Insertion/Submersion Combination Electrodes
The PHE-7151 series combination electrodes are ruggedly constructed; the
outer body is ABS with 3/4" MNPT threads at both ends. The
maximum insertion length is 31.75 mm/1.25". Electrodes are
annular PTFE liquid junction refillable and include 15 ft of
cable with a BNC connector. For applications with
temperatures up to 120°C (248°F), units are available in
polyphenylene sulfide (PPS).***
These electrodes have a special plunger
design allowing them to be mounted at any angle.
Part No.
Length mm/in
Dia. mm/in
pH Range
Temp. °C
Refill or Gel
R (megohms) at 25°C/77°F
Description
PHE-7151-15
140/5.5
30/1.2
0 to 12
0 to 80
Refill
400
Refillable general purpose**
PHE-7351-15
140/5.5
30/1.2
0 to 12
0 to 80
Gel
400
Sealed general purpose
PHE-7152-15
140/5.5
30/1.2
0 to 14
0 to 80
Refill
1000
Refillable high pH applications**
ORE-7151-15
140/5.5
30/1.2
—
0 to 80
Refill
—
General purpose refillable ORP**
** Refill Solution: PHFS-7151-4, 4 oz bottle; PHFS-7151-16, 16 oz bottle
***For polyphenylene sulfide body, add suffix “-PPS” to part number and $50 to price
In-Line Disposable Electrodes
OMEGA® in-line combination electrodes mount on standard pipe tees for continuous pH or ORP
monitoring. The electrode is constructed in a PVDF housing with 1/2" MNPT threading. Probe insertion
length is 25 mm (1") and is able to withstand pressure up to 150 psi. Three-meter (10-ft.) cable
length and BNC connector are standard. Dimensions: 127 x 25 mm (5 x 10")
CPVC In-Line Disposable pH Electrodes
Also available, the CPVC In-Line Disposable Electrode is
ruggedly constructed to withstand up to 100 psi. Probe
insertion length is 51 mm (2") with 3/4" diameter. A 3/4" MNPT
fitting is standard and is supplied with 3 m (10 ft.) of cable
and a BNC connector. Dimensions: 168 x 25 mm (6.6 x 10")
Gold disc double junction for cyanide applications
—
B
PHE-5316-10
0 to 13
-5 to 80/23 to 176
Sealed Ag/AgCl
50
Automatic Temperature Compensation is not required with ORP (Redox) electrodes.
† All dollar amounts on this site are shown in US currency.
Note: PHE-7000 Series Combination Electrodes come complete with 4.5 m (15') of cable with BNC connector and electrode care instruction sheet.
PHE-5000 Series In-Line Disposable Electrodes come complete with 3 m (10') of cable with BNC connector and electrode care instruction sheet.
For non-standard cable lengths replace the "(-15) for the PHE-7000 Series or the "(-10)" for the PHE-5000 Series with the required cable length in feet; add $2 per foot to the price. (Additional per foot cost applies to the entire length of cable).
Automatic temperature compensation is not required with ORP electrodes.
Options for the PHE-7000 Series:
For HF/Fluoride Resistant electrode, add suffix "-HF" to model number, add $50 to price.
For polyphenylene sulfide body add suffix "-PPS" to model number; add $35 to price.
For high temperature reference cells, add suffix "-HT" to the model number, add $35 to price.
Note: "-PPS" and "-HT" options only available on the PHE-7351 and "-HT" option is only available in combination with PPS option on the PHE-7351 electrode.
For 100Ω Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT100" to the model number, add $50 to price.
For 1000Ω Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT1K" to model number, add $50 to price.