Cryogenic Temperature Liquid Level Switches |
| LVUC11 and LVUC12 Series |
|
 |
|
|
Cryogenic Temperature Liquid Level Switches
 |
| Click for larger image. |
|
|
|
|
| |
1000: 1 Wet to Dry Ratio with Standard
|
| |
Miniaturized Encapsulated Electronics
|
| |
No Calibration or Special Installation Requirements
|
| |
Cryogenic Temperature Down to -184°C (-300°F)
|
View related products - Level Measurement
|
| |
|
|
|
 |
The LVUC10 liquid level switch is the ideal
solution to a host of liquid level sensing
applications at cryogenic temperatures.
It uses proven ultrasonic technology to
operate in virtually any liquid, regardless
of viscosity or aeration. Its small size and
standard ¾NPT mounting make it the
perfect choice for new or existing
applications.
The LVUC10 consists of a 316 SS sensor
and an integral miniaturized, encapsulated
electronic control unit which is mounted in
a cast aluminum, explosion-proof,
watertight enclosure. It can be either
integral or remotely mounted.
SPECIFICATIONS
Repeatability: 2 mm typical
Delay (On): 0.5 seconds (typical) varies with cryogenic temperature
Input Power:
Standard: 115 Vac
Optional: 230 Vac 50/60 Hz, 12 or 24 Vdc
Outputs: 10A DPDT relay standard, 8.0 ± 1.0mA-dry, 20.0 ± 1.0 mA-wet
Housing: NEMA 7 watertight, explosion proof enclosure. Cast Aluminum Class l, Group C & D, Class II, Group E, F, & G; and Class lll, Division 1 & 2
Housing Dimensions: 13 mm (5.17") H x 95.3 mm (3.75") diameter, conduit entry ¾NPT
Sensor Material: Epoxy tip with 316SS hermetically sealed fitting
Sensor Cable Length: 3 m (10') standard
Sensor Dimensions: 57.1 mm (2.25") L, 12.7 mm (0.5") outside diameter, 9.5 mm (0.375") tip diameter, 3 mm (0.125") gap width
Temperature Range:
Sensor: -240 to 71°C (-400 to 160°F)
Electronics: -29 to 77°C (-20 to 170°F)
Pressure:
Operating: Up to 68.9 bar (1000 psig)
Process Connection: ¾NPT standard
Weight: 0.45 kg (1 lb) approximate
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual.
Add “-24VDC” to model number for 24 VDC power. No additional charge Add “-230V” to model number for 230 Vac power. Add $60 to the price.
For additional sensor length (bottom of thread to tip of probe) consult OMEGA Flow Engineering.
Ordering Example: (1) LVUC11 10 A Cryogenic liquid level switch, $950
|
|
 |
|
 |
|  |
|
Back to top
|
|