Omega’s new USB-TC Series of
thermocouple probes with direct
USB connection feature a rugged
transition joint construction, 2 m (6')
of shielded output cable and free
user software that converts your PC
into a temperature meter, chart
recorder or data logger. Probes are
available off-the-shelf in 18 or 24"
lengths and with 0.187 or 0.250"
304 stainless steel, Inconel or high
performance Super OMEGACLAD
XL® sheathing.
SPECIFICATIONS
Integral Thermocouple: Type- K
(ungrounded)
Measurement Range:
K1: -73 to 315°C (-100 to 600°F)
K2: -270 to 1000°C (-454 to 1832°F)
NOTE: For 304 stainless steel max temperature is 850°C (1562°F)
Accuracy:
K1: ±1°C (1.8°F)
K2: ±2°C (3.6°F)
Resolution:
USB-TC-K1: 0.1°; USB-TC-K2: 1°
Stability:
USB-TC-K1: ±0.25°C,
USB-TC-K2: ±0.5°
Cold Junction Compensation (Automatic): -10 to 70°C
Operating Environment (Cold End):
-10 to 70°C, 0-95% relative humidity
(non-condensing)
PC Interface: USB
USB Cable: Integral to probe, 2 m (6')
(shielded) Type A plug
Software (Included): Requires Windows
2000, XP, or Vista operating system
Weight: 70 g (2.5 oz)
|
 |
|
 |
† All dollar amounts on this site are shown in US currency.
Note: *Insert “316” for 4.5 mm (0.187" diameter sheath) or “14” for 6 mm (0.250" diameter sheath). **Insert “18” for 457 mm (18" probe length) or “24” for 610 mm (24" probe length).
Ordering Example: (1) TJ-USB-CASS-14-24-K1 heavy duty USB TJ probe, 304 SS sheath, 6 mm (1.4") OD, 610 mm (24") long with integral USB cable and Type A connector, -73 to 315°C (-100 to 600°F) temperature range = $95
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Probe Material
|
| |
Select CASS for 304 stainless steel CAIN for inconel KQXL for Nickel Chrome(Super OMEGACLAD XL®
|
(2)
|
Probe Diameter
|
| |
Select 316 for 4.5mm(3/16 inch) 14 for 6mm(1/4 inch)
|
(3)
|
Probe Length
|
| |
Select 18 for 457mm(18 inches) 24 for 610mm(24 inches)
|
(4)
|
Temperature Range Code
|
| |
Select K1 for -73 to 315°(-100 to 600°F) K2 for -200 to 850°C (-328 to 1562°F) with stainless steel probe OR -200 to 1000°C (-328 to 1832°F) with inconel or nickel-chrome probe
|
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
 |
 |
|
 |
|  |
|
Back to top |
|
|