FEATURES
Heavy coil construction— Watt density on the heating coil is designed for low watt density
operation by increasing the coil diameter and length to give maximum
coil surface area and limit coil surface temperature, providing longer coil life.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or
installed or used by non-qualified personnel. See inside back cover
for additional warning.
6 Inch-150 Lb. steel Flange, 12 Cooper Sheath Elements — 15 W/in2
12
2-3
25 1/8 (64)
67 (30)
TMO-1212F1/**/3P
1 (3)
TMO-1212F1E3/**/3P
1 1/2 (4)
TMO-1212F1E4/**/3P
1 1/2 (4)
16
2-3
33 (84)
76 (34)
TMO-1216F1/**/3P
1 (3)
TMO-1216F1E3/**/3P
1 1/2 (4)
TMO-1216F1E4/**/3P
1 1/2 (4)
20
2-3
40 1/2 (103)
84 (38)
TMO-1220F1/240/3P
2 (5)
TMO-1220F1E3/240/3P
1 1/2 (4)
TMO-1220F1E4/240/3P
1 1/2 (4)
20
2-3
40 1/2 (103)
84 (38)
TMO-1220F1/480/3P
1 (3)
TMO-1220F1E3/480/3P
1 1/2 (4)
TMO-1220F1E4/480/3P
1 1/2 (4)
24
2-3
48 (122)
111 (50)
TMO-1224F1/240/3P
2 (5)
TMO-1224F1E3/240/3P
1 1/2 (4)
TMO-1224F1E4/240/3P
1 1/2 (4)
24
2-3
48 (122)
111 (50)
TMO-1224F1/480/3P
1 (3)
TMO-1224F1E3/480/3P
1 1/2 (4)
TMO-1224F1E4/480/3P
1 1/2 (4)
/* Add the suffix “/3P” to the catalog number for 3 phase power.
/** Designate voltage, i.e., 240 for 240 VAC or 480 for 480 VAC.
Note: Larger flange sizes and kW rating available. Contact Omegalux®
1 Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified.
2 Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
When using the Part Number Builder some part number combinations may not be valid!
Please review the tables and spec sheet for valid part numbers, or consult with Temperature Engineering
if you need help selecting a heater or to verify part number validity or availability!
† All dollar amounts on this site are shown in US currency.
Part Number Builder
Option Descriptions
(1)
Code in Part Number
Select 1212 for code 1212 1216 for code 1216 1220 for code 1220 1224 for code 1224 30315 for code 30315 30415 for code 30415 30615 for code 30615 60825 for code 60825 61025 for code 61025 61225 for code 61225 61525 for code 61525 61825 for code 61825
(2)
Code in Part Number
Select Nothing(leave field blank) F1 for code F1
(3)
Enclosure
Select Nothing(leave field blank) for E1 General Purpose Enclosure E2 for E2 Moisture Resistant/Explosion Res.Encl E3 for E3 Explosion Res. Encl E4 for E4 Moisture Res.Encl
(4)
Voltage
Select 240V for 240 V 480V for 480 V
(5)
Power
Select Nothing(leave field blank) /3P for 3 phase power
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.