LIGHTWEIGHT OIL IMMERSION HEATER With 2 Element Design With 2 Inch NPT Steel Screw Plug |
| MTO-2 Series |
|
 |
|
|
|
|
|
$
295.00
MTO-215A/120V
|
| |
Rugged Steel Sheath for Use with Lightweight Oils
|
| |
1.5 to 6 kW
|
| |
120 280, 240 or 480V. 1 Phase
|
| |
General Purpose1 NEMA-1 Rated and UL Listed Enclosure or Moisture Resistant/ Explosion Enclosure2
|
View related products - Immersion Heaters
|
| |
|
|
|
 |
Please Note: The immersion heater should be used with an approved temperature control device to assure
safe operation. See Temperature Section for our selection of process controllers.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified
personnel. See inside back cover for additional warning.

| kW |
W/in2 |
No. Htg. Elem. |
Dim. B in (cm) |
E1 General Purpose Enclosure1 |
E2 Explos. /Moist Res. Encl.2 |
| Model No. |
Wt. Ib (kg) |
Model No. |
Wt. Ib (kg) |
| 1.5 | 24 | 2 | 11 3/4(30) | MTO-215A/* | 3 (1) | MTO-215E2/* | 6 (3) |
| 2 | 24 | 2 | 17 3/4 (45) | MTO-220A/* | 4 (2) | MTO-220E2/* | 7 (3) |
| 2.5 | 26 | 2 | 19 5/8 (9) | MTO-225A/* | 4 (2) | MTO-225E2/* | 7 (3) |
| 3 | 23 | 2 | 24 7/8 (63) | MTO-230A/* | 4 (2) | MTO-230E2/* | 7 (3) |
| 4 | 23 | 2 | 32 3/4 (83) | MTO-240A/* | 6 (3) | MTO-240E2/* | 8 (4) |
| 5 | 23 | 2 | 40 1/4 (102) | MTO-250A/* | 7 (3) | MTO-250E2/* | 8 (4) |
| 6 | 23 | 2 | 47 3/4 (121) | MTO-260A/** | 7 (3) | MTO-260E2/** | 9 (4) |
/*Designate voltage, i.e., insert 120 for 120 Vac, 208 for 208 VAC, 240 for 240 Vac, or 480 for 480 Vac.
//* Designate voltage, ie., insert 208 for 208 Vac, 240 for 240 Vac, or 480 for 480 Vac.
1 Heaters with General Purpose Enclosures are UL recognized and CSA Certified.
2 Heaters with Moisture Resistant/Explosion Resistant Enclosures are CSA NRTL/C Certified.
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Caution: Explosion resistant type E2 construction refers to heater design features which provide explosion resisting containment of electrical wiring according to National Electric Code. Abnormal application or use of heaters which in excessive temperatures can create hazardous conditions which can lead to fire
Ordering Example: (1) MTO-215A/240V 1.5 kW heater powered by 240 Vac, $295.00
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Wattage
|
| |
Select 15 for 1.5 kW 20 for 2 kW 25 for 2.5 kW 30 for 3 kW 40 for 4 kW 50 for 5 kW 60 for 6 kW
|
(2)
|
Enclosure
|
| |
Select A for General Purpose Enclosure E2 for Moisture Resistant/Explosion Resistant Enclosures
|
(3)
|
Voltage
|
| |
Select 120V for 120 V 208V for 208 V 240V for 240 V 480V for 480 V
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| |
|
 |
|
|
 |
|
 |
|
Back to top
|