The design of the thermostat ensures
high accuracy, small switching difference
(hysteresis) and a long service life. Because
of the high switching capacity of the
thermostat, heaters can usually be directly
connected and switched, without the need
for additional relays.
SPECIFICATIONS
Explosion Proof to EN: LCIE (Laboratoire Central des Industries Electriques)
Conformity Certificate: LCIE 01 ATEX 6074/2
LCIENo06 ATEX Q8011, IECExLCI 07.0021
Operating Voltage:
AC: 250 V max
DC: 100 V max
Switching Capacity:
4 A: Resistive @ 250 VA
1 A: Ind. (cos j = 0.6) @ 250 Vac
Service Life at Max Load: >100,000 cycles
Sensor Element: Thermostatic bi-metal
Contact Type (1-Pole): Opens with rising temperature
Connection Cable: Si HF - JZ 3 x AWG 3 x 0.75 mm2 x 1 m (18 x 3.3')
Housing: Aluminum, black anodized
Mounting: Mounting bracket with M8 nut and DIN clip for 35 mm (1.4") DIN rail mounting