Precision I/R Thermocouples |
| OS36-10-K Series |
|
 |
|
|
|
 |
The OS36-10 Series provides precise temperature control for optimum product quality and maximum throughput. Like conventional thermocouples, all IR thermocouples do not require external power and plug into your controller, PLC, datalogger, recorder or data acquisition system. They simply measure temperature without contact. The internal air purge passages provide a highly efficient method of maintaining optical cleanliness in harsh environments.
Range Code | Temperature Range (2% Accuracy) |
| 50F | -18 to 27°C (0 to 80°F) |
| 80F | 10 to 49°C (50 to 120°F) |
| 98.6F | 16 to 39°C (60 to 102°F) |
| 140F | 25 to 80°C (80 to 180°F) |
| 180F | 70 to 104°C (160 to 220°F) |
| 240F | 95 to 130°C (200 to 270°F) |
| 280F | 125 to 155°C (260 to 310°F) |
| 340F | 145 to 175°C (290 to 350°F) |
| 440F | 170 to 250°C (340 to 480°F) |
SPECIFICATIONS
Range: -45 to 1370°C (-50 to 2500°F)**
Field-of-View: 6° (10:1)
Minimum Spot Size: 20 mm (0.8")
Output Impedance: 4 to 8 kΩ (varies by model)
Operating Ambient Temperature Range: -18 to 85°C (0 to 185°F)
Air Purge: Built-in
Ambient Temperature Compensation: With air flow of 1.1 SCFM (20 psig) maximum ambient is 204°C (400°F)
Dimensions: 9.55 L x 3.49 cm Dia. (3.76 x 1.375"); 0.9 m (36") PFA coated lead wires
Weight: 184 g (6.5 oz) with cable
**See range chart for linear ranges. Measurement is practical
beyond thermocouple table values by use of radiation laws.
Polynomials available upon request.
|
| |
 |
|
|
MOST POPULAR MODELS HIGHLIGHTED! |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: Polynomials available upon request. 98.6F 16 to 39°C/60 to 102°F Stripped leads are standard. To order with GMP subminiature low-noise thermocouple connector pair, add suffix “-GMP” to model no. and add $12 to price. To order with GST standard size low-noise thermocouple connector pair, add suffix “-GST” to model no. and add $12 to price. (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) OS36-10-K-140F IR thermocouple sensor type K, with 26 to 82° C (80 to 180°F) range, $519.00
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Temperature Range
|
| |
Select 80F for 10 to 49°C/50 to 120°F 140F for 25 to 80°C/80 to 180°F 180F for 70 to 104°C/160 to 220°F 240F for 95 to 130°C/200 to 270°F 280F for 125 to 155°C/260 to 310°F 340F for 145 to 175°C/290 to 350°F 440F for 170 to 250°C/340 to 480°F
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
|
 |
|
|
 |
|
 |
|
Back to top
|