Oven Temperature Data Logger |
| OM-CP-THERMOVAULT |
|
 |
|
|
|
|
|
$
999.00
OM-CP-THERMOVAULT
|
| |
Single Channel Thermocouple Input
|
| |
Programmable Start Time; Immediate or Date/Time
|
| |
Miniature Size
|
| |
Record Short Thermal Profiling Events
|
View related products - Recorders
|
| |
|
|
|
 |
The OM-CP-THERMOVAULT is a
thermally insulated, battery
powered, stand-alone, datalogger
used for thermal profiling of events.
This device can be used to record
the temperature inside an oven for
later downloading to a PC.
This all-in-one compact, portable, easy to
use device will measure and record
up to 16,383 temperature
measurements. It can stand an
oven temperature of 752°F for 10
minutes when properly sealed. The
OM-CP-THERMOVAULT is a major
leap forward in both cost reduction
and performance. Its real time clock
ensures that all data is time and
date stamped. The storage medium
is nonvolatile solid state memory,
providing maximum data security
even if the battery becomes
discharged. Its small size allows it
to fit almost anywhere. Data
retrieval is simple. Plug it into an
available COM port and our easy to
use software does the rest. The
software converts your PC into a
real time strip chart recorder. Data
can be printed in graphical or
tabular format and can be exported
to a text or Microsoft file.
Specifications:
Thermocouple Connection:
Fixed 2 position screw terminal
Cold Junction Compensation:
automatic
Accuracy*: (based on internal channel
at uniform 20°C): J,K,T,E,N: ±0.5°C
R,S,B: ±2.5°C
Resolution: J,K,T,E,N: 0.1°C
R,S,B: 0.5°C
Temperature Measurement
Range:
Type J:-210 to 760°C
K:-270 to 1370°C
T:-270 to 400°C
E:-270 to 980°C
R:-50 to 1760°C
S:-50 to 1760°C
B:50 to 1820°C
N:-270 to 1300°C
Memory: 16,383 readings/channel
Recording Interval: 2 seconds
to 12 hours selectable in software
Start Time: Start time and date are
programmable through software
Power: 3.6 V lithium battery
included
Battery Life: 1 year typical
Data Format: Date and time
stamped, °C, °F, °K, °R, mV
Computer Interface: PC serial,
RS-232C COM or USB
Software: XP SP3/Vista and 7
(32-bit and 64-bit)
|
|
Operating Environment
for Internal Data Logger:
-40 to +80°C (-40 to 176°F)
0 to 95% RH non-condensing
Operating Environment for
OM-CP-THERMOVAULT System:
-40 to +400°C (-40 to 752°F)
0 to 95% RH non-condensing
Temperature Versus Logger Duration Time
Ambient Temp °C (°F) | Max Duration* in Minutes |
| 100 (212) | 52 |
| 150 (302) | 30 |
| 200 (392) | 22 |
| 250 (482) | 17 |
| 260 (500) | 16 |
| 300 (572) | 15 |
| 350 (662) | 12 |
| 400 (752) | 10 |
*Assuming logger box is inititally at 25°C
Dimensions:
76 H x 153 L x 102 mm D
(3 x 6 x 4")
Weight: 0.9 kg (2 lbs)
Enclosure (Thermal Box):
Thermal insulators encased
in stainless steel
Enclosure (Logger): ABS Plastic
|
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Operator's manual, battery and USB interface cable are included with the OM-CP-IFC200 Windows software (software is required to operate the datalogger and sold separately).
Ordering Example: (1) OM-CP-THERMOVAULT-CERT Oven temperature datalogger with NIST calibration certificate, $1,059.00, plus (1) OM-CP-IFC200 Windows software and 3.7 m (12') USB interface cable, $129.00, $1,059.00 + 129.00 = $1,188.00
|
|
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Manual
|
 |
 |
 |
 |
 |
 |
|
Product Manual
|
|
Download
OM-CP Series - Data Logger and Software User Guide
|
|
Download
OM-CP Series - Data Logger Quickstart Guide
|
|
|
 |
 |
|
|