per °C above 25°C
Enclosure Rating: NEMA 4X (IP65)
Enclosure Vent: Watertight membrane
Enclosure Material: PC/ABS FR
Transducer Material: PVDF
Process Mount:
LVCN704/709: 1 NPT or 1" G
LVCN716/726: 2 NPT or 2" G
Mountable Gasket: FKM
Conduit Entrance: Dual, ½ NPT
Classification: General purpose
CE Compliance: EN 61326 EMC (pending) EN 61010 safety
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual.
Ordering Example: (1) LVCN704 Level switch—1.2 m (4') range, 1 NPT, $595
|
|
 |
|
 |
|  |
|
Back to top
|
|