The design of the thermostat ensures
high accuracy, small switching difference
(hysteresis) and a long service life. Because
of the high switching capacity of the
thermostat, heaters can usually be directly
connected and switched, without the need
for additional relays.
SPECIFICATIONS Explosion Proof to EN: LCIE (Laboratoire Central des Industries Electriques) Conformity Certificate: LCIE 01 ATEX 6074/2
LCIENo06 ATEX Q8011, IECExLCI 07.0021 Operating Voltage: AC: 250 V max DC: 100 V max Switching Capacity: 4 A: Resistive @ 250 VA 1 A: Ind. (cos j = 0.6) @ 250 Vac Service Life at Max Load: >100,000 cycles Sensor Element: Thermostatic bi-metal Contact Type (1-Pole): Opens with rising temperature Connection Cable: Si HF - JZ 3 x AWG 3 x 0.75 mm2 x 1 m (18 x 3.3') Housing: Aluminum, black anodized Mounting: Mounting bracket with M8 nut and DIN clip for 35 mm (1.4") DIN rail mounting
Specifications are subject to change
without notice. Suitability of this product
for its intended use and any associated
risks must be determined by the end
customer/buyer in its final application.
† All dollar amounts on this site are shown in US currency.