Sanitary RTD Sensors with Integral Cables
For use in Clean-In-Place Applications |
| PRS-CB Series Sanitary RTD Sensors |
|
 |
|
|
|
|
$
120.00
PRS-3-100-A-S-0600-D1-CB-120
|
| |
1/4" Diameter Probe Design for Standard Duty, or 3/8" to 3/16" Stepped Probe Design For Heavy Duty Applications
|
| |
Probe Lengths of 3", 4", 5" and 6" Available From Stock, Other Lengths Also Available
|
| |
1½"-16 AMP Tri-Grip (Tri-Clamp® Compatible) Fitting Standard, Other Sizes and Styles Available. Flanges Conform to ASME BPE-2007 Standard to Assure Trouble Free Interchangeability.
|
| |
Sensor Can be Used in Sanitary, Hygienic and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes
|
| |
316L SS Wetted Surfaces with 32 µinch or Better Surface Finish
|
| |
4-Conductor, 120" Long PFA Cable with Molded Nylon Strain Relief Standard
|
| |
-50 to 200°C (-58 to 392°F) Temperature Range
|
| |
4-Wire Pt100 Class A Platinum RTD Sensor (100.00±0.06Ω at 0°C) Standard
|
| |
Compatible with 3-Wire and 2-Wire RTD Instruments and Transmitters
|
|
View related products - Sensors and Transducers
|
|
|
|
 |
This Sanitary Temperature Sensor containes a PT100 Platinum RTD element and is designed for use in Food, Dairy, Beverage and BioPharmaceutical Clean-In-Place (CIP) type applications. The sensor includes a
1½" 16AMP mounting flange that conforms to ASME BPE-2007 for easy installation using industry standard
gaskets and clamps. Standard Duty sensors are available with ¼"
diameter probes, and Heavy Duty sensors are available with a stepped 3⁄8" to
3⁄16" diameter probe. This sensor is provided with a 120" long, 4-conductor, #26AWG
stranded nickel plated copper, PFA insulated and jacketed cable with
a strain relief for convenient connection to control or monitoring
equipment.
Sanitary Temperature Sensor Specifications Include:
316L stainless steel process wetted surfaces with surface finishes
of 32 microinches or better.
Probe lengths of 3, 4, 5 or 6 inches available from stock, other lengths available
as special orders.
Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting
the requirements of IEC 60751.
These sensors can be used with 2-wire or 3-wire systems see information below.
Insulation resistance: 100 megohms minimum at 100 VDC.
Thermal response time of less than 2.5 seconds in water flowing
at 3 ft/sec (63% response).
These sanitary sensors are supplied standard as 4-wire assemblies with two
red wires and two white wires. When used in 3-wire applications,
cut off one white wire making sure that it will not contact any terminals
or metal surfaces (note: twisting the two white wires together will reduce
the lead wire resistance on one side of the sensing element by half
adversely affecting the accuracy of the reading).
When used in 2-wire applications, cut off one white wire
and one red wire (note: in 2-wire applications, twisting the two
same-colored wires together at the terminals will not adversely
affect your sensor accuracy since both wires will be affected by
the reduction in resistance).
These sensors are also
available in Thermistor
and Thermocouple styles to accommodate any process input requirement. In addition to the
standard 1½-16AMP flange design, these can be provided
in a wide variety of flange sizes and styles. If you need something a
little (or a lot) different, we can accommodate your needs.
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: For standard duty probe lengths longer than 6", change "-0600" in model number to the required length (example: 12" = "-1200", 9¼" = "-0925") and add $1 per inch to the price (up to 24 inches).For heavy duty probe lengths longer than 6", change "-0600" in model number to the required length (example: 12" = "-1200", 9¼" = "-0925") and add $2.50 per inch to the price (up to 24 inches).For cable lengths longer than 10' (120"), change the "-120" in model number to the desired length in inches and add $1 per foot to the price. For other flange sizes or styles, or for probe lengths longer than 24 inches please contact Customer Service.
Ordering Example: (1) PRS-3-100-A-S-0400-D1-CB-120 Sanitary RTD sensor with 4-wire Pt100, Class A accuracy element, ¼" diameter probe 4" long with 1½", 16AMP mounting cap and integral 120 inch long, 4-conductor cable with strain relief = $120
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Nominal Element Resistance
|
| |
Select 100 for 100 ohm @ 0 C (standard) 1000 for 1 kohm @ 0 C
|
(2)
|
Probe Diameter
|
| |
Select S for Standard Duty 1/4 inch H for Heavy Duty 3/8 to 3/16 inch stepped probe
|
(3)
|
Probe Length
|
| |
Select 0300 for 3 inch length 0400 for 4 inch length 0500 for 5 inch length 0600 for 6 inch length
|
(4)
|
Sanitary Flange (Cap) Size
|
| |
Select D1 for 1-1/2 inch Tri-Grip Flange (standard) E1 for 2 inch Tri-Grip Flange
|
(5)
|
Lead Wire Cable Length
|
| |
Select 120 for 120 inch/10 ft (standard) 144 for 144 inch/12 ft 180 for 180 inch/15 ft 240 for 240 inch/20 ft
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
 |
 |
|
 |
|  |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Related Links -
Related Products
|
 |
 |
 |
 |
 |
 |
|
Related Products
|
|
 |
TA3 and TA4:
|
|
Miniature Connectors for RTD's and Thermistors Series "T"
|
 |
 |
|
|
|
 |
Temperature Controllers Product Finder:
|
|
Temperature Controllers Product Finder - It's the easiest way to sort through our selection of temperature controllers to find the right product for your application
|
 |
 |
|
 |
Meters Product Finder:
|
|
New Meters Product Finder - It's the easiest way to sort through our selection of meters to find the right product for your application
|
 |
 |
|
 |
Data Loggers Product Finder:
|
|
New Datalogger Product Finder - It's the easiest way to sort through our selection of dataloggers to find the right product for your application
|
 |
 |
|
 |
Handheld Meters Product Finder:
|
|
New Handhelds Product Finder - It's the easiest way to sort through our selection of handhelds to find the right product for your application
|
 |
 |
|
 |
Data Acquisition System Product Finder:
|
|
New Data Acquisition Product Finder - It's the easiest way to sort through our selection of data acquisition systems to find the right product for your application
|
 |
 |
|
|
|
 |
 |
|
|
Keywords:Hygienic Sensors Sanitary Sensors with Integral Cables clean-in-place CIP Pt100 Tri-Clamp Sanitary Temperature Sensors
|