Get all the great performance characteristics of the
Micro-Machined Silicon Transducers in these wet/wet
differential pressure models. These rugged stainless
steel transducers are ideal for tough industrial
automotive, or aerospace applications requiring a
wet/wet transducer. They can be used in test benches,
fitler monitoring, hydraulic, flow, or water/wastewater
applications, as well as factory or pneumatic air, pitot
tubes, air speed and other industrial or aerospace
applications. The solid state silicon core and all stainless
steel wetted parts will provide long, reliable service life
with excellent long term stability.
COMMON SPECIFICATIONS Accuracy: 0.08% BSL linearity, hysteresis and repeatability combined Minimum Resistance Between Transducer Body and Any Wire: 100 MΩ Operating Temperature: mV/V and 5 to 10 Vdc Output: -45 to 121°C (-49 to 250°F) mA Output: -45 to 115°C (-49 to 239°F) Compensated Temperature Range: 10 inH2O to 5 psi: -17 to 85°C (1 to 185°F) 15 to 1000 psi: -29 to 85°C (-20 to 185°F) Thermal Accuracy: Zero Span
% Span Shift over compensated temperature range 10 inH2O to 1 psi: ±1.00% ±1.00% 2.5 to 1000 psi: ±0.50% ±0.50% Pressure Cycles: 1 million minimum Long Term Stability (1-Year): ±0.1% FS typical Bandwidth: DC to 1 kHz typical Response Time: <1 ms CE Complient: Meets EN1326-1: 2006 for industrial locations Shock: 50 g, 11 ms, half-sine shock (under test) Vibration: ±20 g (under test) Wetted Parts: 316L stainless steel Line/Static Pressure: 500 psi max applied to both sides simultaneously Proof Pressure (Differential): 10 inH2O range = 10 times range
1 psi range = 6 times range
2.5 to 750 psi ranges = 4 times range
1000 psi range = 3 times range Hi Side Containment Pressure (Differential): Ranges 10 inH2O to 5 psi: to 1000 psi Ranges 15 to 1000 psi: to 3000 psi Pressure Ports: ¼NPT male Electrical Terminations: PX409: 2 m (6') cable PX409C: 2 m (6') cable with ½ NPT conduit thread PX419: Mini-DIN (mating connector included) PX429: Twist-lock, mating connector (sold separately) PX429 Mating Connector: PT06F10-6S Weight: 200 g (7 oz) max
UNI-DIRECTIONAL mV/V SPECIFICATIONS Output: 10 mV/V ratiometric Supply Voltage: 5 to 10 Vdc Current Draw: 5 mA @ 10 Vdc Input Impedance: 1000 to 5000 Ω Output Impedance: 5000 Ω ±10% typical Zero Balance: Ranges ≤ 1psi: ±1% typ (2% max) Ranges > 1psi: ±0.5% typ (1% max) Span Setting: Ranges ≤ 1psi: ±1% typ (2% max) Ranges > 1psi: ±0.5% typ (1% max)
UNI-DIRECTIONAL VOLTAGE OUTPUT SPECIFICATIONS Output Voltage/Supply Voltage: 0 to 5 Vdc/ 10 to 30 Vdc; 0 to 10 Vdc/15 to 30 Vdc (change "5V" to "10V" in model number) Current Draw: 10 mA max Maximum Current Output: 2 mA (= 2500 Ω min load resistance) Output Impedance: 100 Ω Zero Balance: Ranges > 1psi: ±0.5% typ (1% max) Ranges ≤ 1psi: ±1% typ (2% max) Span Setting: Ranges > 1psi: ±0.5% typ (1% max) Ranges ≤ 1psi: ±1% typ (2% max)
UNI-DIRECTIONAL mA SPECIFICATIONS Output: 4 to 20 mA Supply Voltage: 9 to 30 Vdc; [9 to 20 Vdc above 105°C (229°F)] Max Loop Resistance: (Vs-9) x 50 Ω Zero Balance: Ranges > 1psi: ±0.5% typ (1% max) Ranges ≤ 1psi: ±1% typ (2% max) Span Setting: Ranges > 1psi: ±0.5% typ (1% max) Ranges ≤ 1psi: ±1% typ (2% max)
Three Termination Styles are available: PX409 = 2 m (6ft) cable
PX419 = mini-DIN Connector PX429 = Twist-Lock connector
Still can't find the right model? Specify the perfect transducer for your application with this easy, step-by-step configurator.
† All dollar amounts on this site are shown in US currency.
Note: To order models with different electrical terminations, change model number to on of the following: PX409 = Cable Connection (featured in chart above) PX419 = mini-DIN Connection (mating connector provided) PX429 = Twist Lock Connector (mating connector sold separately) Additional Ranges Available See Part Number Builder (below) for the full selection of pressure ranges Ordering Example: (1) PX429-005DWU5V Wet/Wet 5 psi diff. pres. range, 0 to 5 Vdc output, twist-lock termination, (1) PT06F10-6S Mating twist-lock connector (sold separately) = $866.5
Part Number Builder
Option Descriptions
(1)
Electrical Termination
Select 09 for 2 m (6') cable 19 for mini-DIN 29 for Twist-Lock (mating connector sold separately)
(2)
Pressure Range (PSI)
Select 10W for 0-10 inH2O 001 for 1 psi 2.5 for 2.5 psi 005 for 0-5 psi 015 for 0-15 psi 030 for 0-30 psi 050 for 0-50 psi 100 for 0-100 psi 150 for 0-150 psi 250 for 0-250 psi 500 for 0-500 psi 750 for 0-750 psi 1.0K for 0-1000 psi
(3)
Units
Select DWU for Wet/Wet Differential Pressure DDU for Wet/Dry Differential Pressure
(4)
Output
Select V for 10 mV/V Output 5V for 0-5 Volt dc Output 10V for 0-10 Volt dc Output I for 4-20 mA Output
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
Keywords:Micro-Machined Silicon Transducers,
Wet/Wet Differential Differential Pressure
High Accuracy Transdcuer