0.315" (0.8 cm) and 0.475" (1.2 cm) Diameter Round Cross-section
Single-End Terminal Tubular Heaters |
| STRI and STRS |
|
 |
|
|
|
|
|
$
29.00
STRI-1248/120V
|
| |
Style STRI • INCOLOY Sheath • 225 - 2,400 Watts • 120 and 240 Volt • 4 - 30 W/In2 • 1600°F (870° C) Maximum Sheath Temperature
|
| |
Style STRS • Steel Sheath • 150 - 2,725 Watts • 120 and 240 Volt • 3 - 20 W/In2 • 750°F (450°C) Maximum Sheath Temperature
|
View related products - Tubular Heaters
|
| |
|
|
|
 |
Syle STRI
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with
flange, screwplug, threaded fitting or other means of mounting.
ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in
many cases. Use slim elements to concentrate heat into a confined
area, taking up less space than a U-shaped element with terminals at each end.
.315" (8 mm) Diameter Round Cross-Section Single-End Terminal

| Watts |
Volts |
W/In2 |
Dimensions in (cm) |
INCOLOY Sheath Model No. |
Weight (Lb.) |
| Sheath A |
Heated B |
| 225 | 120 | 30 | 11 7/8 (30) | 7 1/8 (18) | STRI-1248/120V | 0.4 |
| 325 | 120 | 30 | 15 7/8 (40) | 11 1/8 (28) | STRI-1648/120V | 0.4 |
| 325 | 240 | 30 | 15 7/8 (40) | 11 1/8 (28) | STRI-1648/240V | 0.4 |
| 450 | 120 | 30 | 19 7/8 (50) | 15 1/8 (38) | STRI-2048/120V | 0.4 |
| 450 | 240 | 30 | 19 7/8 (50) | 15 1/8 (38) | STRI-2048/240V | 0.4 |
| 575 | 120 | 30 | 23 7/8 (60) | 19 1/8 (49) | STRI-2448/120V | 0.4 |
| 575 | 240 | 30 | 23 7/8 (60) | 19 1/8 (49) | STRI-2448/240V | 0.4 |
| 700 | 120 | 30 | 27 7/8 (70) | 23 1/8 (59) | STRI-2848/120V | 0.8 |
| 700 | 240 | 30 | 27 7/8 (70) | 23 1/8 (59) | STRI-2848/240V | 0.8 |
| 800 | 120 | 30 | 31 7/8 (80) | 27 1/8 (69) | STRI-3248/120V | 0.8 |
| 800 | 240 | 30 | 31 7/8 (80) | 27 1/8 (69) | STRI-3248/240V | 0.8 |
| 925 | 120 | 30 | 35 7/8 (91) | 31 1/8 (79) | STRI-3648/120V | 0.8 |
| 925 | 240 | 30 | 35 7/8 (91) | 31 1/8 (79) | STRI-3648/240V | 0.8 |
| 1,050 | 120 | 30 | 39 7/8 (101) | 35 1/8 (89) | STRI-4048/120V | 1 |
| 1,050 | 240 | 30 | 39 7/8 (101) | 35 1/8 (89) | STRI-4048/240V | 1 |
| 1,175 | 120 | 30 | 43 7/8 (111) | 39 1/8 (99) | STRI-4448/120V | 1 |
| 1,175 | 240 | 30 | 43 7/8 (111) | 39 1/8 (99) | STRI-4448/240V | 1 |
| 1,200 | 120 | 28 | 47 7/8 (122) | 43 1/8 (110) | STRI-4848/120V | 1 |
| 1,275 | 240 | 30 | 47 7/8 (122) | 43 1/8 (110) | STRI-4848/240V | 1 |
| 1,200 | 120 | 26 | 51 7/8 (132) | 47 1/8 (120) | STRI-5248/120V | 1.3 |
| 1,400 | 240 | 30 | 51 7/8 (132) | 47 1/8 (120) | STRI-5248/240V | 1.3 |
| 1,150 | 120 | 23 | 55 7/8 (142) | 51 1/8 (130) | STRI-5648/120V | 1.3 |
| 1,525 | 240 | 30 | 55 7/8 (142) | 51 1/8 (130) | STRI-5648/240V | 1.3 |
| 1,075 | 120 | 13.7 | 59 7/8 (152) | 55 1/8 (140) | STRI-6048/120V | 1.3 |
| 1,650 | 240 | 30 | 59 7/8 (152) | 55 1/8 (140) | STRI-6048/240V | 1.3 |
| 875 | 120 | 13 | 71 7/8 (183) | 67 1/8 (171) | STRI-7248/120V | 1.3 |
| 2,000 | 240 | 30 | 71 7/8 (183) | 67 1/8 (171) | STRI-7248/240V | 1.3 |
| 750 | 120 | 10 | 83 7/8 (213) | 79 1/8 (201) | STRI-8448/120V | 1.8 |
| 2,350 | 240 | 30 | 83 7/8 (213) | 79 1/8 (201) | STRI-8448/240V | 1.8 |
| 650 | 120 | 7 | 95 7/8 (243) | 91 1/8 (231) | STRI-9648/120V | 1.8 |
| 2,400 | 240 | 27 | 95 7/8 (243) | 91 1/8 (231) | STRI-9648/240V | 1.8 |
| 575 | 120 | 6 | 107 7/8 (274) | 103 1/8 (262) | STRI-10848/120V | 2.5 |
| 2,300 | 240 | 23 | 107 7/8 (274) | 103 1/8 (262) | STRI-10848/240V | 2.5 |
| 500 | 120 | 4 | 119 7/8 (304) | 115 1/8 (292) | STRI-12048/120V | 2.5 |
| 2,000 | 240 | 18 | 119 7/8 (304) | 115 1/8 (292) | STRI-12048/240V | 2.5 |
.475 Diameter (1.2cm) Round Cross-Section Single-Ended Terminals

| Watts |
Volts |
W/In2 |
Dimensions in (cm) |
INCOLOY Sheath Model No. |
Weight (Lb.) |
| Sheath A |
Heated B |
| 325 | 120 | 30 | 11 7/8 (30) | 7 3/16 (18) | STRI-1245/120 | 0.5 |
| 500 | 120 | 30 | 15 7/8 (40) | 11 3/16 (28) | STRI-1645/120 | 0.5 |
| 500 | 240 | 30 | 15 7/8 (40) | 11 3/16 (28) | STRI-1645/240 | 0.5 |
| 675 | 120 | 30 | 19 7/8 (50) | 15 3/16 (39) | STRI-2045/120 | 0.5 |
| 675 | 240 | 30 | 19 7/8 (50) | 15 3/16 (39) | STRI-2045/240 | 0.5 |
| 850 | 120 | 30 | 23 7/8 (60) | 19 3/16 (49) | STRI-2445/120 | 0.5 |
| 850 | 240 | 30 | 23 7/8 (60) | 19 3/16 (49) | STRI-2445/240 | 0.5 |
| 1025 | 120 | 30 | 27 7/8 (70) | 23 3/16 (59) | STRI-2845/120 | 1 |
| 1025 | 240 | 30 | 27 7/8 (70) | 23 3/16 (59) | STRI-2845/240 | 1 |
| 1225 | 120 | 30 | 31 7/8 (80) | 27 3/16 (69) | STRI-3245/120 | 1 |
| 1225 | 240 | 30 | 31 7/8 (80) | 27 3/16 (69) | STRI-3245/240 | 1 |
| 1400 | 120 | 30 | 35 7/8 (91) | 31 3/16 (79) | STRI-3645/120 | 1 |
| 1400 | 240 | 30 | 35 7/8 (91) | 31 3/16 (79) | STRI-3645/240 | 1 |
| 1575 | 120 | 30 | 39 7/8 (101) | 35 3/16 (89) | STRI-4045/120 | 1.3 |
| 1575 | 240 | 30 | 39 7/8 (101) | 35 3/16 (89) | STRI-4045/240 | 1.3 |
| 1750 | 120 | 30 | 43 7/8 (111) | 39 3/16 (100) | STRI-4445/120 | 1.3 |
| 1750 | 240 | 30 | 43 7/8 (111) | 39 3/16 (100) | STRI-4445/240 | 1.3 |
| 1575 | 120 | 25 | 47 7/8 (122) | 43 3/16 (110) | STRI-4845/120 | 1.3 |
| 1925 | 240 | 30 | 47 7/8 (122) | 43 3/16 (110) | STRI-4845/240 | 1.3 |
| 1450 | 120 | 21 | 51 7/8 (132) | 47 3/16 (120) | STRI-5245/120 | 1.8 |
| 2100 | 240 | 30 | 51 7/8 (132) | 47 3/16 (120) | STRI-5245/240 | 1.8 |
| 1325 | 120 | 17 | 55 7/8 (142) | 51 3/16 (130) | STRI-5645/120 | 1.8 |
| 2275 | 240 | 30 | 55 7/8 (142) | 51 3/16 (130) | STRI-5645/240 | 1.8 |
| 1225 | 120 | 15 | 59 7/8 (152) | 55 3/16 (140) | STRI-6045/120 | 1.8 |
| 2475 | 240 | 30 | 59 7/8 (152) | 55 3/16 (140) | STRI-6045/240 | 1.8 |
| 1000 | 120 | 10 | 71 7/8 (183) | 67 3/16 (171) | STRI-7245/120 | 1.8 |
| 3000 | 240 | 30 | 71 7/8 (183) | 67 3/16 (171) | STRI-7245/240 | 1.8 |
| 850 | 120 | 7 | 83 7/8 (231) | 79 3/16 (201) | STRI-8445/120 | 2.3 |
| 3400 | 240 | 29 | 83 7/8 (213) | 79 3/16 (201) | STRI-8445/240 | 2.3 |
| 750 | 120 | 6 | 95 7/8 (243) | 91 3/16 (231) | STRI-9645/120 | 3.3 |
| 3000 | 240 | 22 | 95 7/8 (243) | 91 3/16 (231) | STRI-9645/240 | 3.3 |
| 650 | 120 | 4 | 107 7/8 (274) | 103 3/16 (261) | STRI-10845/120 | 3.3 |
| 2600 | 240 | 17 | 107 7/8 (274) | 103 3/16 (261) | STRI-10845/240 | 3.3 |
| 575 | 120 | 3 | 119 7/8 (304) | 115 3/16 (292) | STRI-12045/120 | 3.3 |
| 2300 | 240 | 13 | 119 7/8 (304) | 115 3/16 (292) | STRI-12045/240 | 3.3 |
Syle STRS
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with
flange, screwplug, threaded fitting or other means of mounting.
ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in many cases. Use slim elements to
concentrate heat into a confined area, taking up less space than a U-shaped
element with terminals at each end.
.315" (8 mm) Diameter Round Cross-Section Single-End Terminal

| Watts |
Volts |
W/In2 |
Dimensions in (cm) |
Steel Sheath Model No. |
Weight (Lb.) |
| Sheath A |
Heated B |
| 150 | 120 | 20 | 11 7/8 (30) | 71/8 (18) | STRS-1248/120V | 0.4 |
| 225 | 120 | 20 | 15 7/8 (40) | 11 1/8 (28) | STRS-1648/120V | 0.4 |
| 225 | 240 | 20 | 15 7/8 (40) | 11 1/8 (28) | STRS-1648/240V | 0.4 |
| 300 | 120 | 20 | 19 7/8 (50) | 15 1/8 (38) | STRS-2048/120V | 0.4 |
| 300 | 240 | 20 | 19 7/8 (50) | 15 1/8 (38) | STRS-2048/240V | 0.4 |
| 375 | 120 | 20 | 23 7/8 (60) | 19 1/8 (49) | STRS-2448/120V | 0.4 |
| 375 | 240 | 20 | 23 7/8 (60) | 19 1/8 (49) | STRS-2448/240V | 0.4 |
| 450 | 120 | 20 | 27 7/8 (70) | 23 1/8 (59) | STRS-2848/120V | 0.8 |
| 450 | 240 | 20 | 27 7/8 (70) | 23 1/8 (59) | STRS-2848/240V | 0.8 |
| 550 | 120 | 20 | 31 7/8 (80) | 27 1/8 (69) | STRS-3248/120V | 0.8 |
| 550 | 240 | 20 | 31 7/8 (80) | 27 1/8 (69) | STRS-3248/240V | 0.8 |
| 625 | 120 | 20 | 35 7/8 (91) | 31 1/8 (79) | STRS-3648/120V | 0.8 |
| 625 | 240 | 20 | 35 7/8 (91) | 31 1/8 (79) | STRS-3648/240V | 0.8 |
| 700 | 120 | 20 | 39 7/8 (101) | 35 1/8 (89) | STRS-4048/120V | 1 |
| 700 | 240 | 20 | 39 7/8 (101) | 35 1/8 (89) | STRS-4048/240V | 1 |
| 775 | 120 | 20 | 43 7/8 (111) | 39 1/8 (99) | STRS-4448/120V | 1 |
| 775 | 240 | 20 | 43 7/8 (111) | 39 1/8 (99) | STRS-4448/240V | 1 |
| 850 | 120 | 20 | 47 7/8 (122) | 43 1/8 (110) | STRS-4848/120V | 1 |
| 850 | 240 | 20 | 47 7/8 (122) | 43 1/8 (110) | STRS-4848/240V | 1 |
| 925 | 120 | 20 | 51 7/8 (132) | 47 1/8 (120) | STRS-5248/120V | 1.3 |
| 925 | 240 | 20 | 51 7/8 (132) | 47 1/8 (120) | STRS-5248/240V | 1.3 |
| 1025 | 120 | 20 | 55 7/8 (142) | 51 1/8 (130) | STRS-5648/120V | 1.3 |
| 1025 | 240 | 20 | 55 7/8 (142) | 51 1/8 (130) | STRS-5648/240V | 1.3 |
| 1075 | 120 | 19.7 | 59 7/8 (152) | 55 1/8 (140) | STRS-6048/120V | 1.3 |
| 1100 | 240 | 20 | 59 7/8 (152) | 55 1/8 (140) | STRS-6048/240V | 1.3 |
| 875 | 120 | 13 | 71 7/8 (183) | 67 1/8 (171) | STRS-7248/120V | 1.3 |
| 1325 | 240 | 20 | 71 7/8 (183) | 67 1/8 (171) | STRS-7248/240V | 1.3 |
| 750 | 120 | 10 | 83 7/8 (213) | 79 1/8 (201) | STRS-8448/120V | 1.8 |
| 1575 | 240 | 20 | 83 7/8 (213) | 79 1/8 (201) | STRS-8448/240V | 1.8 |
| 650 | 120 | 7 | 95 7/8 (243) | 91 1/8 (231) | STRS-9648/120V | 1.8 |
| 1800 | 240 | 20 | 95 7/8 (243) | 91 1/8 (231) | STRS-9648/240V | 1.8 |
| 575 | 120 | 6 | 107 7/8 (274) | 103 1/8 (262) | STRS-10848/120V | 2.5 |
| 2050 | 240 | 20 | 107 7/8 (274) | 103 1/8 (262) | STRS-10848/240V | 2.5 |
| 500 | 120 | 4 | 119 7/8 (304) | 115 1/8 (292) | STRS-12048/120V | 2.5 |
| 2000 | 240 | 13 | 119 7/8 (304) | 115 1/8 (292) | STRS-12048/240V | 2.5 |
.475" (12 mm) Diameter Round Cross-Section Single-End Terminal

| Watts |
Volts |
W/In2 |
Dimensions in (cm) |
Steel Sheath Model No. |
Weight (Lb.) |
| Sheath A |
Heated B |
| 200 | 120 | 20 | 11 7/8 (30) | 7 3/16 (18) | STRS-1245/120V | 0.5 |
| 325 | 120 | 20 | 15 7/8 (40) | 11 3/16 (28) | STRS-1645/120V | 0.5 |
| 325 | 240 | 20 | 15 7/8 (40) | 11 3/16 (28) | STRS-1645/240V | 0.5 |
| 450 | 120 | 20 | 19 7/8 (50) | 15 3/16 (38) | STRS-2045/120V | 0.5 |
| 450 | 240 | 20 | 19 7/8 (50) | 15 3/16 (38) | STRS-2045/240V | 0.5 |
| 575 | 120 | 20 | 23 7/8 (60) | 19 3/16 (49) | STRS-2445/120V | 0.5 |
| 575 | 240 | 20 | 23 7/8 (60) | 19 3/16 (49) | STRS-2445/240V | 0.5 |
| 700 | 120 | 20 | 27 7/8 (70) | 23 3/16 (59) | STRS-2845/120V | 1 |
| 700 | 240 | 20 | 27 7/8 (70) | 23 3/16 (59) | STRS-2845/240V | 1 |
| 800 | 120 | 20 | 31 7/8 (80) | 27 3/16 (69) | STRS-3245/120V | 1 |
| 800 | 240 | 20 | 31 7/8 (80) | 27 3/16 (69) | STRS-3245/240V | 1 |
| 925 | 120 | 20 | 35 7/8 (91) | 31 3/16 (79) | STRS-3645/120V | 1 |
| 925 | 240 | 20 | 35 7/8 (91) | 31 3/16 (79) | STRS-3645/240V | 1 |
| 1050 | 120 | 20 | 39 7/8 (101) | 35 3/16 (89) | STRS-4045/120V | 1.3 |
| 1050 | 240 | 20 | 39 7/8 (101) | 35 3/16 (89) | STRS-4045/240V | 1.3 |
| 1175 | 120 | 20 | 43 7/8 (111) | 39 3/16 (99) | STRS-4445/120V | 1.3 |
| 1175 | 240 | 20 | 43 7/8 (111) | 39 3/16 (99) | STRS-4445/240V | 1.3 |
| 1275 | 120 | 20 | 47 7/8 (122) | 43 3/16 (110) | STRS-4845/120V | 1.3 |
| 1275 | 240 | 20 | 47 7/8 (122) | 43 3/16 (110) | STRS-4845/240V | 1.3 |
| 1400 | 120 | 20 | 51 7/8 (132) | 47 3/16 (120) | STRS-5245/120V | 1.8 |
| 1400 | 240 | 20 | 51 7/8 (132) | 47 3/16 (120) | STRS-5245/240V | 1.8 |
| 1325 | 120 | 17 | 55 7/8 (142) | 51 3/16 (130) | STRS-5645/120V | 1.8 |
| 1525 | 240 | 20 | 55 7/8 (142) | 51 3/16 (130) | STRS-5645/240V | 1.8 |
| 1225 | 120 | 15 | 59 7/8 (152) | 55 3/16 (140) | STRS-6045/120V | 1.8 |
| 1650 | 240 | 20 | 59 7/8 (152) | 55 3/16 (140) | STRS-6045/240V | 1.8 |
| 1000 | 120 | 10 | 71 7/8 (183) | 67 3/16 (171) | STRS-7245/120V | 1.8 |
| 2000 | 240 | 20 | 71 7/8 (183) | 67 3/16 (171) | STRS-7245/240V | 1.8 |
| 850 | 120 | 7 | 83 7/8 (231) | 79 3/16 (201) | STRS-8445/120V | 2.3 |
| 2350 | 240 | 20 | 83 7/8 (213) | 79 3/16 (201) | STRS-8445/240V | 2.3 |
| 750 | 120 | 6 | 95 7/8 (243) | 91 3/16 (231) | STRS-9645/120V | 3.3 |
| 2725 | 240 | 20 | 95 7/8 (243) | 91 3/16 (231) | STRS-9645/240V | 3.3 |
| 650 | 120 | 4 | 107 7/8 (274) | 103 3/16 (262) | STRS-10845/120V | 3.3 |
| 2600 | 240 | 17 | 107 7/8 (274) | 103 3/16 (262) | STRS-10845/240V | 3.3 |
| 575 | 120 | 3 | 119 7/8 (304) | 115 3/16 (292) | STRS-12045/120V | 3.3 |
| 2300 | 240 | 13 | 119 7/8 (304) | 115 3/16 (292) | STRS-12045/240V | 3.3 |
If element is to be bent, specify "must be annealed".
|
| |
 |
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: When used as an immersion heater, specify “sealed end”.
Ordering Example: (1) STRS-5248/120V 925 Watt, 120 Volt Heater, $112
|
|
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Style
|
| |
Select STRI for style STRI STRS for style STRS
|
(2)
|
Code in Part Number
|
| |
Select 12 for code 12 16 for code 16 20 for code 20 24 for code 24 28 for code 28 32 for code 32 36 for code 36 40 for code 40 44 for code 44 48 for code 48 52 for code 52 56 for code 56 60 for code 60 72 for code 72 84 for code 84 96 for code 96 108 for code 108 120 for code 120
|
(3)
|
Code in Part Number
|
| |
Select 45 for code 45 48 for code 48
|
(4)
|
Voltage
|
| |
Select 120V for 120 V 480V for 480 V
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
 |
|
|
 |
|  |
|
Keywords:0.315 Inch(8mm) Diameter Round Cross-Section Single-End Terminal, Tubular Heater
0.315" (0.8 cm) and 0.475" (1.2 cm) Diameter Round Cross-section
Single-End Terminal Tubular Heaters
|
Back to top
|
|